Newcon Optik LAM 3 IR - page 1
Operation Ma nual LAM 3 IR RED / INFRARED LASER AIMER / ILLUMINATOR 105 Sparks Ave., Toronto, ON M2H 2S5, Canada ...
-
Newcon Optik LAM 3 IR - page 2
ii LASER RADIATION –AVOID EXPOSURE TO THE BEAM INFRARED LASER OUTPUT POWER <25 mW WAVELENGTH 830-860 nm RED LASER OUTPUT POWER <8 mW WAVELENGTH 630-660 nm CLASS 3B LASER PRODUCT LASER WARNING LABEL IS LOCATED ON TOP OF THE DEVICE ...
-
Newcon Optik LAM 3 IR - page 3
iii IMPORTANT INFORMATION Read prior to activation You have ju st purchased a sophisticat ed electronic de vice. To operate it properly, please read this manual carefully. LAM belongs t o Class 3b lase r products i n accordance with IEC 6 0825-1. This radiation is hazardous for your eyes. Here are some comm on precautions t hat must be observed. Av ...
-
Newcon Optik LAM 3 IR - page 4
iv NEVER reverse polarity of the battery ALWAYS make sure that the device i s fixed firml y on the weapon ALWAYS remove battery whe n not in use fo r a long period ALWAYS store in a warm dry place when not in use ALWAYS clea n output windows wi th soft c loth only ALWAYS check t he O-ring when repl acing the battery. ...
-
Newcon Optik LAM 3 IR - page 5
1 CONTENTS 1. Brief description ..........................................................2 1. LAM DESIGN AND APPEAR ANCE ........................ 3 2. DELIVERY S ET ......................................................... 9 2.1 Standard deliv ery set ................................... 9 3. SPECIFICATION S ........................................ ...
-
Newcon Optik LAM 3 IR - page 6
2 Carefully read all the instructions prior to use. Failure to obey the instructions will void the warranty ! INVISIBLE LASER RADIAT ION CLASS 3B LASER PRODUCT 830–860 nm 25 mW, 630-650 nm 8 mW. DON’T LOOK INTO THE BEAM! 1. Brief description LAM laser aimer/illuminator (hereinafter referred as LAM) is desi gned for precise aiming at day and nig ...
-
Newcon Optik LAM 3 IR - page 7
3 1. LAM 3IR APPEARANCE Fig. 1 — Front view 1 - Windage and elevation adjustment knobs, for Visible & IR aimer channel 2 - Windage and elevation adjustment knobs, for illuminator channel 3 – Housing 4 - IR ai mer 5 - Visible red aimer 6 - Battery compart ment cover 7 – Illuminator 8 - Illuminator beam divergence adjustment ring 9 - Quick ...
-
Newcon Optik LAM 3 IR - page 8
4 Fig. 2 — LAM rear view 11 - Bracket 12 - blocking ri ng 13 - mode s witch 14 - low battery indicator 15 – hig h / low (wor king / t raining m odes) power s witch 16 - remote button conn ector 17 - windage adjustment knob, illuminator channel 11 17 16 15 14 13 12 ...
-
Newcon Optik LAM 3 IR - page 9
5 LAM consists of three laser emitters – IR aimer (4, Fig. 1), visible aimer (5, Fig.1) and IR illuminator (7, Fig. 1) – comb ined in o ne h ous ing (3 , Fi g. 1 ) w ith i nter axis distance of 44.8 millimeters. LAM is powered by a lithium battery (CR123 type). Th e battery is installed between aimer and illuminator and covered with battery com ...
-
Newcon Optik LAM 3 IR - page 10
6 OFF LAM is off R Visible aimer is on P IR aimer is on IL Illuminator is on ILP Both IR aimer and Illuminator are on BT Battery test The LED (14, Fig. 2) in BT mode indicates bat tery level: solid red LED means the battery charge is normal, if it is blinking - the batte ry must be replace d. IR channels of LAM can ope rate at high (H m ode) and lo ...
-
Newcon Optik LAM 3 IR - page 11
7 High power mode is a health hazard! Lock switch (15, Fig.2) with blo cking ring (12, Fig.2) when you do not intend using LAM in high power mode. Use filter with the Red Channel in the training mode LAM can be turned on either w ith a switch (13, Fig. 2) or with a remote control pressure switch, when it is connected through the remote control conn ...
-
Newcon Optik LAM 3 IR - page 12
8 points (de pending on t he locati on of LAM on t he weapon). For precise shooting you sho uld know the distance to the target and ha ve trajectory correction t able for your weapon. The shooter shou ld estimate the distance and determine the s hift of the aim er spot in acc ordance with the correction table. Use illuminator when light cond itions ...
-
Newcon Optik LAM 3 IR - page 13
9 2. DELIVERY SET Standard delivery set Quantity Laser aimer / illuminator LAM 3 IR with mount 1 Remote pressure switch 1 O-Ring 1 Soft case 1 Manual 1 Warranty card 1 ...
-
Newcon Optik LAM 3 IR - page 14
10 3. SPECIFICATIONS Aimer V IR Illuminator Laser wavelength 635 ± 10 nm 830-860 nm 830- 860 nm Beam divergence 0.4 mrad (1’) 0.9-80 mrad (3’...4°30’) Power of laser emission, L mode H mode 0.24 mW 10% with filter 25 mW 10% 2 mW 10% 25 mW 10% 2 mW 10% Windage / elevation adjustment range ± 20 mrad (±1°10’) Adjustmen ...
-
Newcon Optik LAM 3 IR - page 15
11 4. OPERATION INSTRUCTIONS DANGER! THIS LASER EQUIPMENT IS HAZARDOUS FOR YO UR EYES! Do not look into laser beam with naked eyes or through any optical device. Do not point an active unit at highly reflective surfaces or towards other indivi duals or animals. Battery installation Ensure the m ode switch (13, Fig. 2) is in OF F positio ...
-
Newcon Optik LAM 3 IR - page 16
12 Mounting LA M on a weapon Mount LAM on the Picatinny rail u sing the quick release lever mount (9, Fig. 1) so that the laser emission is directed towards the target; If desired, connect the remote switch cable to the connector (16, Fig. 2) a nd tighten t he nut. Fix t he remote switch on the weapon pivot or gr ip by Velcro tape in place, ...
-
Newcon Optik LAM 3 IR - page 17
13 1. Mount LAM on the weapo n. 2. Fix the weapon in the aiming rest. 3. Insert the laser bore sight into the barrel. 4. Zero the bore sight in accordance with its operation manual. 5. Set the target at the distance, required for th is weapon and this target. 6. Activate LAM in ILP mode. 7. Set minimal divergence of the illuminato r channel. 8. Set ...
-
Newcon Optik LAM 3 IR - page 18
14 4. Set the minimal divergence of the illuminator channel. 5. Superpose ce nters of the sp ots produced by the aimer and illuminator on the aiming mark by rotating adjustment knobs (1, Fig. 1), (1 7, Fig. 2). 6. Fire the we apon. 7. If point of impact is off the aiming m ark adjust windage and el evation by r otating adjustm ent knobs (1, Fig. 1) ...
-
Newcon Optik LAM 3 IR - page 19
15 Preparing LAM for transpo rtation 1. Turn LAM off by turning operating modes switch (13, Fig. 2) to OFF position. 2. Disconnect the remote switch from the weapon. 3. Loosen quick release lever (9, Fi g.1), remove LAM from Picat inny rail. 4. Pack LAM and remote switch into the case ...
-
Newcon Optik LAM 3 IR - page 20
16 5. CARE, STORAGE AND TRANSPORTA TION General LAM is a sophisticated precise optical in strument equipped with electronics. Ther efore, it should be handled with due care. - Never disassem ble LAM. - Keep away from direct sunlight, im pacts, dust, moisture, and sharp cha nges of temperature. - Do not store LAM at tem peratures higher than 70 o C ...
-
Newcon Optik LAM 3 IR - page 21
17 If LAM was exposed to salt water it should be rinsed in fresh water a nd dried outside at n o more than 55 o C. Long-term storage When preparing for long-term storage, cover the exte rnal metal surfaces of LAM with pr otective lubricant. Eac h 4 (four) years old layer of lubri cant should be removed a nd new layer be applied. To remove ol d laye ...
-
Newcon Optik LAM 3 IR - page 22
18 2. When preparin g for a long- term storage LA M just received from manufacture r or from workshop ensure that actual set is the same as indicated in the Delivery Set section of this manual. 3. Cases with units shoul d be placed on stands, shelves or in cupboards in dry heated and v entilated premises in accordance with Stora ge conditions as de ...
-
Newcon Optik LAM 3 IR - page 23
19 8. Presence of acid and alkaline vapor, as well as of other aggressi ve admixtures i n the air i n the storage area may cause damage to L AM. 9. After 4 years of storage, it is necessary to perform thorough inspection of units’ functionality. Transporta tion When packed, LAMs ca n be transported by any covered means in accordance with Storage ...
-
Newcon Optik LAM 3 IR - page 24
20 6. TROUBLESHOOTING The LED indicator is off when switch is ON. Turn the switch on again. If LAM still does not go ON check that battery is installe d properly and has sufficient charge. Replace battery if necessary. Spot shape or size has chan ged Emitter objective lens is dirty. Flush emitter lens with fresh water and wipe it with soft cloth. I ...
-
Newcon Optik LAM 3 IR - page 25
21 7. WARRANTY NEWCON warrants this product against defects in material and workmanship for one year from the date o f the original purchase. Longe r warranty is available, subject to the terms of the specific sales contract. Should your Newcon pr oduct prove to be defecti ve during this period, please deliver the produc t securely packaged in its ...
-
Newcon Optik LAM 3 IR - page 26
22 Postage, insura nce, and ship ping costs i ncurred whi le presenting your NEWCON p roduct for w arranty service are your responsibility. If shipping from North America please incl ude a cheque or money or der payabl e to NEWCON OPTIK fo r the amount of $15.00 to cover handling a nd retu rn shipping . ...
-
Newcon Optik LAM 3 IR - page 27
23 8. CUSTOMER SUPPORT Should you experience an y difficulties with your NEWCON OP TIK product , consult t he enclosed m anual. If the problem remains unreso lved, contact our customer support department at ( 416) 663-6963 or toll free at 1- 877-368-6666 . Our oper ating hours ar e 9am-5pm, Monday - Friday, Eastern Standard Time. At no tim e should ...
-
Newcon Optik LAM 3 IR - page 28
24 10. QUALITY CERTIFICATE LAM 3 IR seri al number_______ ____________ __________ complies wit h all technical specifi cations and has passed the inspection. Date of pr oduction: _____________ ____________ ________ Quality Inspector: _____________ ____________ _________ Quality Assurance Seal ...
-
Newcon Optik LAM 3 IR - page 29
25 ...
-
Newcon Optik LAM 3 IR - page 30
26 ...
-
Newcon Optik LAM 3 IR - page 31
27 ...
-
Newcon Optik LAM 3 IR - page 32
NEWCON OPTIK M065-24/A/XII R1.I – 8.11 ...
Haben Sie eine Frage bezüglich Newcon Optik LAM 3 IR?
Nutzen Sie das untere Formular
Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Newcon Optik LAM 3 IR nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Newcon Optik LAM 3 IR hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.