Manual Newcon Optik LAM 3 IR

32 pages 0.66 mb
Download

Go to site of 32

Summary
  • Newcon Optik LAM 3 IR - page 1

    Operation Ma nual LAM 3 IR RED / INFRARED LASER AIMER / ILLUMINATOR 105 Sparks Ave., Toronto, ON M2H 2S5, Canada ...

  • Newcon Optik LAM 3 IR - page 2

    ii LASER RADIATION –AVOID EXPOSURE TO THE BEAM INFRARED LASER OUTPUT POWER <25 mW WAVELENGTH 830-860 nm RED LASER OUTPUT POWER <8 mW WAVELENGTH 630-660 nm CLASS 3B LASER PRODUCT LASER WARNING LABEL IS LOCATED ON TOP OF THE DEVICE ...

  • Newcon Optik LAM 3 IR - page 3

    iii IMPORTANT INFORMATION Read prior to activation You have ju st purchased a sophisticat ed electronic de vice. To operate it properly, please read this manual carefully. LAM belongs t o Class 3b lase r products i n accordance with IEC 6 0825-1. This radiation is hazardous for your eyes. Here are some comm on precautions t hat must be observed. Av ...

  • Newcon Optik LAM 3 IR - page 4

    iv  NEVER reverse polarity of the battery  ALWAYS make sure that the device i s fixed firml y on the weapon  ALWAYS remove battery whe n not in use fo r a long period  ALWAYS store in a warm dry place when not in use  ALWAYS clea n output windows wi th soft c loth only  ALWAYS check t he O-ring when repl acing the battery. ...

  • Newcon Optik LAM 3 IR - page 5

    1 CONTENTS 1. Brief description ..........................................................2 1. LAM DESIGN AND APPEAR ANCE ........................ 3 2. DELIVERY S ET ......................................................... 9 2.1 Standard deliv ery set ................................... 9 3. SPECIFICATION S ........................................ ...

  • Newcon Optik LAM 3 IR - page 6

    2 Carefully read all the instructions prior to use. Failure to obey the instructions will void the warranty ! INVISIBLE LASER RADIAT ION CLASS 3B LASER PRODUCT 830–860 nm 25 mW, 630-650 nm 8 mW. DON’T LOOK INTO THE BEAM! 1. Brief description LAM laser aimer/illuminator (hereinafter referred as LAM) is desi gned for precise aiming at day and nig ...

  • Newcon Optik LAM 3 IR - page 7

    3 1. LAM 3IR APPEARANCE Fig. 1 — Front view 1 - Windage and elevation adjustment knobs, for Visible & IR aimer channel 2 - Windage and elevation adjustment knobs, for illuminator channel 3 – Housing 4 - IR ai mer 5 - Visible red aimer 6 - Battery compart ment cover 7 – Illuminator 8 - Illuminator beam divergence adjustment ring 9 - Quick ...

  • Newcon Optik LAM 3 IR - page 8

    4 Fig. 2 — LAM rear view 11 - Bracket 12 - blocking ri ng 13 - mode s witch 14 - low battery indicator 15 – hig h / low (wor king / t raining m odes) power s witch 16 - remote button conn ector 17 - windage adjustment knob, illuminator channel 11 17 16 15 14 13 12 ...

  • Newcon Optik LAM 3 IR - page 9

    5 LAM consists of three laser emitters – IR aimer (4, Fig. 1), visible aimer (5, Fig.1) and IR illuminator (7, Fig. 1) – comb ined in o ne h ous ing (3 , Fi g. 1 ) w ith i nter axis distance of 44.8 millimeters. LAM is powered by a lithium battery (CR123 type). Th e battery is installed between aimer and illuminator and covered with battery com ...

  • Newcon Optik LAM 3 IR - page 10

    6 OFF LAM is off R Visible aimer is on P IR aimer is on IL Illuminator is on ILP Both IR aimer and Illuminator are on BT Battery test The LED (14, Fig. 2) in BT mode indicates bat tery level: solid red LED means the battery charge is normal, if it is blinking - the batte ry must be replace d. IR channels of LAM can ope rate at high (H m ode) and lo ...

  • Newcon Optik LAM 3 IR - page 11

    7 High power mode is a health hazard! Lock switch (15, Fig.2) with blo cking ring (12, Fig.2) when you do not intend using LAM in high power mode. Use filter with the Red Channel in the training mode LAM can be turned on either w ith a switch (13, Fig. 2) or with a remote control pressure switch, when it is connected through the remote control conn ...

  • Newcon Optik LAM 3 IR - page 12

    8 points (de pending on t he locati on of LAM on t he weapon). For precise shooting you sho uld know the distance to the target and ha ve trajectory correction t able for your weapon. The shooter shou ld estimate the distance and determine the s hift of the aim er spot in acc ordance with the correction table. Use illuminator when light cond itions ...

  • Newcon Optik LAM 3 IR - page 13

    9 2. DELIVERY SET Standard delivery set Quantity Laser aimer / illuminator LAM 3 IR with mount 1 Remote pressure switch 1 O-Ring 1 Soft case 1 Manual 1 Warranty card 1 ...

  • Newcon Optik LAM 3 IR - page 14

    10 3. SPECIFICATIONS Aimer V IR Illuminator Laser wavelength 635 ± 10 nm 830-860 nm 830- 860 nm Beam divergence 0.4 mrad (1’) 0.9-80 mrad (3’...4°30’) Power of laser emission, L mode H mode 0.24 mW  10% with filter 25 mW  10% 2 mW  10% 25 mW  10% 2 mW  10% Windage / elevation adjustment range ± 20 mrad (±1°10’) Adjustmen ...

  • Newcon Optik LAM 3 IR - page 15

    11 4. OPERATION INSTRUCTIONS DANGER! THIS LASER EQUIPMENT IS HAZARDOUS FOR YO UR EYES!  Do not look into laser beam with naked eyes or through any optical device.  Do not point an active unit at highly reflective surfaces or towards other indivi duals or animals. Battery installation  Ensure the m ode switch (13, Fig. 2) is in OF F positio ...

  • Newcon Optik LAM 3 IR - page 16

    12 Mounting LA M on a weapon  Mount LAM on the Picatinny rail u sing the quick release lever mount (9, Fig. 1) so that the laser emission is directed towards the target;  If desired, connect the remote switch cable to the connector (16, Fig. 2) a nd tighten t he nut. Fix t he remote switch on the weapon pivot or gr ip by Velcro tape in place, ...

  • Newcon Optik LAM 3 IR - page 17

    13 1. Mount LAM on the weapo n. 2. Fix the weapon in the aiming rest. 3. Insert the laser bore sight into the barrel. 4. Zero the bore sight in accordance with its operation manual. 5. Set the target at the distance, required for th is weapon and this target. 6. Activate LAM in ILP mode. 7. Set minimal divergence of the illuminato r channel. 8. Set ...

  • Newcon Optik LAM 3 IR - page 18

    14 4. Set the minimal divergence of the illuminator channel. 5. Superpose ce nters of the sp ots produced by the aimer and illuminator on the aiming mark by rotating adjustment knobs (1, Fig. 1), (1 7, Fig. 2). 6. Fire the we apon. 7. If point of impact is off the aiming m ark adjust windage and el evation by r otating adjustm ent knobs (1, Fig. 1) ...

  • Newcon Optik LAM 3 IR - page 19

    15 Preparing LAM for transpo rtation 1. Turn LAM off by turning operating modes switch (13, Fig. 2) to OFF position. 2. Disconnect the remote switch from the weapon. 3. Loosen quick release lever (9, Fi g.1), remove LAM from Picat inny rail. 4. Pack LAM and remote switch into the case ...

  • Newcon Optik LAM 3 IR - page 20

    16 5. CARE, STORAGE AND TRANSPORTA TION General LAM is a sophisticated precise optical in strument equipped with electronics. Ther efore, it should be handled with due care. - Never disassem ble LAM. - Keep away from direct sunlight, im pacts, dust, moisture, and sharp cha nges of temperature. - Do not store LAM at tem peratures higher than 70 o C ...

  • Newcon Optik LAM 3 IR - page 21

    17 If LAM was exposed to salt water it should be rinsed in fresh water a nd dried outside at n o more than 55 o C. Long-term storage When preparing for long-term storage, cover the exte rnal metal surfaces of LAM with pr otective lubricant. Eac h 4 (four) years old layer of lubri cant should be removed a nd new layer be applied. To remove ol d laye ...

  • Newcon Optik LAM 3 IR - page 22

    18 2. When preparin g for a long- term storage LA M just received from manufacture r or from workshop ensure that actual set is the same as indicated in the Delivery Set section of this manual. 3. Cases with units shoul d be placed on stands, shelves or in cupboards in dry heated and v entilated premises in accordance with Stora ge conditions as de ...

  • Newcon Optik LAM 3 IR - page 23

    19 8. Presence of acid and alkaline vapor, as well as of other aggressi ve admixtures i n the air i n the storage area may cause damage to L AM. 9. After 4 years of storage, it is necessary to perform thorough inspection of units’ functionality. Transporta tion When packed, LAMs ca n be transported by any covered means in accordance with Storage ...

  • Newcon Optik LAM 3 IR - page 24

    20 6. TROUBLESHOOTING The LED indicator is off when switch is ON. Turn the switch on again. If LAM still does not go ON check that battery is installe d properly and has sufficient charge. Replace battery if necessary. Spot shape or size has chan ged Emitter objective lens is dirty. Flush emitter lens with fresh water and wipe it with soft cloth. I ...

  • Newcon Optik LAM 3 IR - page 25

    21 7. WARRANTY NEWCON warrants this product against defects in material and workmanship for one year from the date o f the original purchase. Longe r warranty is available, subject to the terms of the specific sales contract. Should your Newcon pr oduct prove to be defecti ve during this period, please deliver the produc t securely packaged in its ...

  • Newcon Optik LAM 3 IR - page 26

    22 Postage, insura nce, and ship ping costs i ncurred whi le presenting your NEWCON p roduct for w arranty service are your responsibility. If shipping from North America please incl ude a cheque or money or der payabl e to NEWCON OPTIK fo r the amount of $15.00 to cover handling a nd retu rn shipping . ...

  • Newcon Optik LAM 3 IR - page 27

    23 8. CUSTOMER SUPPORT Should you experience an y difficulties with your NEWCON OP TIK product , consult t he enclosed m anual. If the problem remains unreso lved, contact our customer support department at ( 416) 663-6963 or toll free at 1- 877-368-6666 . Our oper ating hours ar e 9am-5pm, Monday - Friday, Eastern Standard Time. At no tim e should ...

  • Newcon Optik LAM 3 IR - page 28

    24 10. QUALITY CERTIFICATE LAM 3 IR seri al number_______ ____________ __________ complies wit h all technical specifi cations and has passed the inspection. Date of pr oduction: _____________ ____________ ________ Quality Inspector: _____________ ____________ _________ Quality Assurance Seal ...

  • Newcon Optik LAM 3 IR - page 29

    25 ...

  • Newcon Optik LAM 3 IR - page 30

    26 ...

  • Newcon Optik LAM 3 IR - page 31

    27 ...

  • Newcon Optik LAM 3 IR - page 32

    NEWCON OPTIK  M065-24/A/XII R1.I – 8.11 ...

Manufacturer Newcon Optik Category Binoculars

Documents that we receive from a manufacturer of a Newcon Optik LAM 3 IR can be divided into several groups. They are, among others:
- Newcon Optik technical drawings
- LAM 3 IR manuals
- Newcon Optik product data sheets
- information booklets
- or energy labels Newcon Optik LAM 3 IR
All of them are important, but the most important information from the point of view of use of the device are in the user manual Newcon Optik LAM 3 IR.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Newcon Optik LAM 3 IR, service manual, brief instructions and user manuals Newcon Optik LAM 3 IR. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Newcon Optik LAM 3 IR.

A complete manual for the device Newcon Optik LAM 3 IR, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Newcon Optik LAM 3 IR by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Newcon Optik LAM 3 IR.

A complete Newcon Optik manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Newcon Optik LAM 3 IR - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Newcon Optik LAM 3 IR, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Newcon Optik LAM 3 IR, that we can find in the current document
3. Tips how to use the basic functions of the device Newcon Optik LAM 3 IR - which should help us in our first steps of using Newcon Optik LAM 3 IR
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Newcon Optik LAM 3 IR
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Newcon Optik LAM 3 IR in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Newcon Optik LAM 3 IR?

Use the form below

If you did not solve your problem by using a manual Newcon Optik LAM 3 IR, ask a question using the form below. If a user had a similar problem with Newcon Optik LAM 3 IR it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)