    TECHNICAL GUIDE SPLIT -SYSTEM A IR CONDITIONERS 13 SEER – R-410A MODELS: TCGD18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) Due to continuous produc t impr ovement, specifications are subject to change without notice. V isit us on th e web at www .york.com A dditional rating informa tion can be fo und at w ww .ahridirectory . org LISTED ISO 9001 C ...

  • York TCGD18 THRU 60 - page 2

    359315-YTG-B-0408 2 Johnson Controls Unitary Products All dimensions are in inches. They are subject to cha nge without notice. Ce rtif ied dimensio ns will be provide d upon request. Physical and Electrical Dat a MODEL TCGD18 S41S1(H) TCGD24 S41S1(H) TCGD30 S41S1(H) TCGD36 S41S1(H) TCGD42 S41S1(H) TCGD48 S41S1(H) TCGD60 S41S1 Unit Supply V oltage ...

  • York TCGD18 THRU 60 - page 3

    359315-YTG-B-0408 Johnson Controls Unitary Produ cts 3 Additional R-410A Ch arge / Orifice Size for V arious Matched Systems Outdoor Unit TCGD18 S41S1(H) TCGD24 S41S1(H) TCGD30 S41S1(H) TCGD36 S41S1(H) TCGD42 S41S1(H) TCGD48 S41S1(H) TCGD60 S41S1 Required Orifice or TXV 1,2 0.048 / 902 0.055 / 902 0.061 / 907 0.065 / 9 03 0.075 / 903 0.073 / 904 0. ...

  • York TCGD18 THRU 60 - page 4

    359315-YTG-B-0408 4 Johnson Controls Unitary Products PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refr igerant for th e condenser , the smallest evaporator and 15 feet of inter- connecting line tubing. 2. V erify the TXV or orifice and additional charge required for s pecific evaporator coil in t he system using the abo ...

  • York TCGD18 THRU 60 - page 5

    359315-YTG-B-0408 Johnson Controls Unitary Produ cts 5 COOLING CAP ACITY - Wi th Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL W RA TED CFM NET MBH SEER EER TOT A L SENS. 13 SEER AC WITH MA TCGD18S41S1(H) MA08B 17 FC/MC18B 600 17.5 12.9 13.00 1 1.00 TCGD24S41S1(H) MA08B 17 FC/MC36B 800 24.0 16.7 13 .00 1 1.00 MA08B 17 FC/MC35B ...

  • York TCGD18 THRU 60 - page 6

    359315-YTG-B-0408 6 Johnson Controls Unitary Products — = Not applicable. 13 SEER AC WITH AHP / SHP / F*FP TCGD18S41S1(H) AHP18 17 – 650 17.5 12.9 13.00 1 1.00 F4FP024 18 – 600 17.5 12.9 13.00 1 1.00 TCGD24S41S1(H) AHP30 17 – 795 24.0 16.8 13.00 1 1.00 F4FP036 21.5 – 800 24.0 16.7 13.00 1 1.00 TCGD30S41S1(H) AHP30 17 – 1015 29.0 21.0 13 ...

  • York TCGD18 THRU 60 - page 7

    359315-YTG-B-0408 Johnson Controls Unitary Produ cts 7 COOLING CAP ACITY - Up flow , Downflow & Horizont al Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (Min.-max.) W RA TED CFM NET MBH SEER 1 EER TOT A L SENS. TCGD18S41S1(H) 450 - 750 14,17 FC/MC/PC18 600 17.5 12.9 13.00 1 1.00 450 - 750 14 HC18 600 17.5 12.9 13.00 1 1. ...

  • York TCGD18 THRU 60 - page 8

    359315-YTG-B-0408 8 Johnson Controls Unitary Products COOLING CAP ACITY - With V ariable Spe ed Furnaces UNIT MODEL V ARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RA TED CFM Net MBH SEER EER TOT A L SENS. 13 SEER AC WITH V ARIABLE SPEED FUR NACES 2 TCGD18S41S1(H) PV8*A12 FC/MC/PC1 8A 14 600 17.5 13.4 14.00 12.50 PV9*A12 FC/MC/PC1 8A 14 625 17 ...

  • York TCGD18 THRU 60 - page 9

    359315-YTG-B-0408 Johnson Controls Unitary Produ cts 9 TCGD36S41S1(H) PV8*C20 FC/MC/PC48C 21 1200 35.0 25.2 13.50 12.00 P(C,V)9*C16 FC/MC/PC48C 21 1 175 35.0 25.4 14 .00 12.00 P(C,V)9*C20 FC/MC/PC48C 21 1 195 35.0 25.2 14 .00 12.00 P(C,V)9*D20 FC/MC/PC48D 24 1220 35.0 25.4 14 .00 12.00 PV8*C16 HC42 21 1200 36.0 25.4 14.00 12.00 PV8*C20 HC42 21 1200 ...

  • York TCGD18 THRU 60 - page 10

    359315-YTG-B-0408 10 Johnson Controls Unitary Products ACCESSORIES Refer to Price Manual for specific model numbers. HARD ST ART KIT - Required when using TXV i ndoor coil. Also, provides increased starting torque for a reas with low voltage. OFF CYCLE TIMER DELA Y - Provides a 5-minute off cycle to prevent rapid recycling of the compressor . ROOM ...

  • York TCGD18 THRU 60 - page 11

    359315-YTG-B-0408 Johnson Controls Unitary Produ cts 11 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between 73-87 F), sensible cap acity incr eases by 1060 BTUH per 1000 CFM per degr ee above the listed temperature and decreases by 1060 BTUH per 1 000 CFM p ...

  • York TCGD18 THRU 60 - page 12

    359315-YTG-B-0408 12 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those liste d (bet ween 73-87 F), sensible capacit y incr eases by 1060 BTUH per 1000 CFM per deg ree abo ve the listed temperatu re and decre ases by 1060 BTUH per 1000 CFM ...

  • York TCGD18 THRU 60 - page 13

    359315-YTG-B-0408 Johnson Controls Unitary Produ cts 13 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between 73-87 F), sensible cap acity incr eases by 1060 BTUH per 1000 CFM per degr ee above the listed temperature and decreases by 1060 BTUH per 1 000 CFM p ...

  • York TCGD18 THRU 60 - page 14

    359315-YTG-B-0408 14 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those liste d (bet ween 73-87 F), sensible capacit y incr eases by 1060 BTUH per 1000 CFM per deg ree abo ve the listed temperatu re and decre ases by 1060 BTUH per 1000 CFM ...

  • York TCGD18 THRU 60 - page 15

    359315-YTG-B-0408 Johnson Controls Unitary Produ cts 15 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between 73-87 F), sensible cap acity incr eases by 1060 BTUH per 1000 CFM per degr ee above the listed temperature and decreases by 1060 BTUH per 1 000 CFM p ...

  • York TCGD18 THRU 60 - page 16

    359315-YTG-B-0408 16 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those liste d (bet ween 73-87 F), sensible capacit y incr eases by 1060 BTUH per 1000 CFM per deg ree abo ve the listed temperatu re and decre ases by 1060 BTUH per 1000 CFM ...

  • York TCGD18 THRU 60 - page 17

    359315-YTG-B-0408 Johnson Controls Unitary Produ cts 17 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between 73-87 F), sensible cap acity incr eases by 1060 BTUH per 1000 CFM per degr ee above the listed temperature and decreases by 1060 BTUH per 1 000 CFM p ...

  • York TCGD18 THRU 60 - page 18

    Subject to change without notice. Printe d in U.S.A. 359315-YTG-B-0408 Copyright © 2008 by Johnson Controls, Inc. All ri ghts reserved. Supersedes: 359315-YTG-A-0208 Johnson Controls Unitary Product s 5005 Y ork Drive Norman, OK 73069 NOTES ...

Produzent York Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts York TCGD18 THRU 60 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen York
- Bedienungsanleitungen TCGD18 THRU 60
- Produktkarten York
- Informationsbroschüren
- oder Energieetiketten York TCGD18 THRU 60
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung York TCGD18 THRU 60.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen York TCGD18 THRU 60, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen York TCGD18 THRU 60. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts York TCGD18 THRU 60 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts York TCGD18 THRU 60, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von York TCGD18 THRU 60 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von York TCGD18 THRU 60 verständlich ist.

Eine gänzliche Bedienungsanleitung von York sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von York TCGD18 THRU 60 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von York TCGD18 THRU 60 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich York TCGD18 THRU 60, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts York TCGD18 THRU 60 - die uns die ersten Schritte während der Nutzung von York TCGD18 THRU 60 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit York TCGD18 THRU 60 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von York TCGD18 THRU 60 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich York TCGD18 THRU 60?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit York TCGD18 THRU 60 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit York TCGD18 THRU 60 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)