Bedienungsanleitung Graco Hydra-Clean 247549

24 Seiten 1.37 mb
Download

Zur Seite of 24

Summary
  • Graco Hydra-Clean 247549 - page 1

    Instr uctions - P ar ts Hydra-Clean ® Pa c k a g e s 312585E ENG P ac kage solutions for pressure washing applica tions. For use only with water and c leaning solutions. See page 3 f or model inf ormation, including maximum working pressure . Important Safety Instru ctions Read all warnings and instr uct ions in this manual and in your respectiv e ...

  • Graco Hydra-Clean 247549 - page 2

    2 312585E Contents Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Related M anuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 W arnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 W all Mount Pac kages ...

  • Graco Hydra-Clean 247549 - page 3

    Models 312585E 3 Models Chec k your pac kage’ s identification plate (I D) for the 6-digit part number of y our pac kage. T o order repl ace- ment par ts, see Pa r ts star ting on page 14. Related Manuals All pac kages include integr ated air controls , hose and gun, and g round wire. ID TI11530A Par t N o. Maximum W orking Pressure psi (MP a, ba ...

  • Graco Hydra-Clean 247549 - page 4

    Warnings 4 312585E Wa r n i n g s The f ollowing w ar nings are f or the setup , use , grounding, mainten ance, and repair of this equipme nt. The e xclama- tion point symbol alerts you to a gener al warning and the hazard symbol refer s to procedure-specific risk. Ref er bac k to these wa r nings. Add itional, product- specific w arnings may be f ...

  • Graco Hydra-Clean 247549 - page 5

    Warnings 312585E 5 MO VING P ARTS HAZARD Movin g par ts can pinch or amputate fingers and other body parts. • K eep clear of mo ving par ts. • Do not op erate equipme nt with prot ective guards or covers remov ed. • Pressurized equipmen t can star t without warning. Bef ore chec king, moving, o r ser vicing equipment, f ollow the Pressure Re ...

  • Graco Hydra-Clean 247549 - page 6

    Installation 6 312585E Installation The Graco warr anty will not apply if cleaning solutions other than those r ecommended by Graco are used in these units . Only use solutions that are not harmful to the wetted par ts . See the T echnical Data in the displace- ment pump man uals 311825, 311827, an d 312745. See F IG . 1. Connect the suctio n hose ...

  • Graco Hydra-Clean 247549 - page 7

    Installation 312585E 7 A Displacement Pump B Air Motor C Integrated Air Control Module (includes items D-H) D Bleed-type Master Air V alv e (required) E Pump Air Regulator F Air Pressure Gaug e G Saf ety Relief V alv e H Air Filter (hidden) JA i r I n l e t K Air Supply Li ne L Air Line Shut off V alve M Air Line Filter NP o r t a b l e C a r t P F ...

  • Graco Hydra-Clean 247549 - page 8

    Installation 8 312585E Gr ounding Although w ater generally pro vides a natural electrical ground, the f ollowing equip ment must be g rounded if the cleaning chemicals are v olatile . The equipment m ust be grounded. Grounding reduces the risk of static and electric shock b y providing an escape wire f or the electrical current due to static build ...

  • Graco Hydra-Clean 247549 - page 9

    Operation 312585E 9 Operation Pressure Relief Pr ocedure 1. Engage t he trigg er lock. 2. Close the b leed-type master air v alv e to shutoff the pump. 3. Disengage the trigger loc k. 4. Hold a metal par t of the gun firmly to a grounded metal pail. T r igger the gun to reliev e pressure. 5. Engage t he trigg er lock. 6. Open all fluid dr ain valv ...

  • Graco Hydra-Clean 247549 - page 10

    Operation 10 312585E Star ting the Pump 1. Open the b leed-type master ai r valv e (A). 2. T r igger the gun into a grounded met al pail, holding a metal par t of the gun fir mly to the pail. 3. Slowly open the air regulator (E) until the pump star ts running. 4. Run the pump slowly until all the air is purged, release the gun trigger , and lock th ...

  • Graco Hydra-Clean 247549 - page 11

    Operation 312585E 11 ...

  • Graco Hydra-Clean 247549 - page 12

    Troubleshooting 12 312585E T r oubleshooting 1. Relie ve the pressure, page 9. 2. Chec k all possible cause s and problems be fore dis- assemblin g the pump . * T o determine if the fluid hose or gun is obstructed, relie v e the pressure, pa ge 9. Disconnect the fluid ho se and place a container at the pump fluid outlet t o catch any fluid. T ur n ...

  • Graco Hydra-Clean 247549 - page 13

    Repair 312585E 13 Repair Disconnect the Displacement Pump See the Pa r t s dra wings on pages 14 -17. 1. Flush the pump , if possib le. Sto p the pump at the bottom of its stro ke . Relie ve the pr essure, page 9. 2. Disconnect the air , fluid, and suction hoses . 3. Unscrew the coupling nut (14) fro m the connecting rod adapter ( 11). Remov e the ...

  • Graco Hydra-Clean 247549 - page 14

    Parts 14 312585E Pa r t s 247549 Car t Mount P ac ka g e See par ts listing on page 18. TI11268A 1 2 3 4 5 6 7 8 Ref. 20 41 23 15 14 13 16 21 11 22 19 17 18 9 10 12 20 24 25 26 27 28 29 30 37 38 39 40 1a 1b 1d 1c ...

  • Graco Hydra-Clean 247549 - page 15

    Parts 312585E 15 247550 W all Mount P acka ge See par ts listing on page 18. TI11270A 4 32 15 14 13 16 11 19 17 18 9 10 12 20 6 7 8 Ref. 20 23 21 22 24 25 26 30 37 31 ...

  • Graco Hydra-Clean 247549 - page 16

    Parts 16 312585E 247551, 247553, and 258664 Car t Mount P ac kages See par ts listing on page 18. TI11272A 1 2 3 4 5 6 7 8 Ref. 20 41 23 14 13 21 11 22 19 18 9 10 20 24 25 26 27 28 29 30 37 38 39 40 33 15 17 12 34 16 1a 1b 1d 1c ...

  • Graco Hydra-Clean 247549 - page 17

    Parts 312585E 17 247552, 247554, and 258665 W all Mount P ac kages See par ts listing on page 18. TI11274A 4 32 33 14 13 15 11 19 17 18 9 10 12 20 6 7 8 Ref. 20 23 21 22 24 25 26 30 37 31 34 16 ...

  • Graco Hydra-Clean 247549 - page 18

    Parts 18 312585E P ar ts Listings Common P ar ts The f ollowing parts are used on all packages in this man ual. P ar ts that V ar y b y Pac kage Ref. P art Description Qty . 4 1 00133 W ASHER, loc k; 3/8 4 7 NXT021 CONTROL, air , integrated; with non-loc king air regulator; see 311239 1 8 244524 WIRE, g round 1 12 101712 NU T , lock; 5/8-11 3 16 10 ...

  • Graco Hydra-Clean 247549 - page 19

    Kits 312585E 19 Kits Bare Gun Replacement Kits • 15T283, Brass Spr ay Gun (standard) • 15T282, Stainless St eel Spra y Gun (optional) Gun Stainless Steel Fitting Kit • 247880, inclu des stainless steel gun inlet and o utlet fittings Gun W and Repl acement Kits • 15T279, 32 in. (8 13 mm) Stainless Steel W and (standard) • 15T280, 10 in. (2 ...

  • Graco Hydra-Clean 247549 - page 20

    Wall Mounting Bracket Diagram 20 312585E W all Mounting Brac ket Diagram TI8614B 9.0 in. (228.6 mm) 1.6 in. (41.4 mm) 12.4 in. (314.3 mm) 1.0 in. (25.4 mm) 5.3 in. (133.4 mm) 14.5 in. (368.3 mm) 17.8 in. (450.9 mm) 2.0 in. (50.8 mm) 5.4 in. (136.5 mm) 7/16 in. (1 1 mm) diameter h oles for mounting to wa ll 1/2 in. (12.7 mm ) diameter holes for moun ...

  • Graco Hydra-Clean 247549 - page 21

    Dimensions 312585E 21 Dimensions A TI11379A Cart Mount Pac kages (247549, 24755 1, 247553) W all Mount P ackages (247550, 2 47552, 247554) TI11378A A D C B1 D C B2 Packag e A in. (mm) B1 in. (mm) B2 in. (mm) C in. (mm) D in. (mm) Air Inlet (in.) Pump Fluid Inlet (in.) Pump Fluid Outlet (in.) We i g ht lb (kg) 247549 50.0 (1270) 5.6 (142) 17.1 (434) ...

  • Graco Hydra-Clean 247549 - page 22

    Technica l Data 22 312585E T echnical Data Pump P erformance Charts 12:1 Ratio Pum ps (247549, 247550) Maximum fluid wor king pressure P ar t N os. 247549 and 247550 . . . . . . . . . . . . . . . . . . 1250 psi (8 .6 MP a, 86.2 bar) P ar t N os. 247551 and 247552 . . . . . . . . . . . . . . . . . . 2275 psi (15.7 MPa, 156.9 bar) P ar t N os. 247553 ...

  • Graco Hydra-Clean 247549 - page 23

    Pump Performance Charts 312585E 23 23:1 Ratio Pum ps (247551, 247552) 30:1 Ratio Pum ps (247553, 247554) 45:1 Ratio Pum ps (258664, 258665) Spray Tip Orifice Size, in. (mm) 40 psi (0.3 MPa, 3 bar) Air Supply 70 psi (0.5 MP a, 5 bar) Air Supply 100 psi (0.7 MPa, 7 bar) Air Supply gpm (l/min) cfm (m 3 /min) Wo r k i n g Pressure in psi (MPa, bar) gp ...

  • Graco Hydra-Clean 247549 - page 24

    All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. This manual contains English. MM 312585 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. P.O. BOX 14 ...

Produzent Graco Kategorie Pressure Washer

Dokumente, die wir vom Produzenten des Geräts Graco Hydra-Clean 247549 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Graco
- Bedienungsanleitungen Hydra-Clean 247549
- Produktkarten Graco
- Informationsbroschüren
- oder Energieetiketten Graco Hydra-Clean 247549
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Graco Hydra-Clean 247549.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Graco Hydra-Clean 247549, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Graco Hydra-Clean 247549. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Graco Hydra-Clean 247549 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Graco Hydra-Clean 247549, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Graco Hydra-Clean 247549 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Graco Hydra-Clean 247549 verständlich ist.

Eine gänzliche Bedienungsanleitung von Graco sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Graco Hydra-Clean 247549 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Graco Hydra-Clean 247549 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Graco Hydra-Clean 247549, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Graco Hydra-Clean 247549 - die uns die ersten Schritte während der Nutzung von Graco Hydra-Clean 247549 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Graco Hydra-Clean 247549 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Graco Hydra-Clean 247549 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Graco Hydra-Clean 247549?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Graco Hydra-Clean 247549 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Graco Hydra-Clean 247549 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)