    1 372 ROUTE 4 BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com SEA FROST BD 12 OR 24 VOLT D.C. SYSTEM With Water Cooling Option CONDENSING UNIT LOCATION AND MOUNTING The water-cooling option should be consider ed supplemental cooling. Installation should proceed with a proper a ...

  • Sea Frost 372 ROUTE - page 2

    2 Service access and installation requires that the front, left end (inlet) and back (condenser) air outlet be exposed. A duct hose will require 4 inches of clearance past the end of the cabinet. Mount the Sea Frost BD level, (the compressor is at the bottom). The BD may be platform mounted. Two holes have been drill ed through the bottom for screw ...

  • Sea Frost 372 ROUTE - page 3

    3 PUMP WIRING Connect the red pump wire to the terminal screw marked pump (+) and the black one to (-) under the compressor housing cover. Be sure the toggle switch is off until the boat is launched and the pump is wet. MOUNTING THE EVAPORATOR PLATE The plate should be mounted in the cabinet as high as possible to take advantage of thermal convecti ...

  • Sea Frost 372 ROUTE - page 4

    4 KINKING THE TUBES. ALL BENDS SH OULD BE SMOOTH WITH NO LESS THAN A 2" RADIUS. Support the tubing every 18 inches as necessary using tie wraps fastened with self- tapping screws. Insulate at least 3' of the line set as it exit s the refrigerator box. Seal both sides of the exit holes in the refrigerator box with permagum sealing compound ...

  • Sea Frost 372 ROUTE - page 5

    5 WIRE SIZE 12-volt installations use AWG #10 wire for dist ances up to 10 feet for the wire pair, and #8 AWG wire for distances up to 25 feet for the wire pair. Fuse 15 Amps. 24 Volts: The module will self calibrate to the applied voltage and provide proper fan voltage. The remote water pump must be a 24volt pump. Fuse 7.5 Amps. If the polarity is ...

  • Sea Frost 372 ROUTE - page 6

    6 STANDARD THERMOSTAT WIRING CONNECTIONS Connect the thermostat wires to the ye llow wire harness, which is connected to terminals C and T on the module. The yellow wire harness contains a 1500-ohm resistor, which programs the module to oper ate the compressor at maximum RPM. There is no polarity requirement. STANDARD THERMOSTAT OPERATION The therm ...

  • Sea Frost 372 ROUTE - page 7

    7 OPTIONAL REMOTE THERMOSTAT OPERATION Attach the sensing bulb with the bulb clip to one of the lower mounting screws on the plate. The sensing bulb must be in excellent thermal contact with the plate. We re commend that the probe be mounted on the plate in one of the lower mounting positions as shown in the drawing below. This is best because thes ...

  • Sea Frost 372 ROUTE - page 8

    8 To lower box temperature, rotate this screw counter clockwise. One full revolution will change the box temperature approx imately 6 degrees F. To raise the temperature in the box rotate the screw clockwise. Make small adjustments. Record all adjustments. OPERATION DESCRIPTION Once installed the BD is started by turn ing the thermostat clockwise f ...

  • Sea Frost 372 ROUTE - page 9

    9 DEFROSTING Excessive frost/ice build up on the plate will reduce the cooling effect by insulating the evaporator plate. Allowing t he evaporator plate to warm above freezing is one method of defrosting. Boiling water or a scraper will also work. OPERATION INSPECTION Within a few minutes of starting the Sea Frost BD, the tubing in close proximity ...

  • Sea Frost 372 ROUTE - page 10

    10 TROUBLESHOOTING A light emitting diode (LED) is connected between terminals + and D. In case the electronic unit records an operational error, the diode will flash a number of times. The number of flashes depends on what kind of operational error was recorded. Each flash lasts 1/4 second. After the actual num ber of flashes there will be a delay ...

  • Sea Frost 372 ROUTE - page 11

    11 ...

  • Sea Frost 372 ROUTE - page 12

    12 AVAILABLE OPTIONS Remote Thermostat Panel Kit Speed Control Panel Kit Speed Control with Remote Thermostat Combination Panel Kit Electronic Thermostat Thermometer Panel Kit Remote Dial Thermometer 4" Vent Hose 4" Vent Grill Ice Tray Kit Bulkhead Mounting Brackets Bin Lid for Freezer Bin Water Cooling Option Water Pump ...

  • Sea Frost 372 ROUTE - page 13

    13 Our Repair Policy Your Sea Frost BD system is manufactured to t he highest standards and thoroughly tested. If you experience problems with your system requiring technical service, return it to us freight prepaid. When a system is returned to us we will fix manufacturing defects and failures occurring in normal operation for one year from the da ...

Fabricante Sea Frost Categoría Refrigerator

Los documentos del dispositivo Sea Frost 372 ROUTE que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Sea Frost
- manuales de instrucciones 372 ROUTE
- hojas de producto Sea Frost
- folletos informativos
- o etiquetas energéticas Sea Frost 372 ROUTE
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Sea Frost 372 ROUTE.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Sea Frost 372 ROUTE, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Sea Frost 372 ROUTE. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Sea Frost 372 ROUTE.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Sea Frost 372 ROUTE, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Sea Frost 372 ROUTE. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Sea Frost 372 ROUTE.

El manual de instrucciones completo de Sea Frost debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Sea Frost 372 ROUTE - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Sea Frost 372 ROUTE, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Sea Frost 372 ROUTE que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Sea Frost 372 ROUTE - que deben facilitarnos los primeros pasos durante el uso de Sea Frost 372 ROUTE
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Sea Frost 372 ROUTE
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Sea Frost 372 ROUTE en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Sea Frost 372 ROUTE?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Sea Frost 372 ROUTE, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Sea Frost 372 ROUTE probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)