    1 372 ROUTE 4 BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com SEA FROST BD 12 OR 24 VOLT D.C. SYSTEM With Water Cooling Option CONDENSING UNIT LOCATION AND MOUNTING The water-cooling option should be consider ed supplemental cooling. Installation should proceed with a proper a ...

  • Sea Frost 372 ROUTE - page 2

    2 Service access and installation requires that the front, left end (inlet) and back (condenser) air outlet be exposed. A duct hose will require 4 inches of clearance past the end of the cabinet. Mount the Sea Frost BD level, (the compressor is at the bottom). The BD may be platform mounted. Two holes have been drill ed through the bottom for screw ...

  • Sea Frost 372 ROUTE - page 3

    3 PUMP WIRING Connect the red pump wire to the terminal screw marked pump (+) and the black one to (-) under the compressor housing cover. Be sure the toggle switch is off until the boat is launched and the pump is wet. MOUNTING THE EVAPORATOR PLATE The plate should be mounted in the cabinet as high as possible to take advantage of thermal convecti ...

  • Sea Frost 372 ROUTE - page 4

    4 KINKING THE TUBES. ALL BENDS SH OULD BE SMOOTH WITH NO LESS THAN A 2" RADIUS. Support the tubing every 18 inches as necessary using tie wraps fastened with self- tapping screws. Insulate at least 3' of the line set as it exit s the refrigerator box. Seal both sides of the exit holes in the refrigerator box with permagum sealing compound ...

  • Sea Frost 372 ROUTE - page 5

    5 WIRE SIZE 12-volt installations use AWG #10 wire for dist ances up to 10 feet for the wire pair, and #8 AWG wire for distances up to 25 feet for the wire pair. Fuse 15 Amps. 24 Volts: The module will self calibrate to the applied voltage and provide proper fan voltage. The remote water pump must be a 24volt pump. Fuse 7.5 Amps. If the polarity is ...

  • Sea Frost 372 ROUTE - page 6

    6 STANDARD THERMOSTAT WIRING CONNECTIONS Connect the thermostat wires to the ye llow wire harness, which is connected to terminals C and T on the module. The yellow wire harness contains a 1500-ohm resistor, which programs the module to oper ate the compressor at maximum RPM. There is no polarity requirement. STANDARD THERMOSTAT OPERATION The therm ...

  • Sea Frost 372 ROUTE - page 7

    7 OPTIONAL REMOTE THERMOSTAT OPERATION Attach the sensing bulb with the bulb clip to one of the lower mounting screws on the plate. The sensing bulb must be in excellent thermal contact with the plate. We re commend that the probe be mounted on the plate in one of the lower mounting positions as shown in the drawing below. This is best because thes ...

  • Sea Frost 372 ROUTE - page 8

    8 To lower box temperature, rotate this screw counter clockwise. One full revolution will change the box temperature approx imately 6 degrees F. To raise the temperature in the box rotate the screw clockwise. Make small adjustments. Record all adjustments. OPERATION DESCRIPTION Once installed the BD is started by turn ing the thermostat clockwise f ...

  • Sea Frost 372 ROUTE - page 9

    9 DEFROSTING Excessive frost/ice build up on the plate will reduce the cooling effect by insulating the evaporator plate. Allowing t he evaporator plate to warm above freezing is one method of defrosting. Boiling water or a scraper will also work. OPERATION INSPECTION Within a few minutes of starting the Sea Frost BD, the tubing in close proximity ...

  • Sea Frost 372 ROUTE - page 10

    10 TROUBLESHOOTING A light emitting diode (LED) is connected between terminals + and D. In case the electronic unit records an operational error, the diode will flash a number of times. The number of flashes depends on what kind of operational error was recorded. Each flash lasts 1/4 second. After the actual num ber of flashes there will be a delay ...

  • Sea Frost 372 ROUTE - page 11

    11 ...

  • Sea Frost 372 ROUTE - page 12

    12 AVAILABLE OPTIONS Remote Thermostat Panel Kit Speed Control Panel Kit Speed Control with Remote Thermostat Combination Panel Kit Electronic Thermostat Thermometer Panel Kit Remote Dial Thermometer 4" Vent Hose 4" Vent Grill Ice Tray Kit Bulkhead Mounting Brackets Bin Lid for Freezer Bin Water Cooling Option Water Pump ...

  • Sea Frost 372 ROUTE - page 13

    13 Our Repair Policy Your Sea Frost BD system is manufactured to t he highest standards and thoroughly tested. If you experience problems with your system requiring technical service, return it to us freight prepaid. When a system is returned to us we will fix manufacturing defects and failures occurring in normal operation for one year from the da ...

Производитель Sea Frost Категория Refrigerator

Документы, которые мы получаем от производителя устройства Sea Frost 372 ROUTE мы можем разделить на несколько групп. Это в частности:
- технические чертежи Sea Frost
- инструкции обслуживания 372 ROUTE
- паспорта изделия Sea Frost
- информационные брошюры
- энергетические этикетки Sea Frost 372 ROUTE
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Sea Frost 372 ROUTE.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Sea Frost 372 ROUTE, инструкции обслуживания, короткие инструкции или инструкции пользователя Sea Frost 372 ROUTE. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Sea Frost 372 ROUTE.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Sea Frost 372 ROUTE, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Sea Frost 372 ROUTE пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Sea Frost 372 ROUTE.

Полная инструкция обслуживания Sea Frost, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Sea Frost 372 ROUTE - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Sea Frost 372 ROUTE, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Sea Frost 372 ROUTE, которое найдем в данном документе
3. Советы по использованию основных функций устройства Sea Frost 372 ROUTE - которые должны облегчить нам первые шаги во время использования Sea Frost 372 ROUTE
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Sea Frost 372 ROUTE
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Sea Frost 372 ROUTE в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Sea Frost 372 ROUTE?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Sea Frost 372 ROUTE, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Sea Frost 372 ROUTE со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)