    www .edelbrock.com Page 1 of 17 Please study these instructions carefully before installing your new Progressive Nitrous Contoller . If you have any questions, please contact our T echnical Hotline at : 1-800-416-8628 from 7 am - 5pm, Monday-Friday , Pacific Standard Time or e-mail us at Edelbrock@Edelbrock.com . Important Information - Y ou must u ...

  • Edelbrock 71900 - page 2

    www .edelbrock.com Page 2 of 17 71900 - Progressive Nitrous Controller The 71900 Progressive Nitrous Controller was designed using the latest digital technology a vailable. The result is a controller which is extremely accurate and user -friendly . A simple and functional programming interface allows the user to set important nitrous parameters in ...

  • Edelbrock 71900 - page 3

    www .edelbrock.com Page 3 of 17 Nitrous Delay T imer: A digital timer is provided that can be used to delay the start of the nitrous. This timer begins counting down when the activation terminal is on (+12v a pplied). If the activation signal is removed, the delay timer will halt until the signal is re-applied. The delay timer can be programmed fro ...

  • Edelbrock 71900 - page 4

    www .edelbrock.com Page 4 of 17 T ABLE OF CONTENTS Page # Programming +12 V olt Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Nitrous Delay T imer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 ...

  • Edelbrock 71900 - page 5

    www .edelbrock.com Page 5 of 17 Programming the +12 Volt Timer Press and release the FUNCTION switch until the message “+12V T imer Delay” a ppears on the display . After the function message has scrolled across the display , the current +12 Volt Timer setting will appear on the display . T o adjust the +12 volt timer value, press the desired d ...

  • Edelbrock 71900 - page 6

    www .edelbrock.com Page 6 of 17 Programming the Nitrous Starting Percentage Press and release the FUNCTION s witch until the message “Starting Percentage” appears on the display . After the function message has scrolled across the display , the current nitrous starting percentage setting will appear on the display . T o adjust the nitrous start ...

  • Edelbrock 71900 - page 7

    www .edelbrock.com Page 7 of 17 Programming the Nitrous Power Ramp Time NOTE - If the dual ramp feature is enabled fron the options menu, there will be a “Nitrous Build Time #2” in the menu list. The programming method is the same as the “Build Time #1”. Please refer to the section “Options Menu” and “Using the Dual Ramp Feature” fo ...

  • Edelbrock 71900 - page 8

    www .edelbrock.com Page 8 of 17 Viewing Run Data and Entering the Options Menu Press and release the FUNCTION switch until the message “Edelbrock Nitrous Systems - 71900” appears on the display . Press and hold the ENTER s witch, the display will show the time at which the activation input was turned OFF for the previous progressive cyc le. Aft ...

  • Edelbrock 71900 - page 9

    www .edelbrock.com Page 9 of 17 Setting the Dual Nitrous Power Ramp ON/OFF Enter the Options Menu, press and release the FUNCTION s witch until the message “Dual Ramp Nitrous” appears on the display . Press and release the ENTER switch to turn this feature ON or OFF . After pressing the ENTER s witch, the display will show the new state of the ...

  • Edelbrock 71900 - page 10

    www .edelbrock.com Page 10 of 17 Setting +12V Timer Output Hold ON/OFF Enter the Options Menu, press and release the FUNCTION s witch until the message "+12V Timer Output Hold" appears on the display . Press and release the ENTER switch to turn this feature ON or OFF . After pressing the ENTER switch, the display will show the new state o ...

  • Edelbrock 71900 - page 11

    www .edelbrock.com Page 11 of 17 How the Dual Power Ramp Functions The dual nitrous ramp feature enables the user to have more precise control over the nitrous po wer ramp. When the dual ramp feature is enabled, there are two more selections added to the Main Menu. These are "Final Percent #1" and "Nitrous Build Time #2". Using ...

  • Edelbrock 71900 - page 12

    www .edelbrock.com Page 12 of 17 Items Included with the 71900 Controller 1 - Wiring Harness 2 - Installation & User Manual Items Needed that are NOT Supplied with Controller 1 - Nitrous Kit 2 - Safety Solenoid 3 - Activation Switches as needed, if they were not inc luded with the nitrous kit. 4 - RPM Window Switch; required in EFI vehic les th ...

  • Edelbrock 71900 - page 13

    www .edelbrock.com Page 13 of 17 ©2008 Edelbrock Corporation Catalog #71900 Brochure #63-0473 Rev . 08/08 - AJ/mc An optional RPM windo w switch may be connected here. Any RPM switch with a ground control output may be used. NOTE - Most factory fuel injection systems will cut the fuel during an over-rev condition. If the nitrous is NOT controlled ...

  • Edelbrock 71900 - page 14

    Progressive Controller Wiring Diagram with Several Options Page 14 of 17 ©2008 Edelbrock Corporation Catalog #71900 Brochure #63-0473 Rev . 08/08 - AJ/mc Nitrous Arming Switch T rans Brake Button +12 Volt +12 Volt T rans Brake Solenoid Ground Ground Micro Switch 87A 87 30 85 86 87A 87 30 85 86 87A 87 30 85 86 87A 87 30 85 86 MSD 2 Step 1 2 Ground ...

  • Edelbrock 71900 - page 15

    www .edelbrock.com Page 15 of 17 Electrical Specifications Normal Operating Voltage 10.0 to 16.0 Volts, Nega tive Ground Controller will turn OFF at 6.2 Volts +12 Volt Timer Output 1 AMP Maximum, 80mA sink to ground when timer output is OFF . Nitrous Solenoid Ground 45 AMPs Maximum Activation Input .5mA at 12.0 Volts Weight .8 lb. Overall Height 1. ...

  • Edelbrock 71900 - page 16

    www .edelbrock.com Page 16 of 17 ©2008 Edelbrock Corporation Catalog #71900 Brochure #63-0473 Rev . 08/08 - AJ/mc Controller Wiring Controller power and ground wires should be routed directly to the batter y or other isolated po wer source. F or excessive distances, supplied po wer wires should be replaced with heavier gauge wire. T wo red wires a ...

  • Edelbrock 71900 - page 17

    www .edelbrock.com Page 17 of 17 SERVICE In the event that your Progressive Nitrous System should need ser vicing, return the unit freight pre-paid to the Edelbrock Service and Repair facility a t 2700 California Street, T orrance, CA 90503. Do not attempt to disassemble or service the components of the system yourself. Doing so may void the warran ...

Fabricante Edelbrock Categoría Automobile Parts

Los documentos del dispositivo Edelbrock 71900 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Edelbrock
- manuales de instrucciones 71900
- hojas de producto Edelbrock
- folletos informativos
- o etiquetas energéticas Edelbrock 71900
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Edelbrock 71900.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Edelbrock 71900, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Edelbrock 71900. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Edelbrock 71900.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Edelbrock 71900, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Edelbrock 71900. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Edelbrock 71900.

El manual de instrucciones completo de Edelbrock debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Edelbrock 71900 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Edelbrock 71900, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Edelbrock 71900 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Edelbrock 71900 - que deben facilitarnos los primeros pasos durante el uso de Edelbrock 71900
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Edelbrock 71900
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Edelbrock 71900 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Edelbrock 71900?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Edelbrock 71900, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Edelbrock 71900 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)