Manuale per l’uso Edelbrock 71900

17 pagine 0.28 mb
Scarica

Vai alla pagina of 17

Summary
  • Edelbrock 71900 - page 1

    www .edelbrock.com Page 1 of 17 Please study these instructions carefully before installing your new Progressive Nitrous Contoller . If you have any questions, please contact our T echnical Hotline at : 1-800-416-8628 from 7 am - 5pm, Monday-Friday , Pacific Standard Time or e-mail us at Edelbrock@Edelbrock.com . Important Information - Y ou must u ...

  • Edelbrock 71900 - page 2

    www .edelbrock.com Page 2 of 17 71900 - Progressive Nitrous Controller The 71900 Progressive Nitrous Controller was designed using the latest digital technology a vailable. The result is a controller which is extremely accurate and user -friendly . A simple and functional programming interface allows the user to set important nitrous parameters in ...

  • Edelbrock 71900 - page 3

    www .edelbrock.com Page 3 of 17 Nitrous Delay T imer: A digital timer is provided that can be used to delay the start of the nitrous. This timer begins counting down when the activation terminal is on (+12v a pplied). If the activation signal is removed, the delay timer will halt until the signal is re-applied. The delay timer can be programmed fro ...

  • Edelbrock 71900 - page 4

    www .edelbrock.com Page 4 of 17 T ABLE OF CONTENTS Page # Programming +12 V olt Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Nitrous Delay T imer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 ...

  • Edelbrock 71900 - page 5

    www .edelbrock.com Page 5 of 17 Programming the +12 Volt Timer Press and release the FUNCTION switch until the message “+12V T imer Delay” a ppears on the display . After the function message has scrolled across the display , the current +12 Volt Timer setting will appear on the display . T o adjust the +12 volt timer value, press the desired d ...

  • Edelbrock 71900 - page 6

    www .edelbrock.com Page 6 of 17 Programming the Nitrous Starting Percentage Press and release the FUNCTION s witch until the message “Starting Percentage” appears on the display . After the function message has scrolled across the display , the current nitrous starting percentage setting will appear on the display . T o adjust the nitrous start ...

  • Edelbrock 71900 - page 7

    www .edelbrock.com Page 7 of 17 Programming the Nitrous Power Ramp Time NOTE - If the dual ramp feature is enabled fron the options menu, there will be a “Nitrous Build Time #2” in the menu list. The programming method is the same as the “Build Time #1”. Please refer to the section “Options Menu” and “Using the Dual Ramp Feature” fo ...

  • Edelbrock 71900 - page 8

    www .edelbrock.com Page 8 of 17 Viewing Run Data and Entering the Options Menu Press and release the FUNCTION switch until the message “Edelbrock Nitrous Systems - 71900” appears on the display . Press and hold the ENTER s witch, the display will show the time at which the activation input was turned OFF for the previous progressive cyc le. Aft ...

  • Edelbrock 71900 - page 9

    www .edelbrock.com Page 9 of 17 Setting the Dual Nitrous Power Ramp ON/OFF Enter the Options Menu, press and release the FUNCTION s witch until the message “Dual Ramp Nitrous” appears on the display . Press and release the ENTER switch to turn this feature ON or OFF . After pressing the ENTER s witch, the display will show the new state of the ...

  • Edelbrock 71900 - page 10

    www .edelbrock.com Page 10 of 17 Setting +12V Timer Output Hold ON/OFF Enter the Options Menu, press and release the FUNCTION s witch until the message "+12V Timer Output Hold" appears on the display . Press and release the ENTER switch to turn this feature ON or OFF . After pressing the ENTER switch, the display will show the new state o ...

  • Edelbrock 71900 - page 11

    www .edelbrock.com Page 11 of 17 How the Dual Power Ramp Functions The dual nitrous ramp feature enables the user to have more precise control over the nitrous po wer ramp. When the dual ramp feature is enabled, there are two more selections added to the Main Menu. These are "Final Percent #1" and "Nitrous Build Time #2". Using ...

  • Edelbrock 71900 - page 12

    www .edelbrock.com Page 12 of 17 Items Included with the 71900 Controller 1 - Wiring Harness 2 - Installation & User Manual Items Needed that are NOT Supplied with Controller 1 - Nitrous Kit 2 - Safety Solenoid 3 - Activation Switches as needed, if they were not inc luded with the nitrous kit. 4 - RPM Window Switch; required in EFI vehic les th ...

  • Edelbrock 71900 - page 13

    www .edelbrock.com Page 13 of 17 ©2008 Edelbrock Corporation Catalog #71900 Brochure #63-0473 Rev . 08/08 - AJ/mc An optional RPM windo w switch may be connected here. Any RPM switch with a ground control output may be used. NOTE - Most factory fuel injection systems will cut the fuel during an over-rev condition. If the nitrous is NOT controlled ...

  • Edelbrock 71900 - page 14

    Progressive Controller Wiring Diagram with Several Options Page 14 of 17 ©2008 Edelbrock Corporation Catalog #71900 Brochure #63-0473 Rev . 08/08 - AJ/mc Nitrous Arming Switch T rans Brake Button +12 Volt +12 Volt T rans Brake Solenoid Ground Ground Micro Switch 87A 87 30 85 86 87A 87 30 85 86 87A 87 30 85 86 87A 87 30 85 86 MSD 2 Step 1 2 Ground ...

  • Edelbrock 71900 - page 15

    www .edelbrock.com Page 15 of 17 Electrical Specifications Normal Operating Voltage 10.0 to 16.0 Volts, Nega tive Ground Controller will turn OFF at 6.2 Volts +12 Volt Timer Output 1 AMP Maximum, 80mA sink to ground when timer output is OFF . Nitrous Solenoid Ground 45 AMPs Maximum Activation Input .5mA at 12.0 Volts Weight .8 lb. Overall Height 1. ...

  • Edelbrock 71900 - page 16

    www .edelbrock.com Page 16 of 17 ©2008 Edelbrock Corporation Catalog #71900 Brochure #63-0473 Rev . 08/08 - AJ/mc Controller Wiring Controller power and ground wires should be routed directly to the batter y or other isolated po wer source. F or excessive distances, supplied po wer wires should be replaced with heavier gauge wire. T wo red wires a ...

  • Edelbrock 71900 - page 17

    www .edelbrock.com Page 17 of 17 SERVICE In the event that your Progressive Nitrous System should need ser vicing, return the unit freight pre-paid to the Edelbrock Service and Repair facility a t 2700 California Street, T orrance, CA 90503. Do not attempt to disassemble or service the components of the system yourself. Doing so may void the warran ...

Fabbricante Edelbrock Categoria Automobile Parts

I documenti che otteniamo dal fabbricante del dispositivoEdelbrock 71900 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Edelbrock
- manuali per l’uso 71900
- schede prodotto Edelbrock
- opuscoli
- o etichette energetiche Edelbrock 71900
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Edelbrock 71900.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Edelbrock 71900, manuali di manutenzione, brevi manuali o manuali utente Edelbrock 71900. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Edelbrock 71900.

Manuali per l’uso simili

Manuale completo del dispositivo Edelbrock 71900, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Edelbrock 71900 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Edelbrock 71900.

Il manuale per l’uso completo Edelbrock, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Edelbrock 71900 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Edelbrock 71900, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Edelbrock 71900 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Edelbrock 71900 - che ci dovrebbe aiutare nei primi passi durante l'uso Edelbrock 71900
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Edelbrock 71900
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Edelbrock 71900 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Edelbrock 71900?

Utilizza il modulo sottostante

Se non hai risolto il problema con Edelbrock 71900 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Edelbrock 71900 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)