  • Zephyr ESL-M90AS - page 2

    2 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING . INST AL LA TION MUST COMPL Y WITH ALL LOCAL CODES. IMP ORT ANT : Save these Instructions for the Local Electrical Inspector s use. INS T ALLER: Please leave these Instructions with this unit for the owner . OWNER: Please ret ain these instructions for future reference. Safety W arning: T urn ...

  • Zephyr ESL-M90AS - page 3

    3 www .zephyronline.com T able of Content s Import ant safet y Notice ..................................................................... 4 Electrical & Installa tion requir ements ............................................. 5 Electrical requirements .............................................................. 5 Before installing the hood ...

  • Zephyr ESL-M90AS - page 4

    4 Import ant safety Notice CAUTION: FOR GENERAL VENTILA TING USE ONL Y . DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MA TERIALS OR VA P O R S . W ARNING T O REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, O R INJURY T O PERSONS, OBSER VE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer . If you have questions, contact the m ...

  • Zephyr ESL-M90AS - page 5

    5 www .zephyronline.com Electrical & Inst allation requirement s ELECTRICAL REQUIREMENTS Important: Observe all governing codes and ordinances. It is the customers responsibility:  T o co nt act a qualified electrical inst all er .  T o assure that the electrical installation is adequate and in conformance with National Electrical Code ...

  • Zephyr ESL-M90AS - page 6

    6 List of Materials PARTS SUPPLIED:  Blower unit housing  Hood canopy  Met al filter x 1  Halogen light bulb x 2  Duct covers  Remote Control  Duct Cover support bracket (3 pieces to assemble)  Hardware Packet: 4x8 screws x 4 (to assemble Duct cover support bracket) 6x70 screws x 2 (to fix Duct Cover support bracket) 10x60 w ...

  • Zephyr ESL-M90AS - page 7

    7 www .zephyronline.com 1/2" 2"min 8" 7/16* Side Cabinet Side Cabinet 35" 7/16 min. cabinets opening wid ths 24" to 32" bottom of canopy to cooking surface ceiling CenterLine 1 1" 1/2 21" 1/8 11 " 11 " Ducting and conduit area passage(Duct bends are not considered) max 51" 15/16 * min 36" ...

  • Zephyr ESL-M90AS - page 8

    8 Ducting version Non-vented (recirculating) version B B B Pipe Pipe Pipe F-H- G Inst allation Instructions Closely follow the instructions set out in this manual. All responsibility , for any eventu al inc onve nien ces, damage s or fires caused by not comp lyin g with the instru ctio ns in this manual, is declined. VENTING METHODS The hood is equ ...

  • Zephyr ESL-M90AS - page 9

    9 www .zephyronline.com Inst allation - Ductwork Calculation Sheet 3 1/4  x 10 Rect., straight 6  Round,, straight 7", 8 Round,, straight 3 1/4  x 10 Rect.90° elbow 3 1/4  x 10 Rect.45° elbow 3 1/4  x 10 Rect.90° flat elbow 3 1/4  x 10 Rect. wall cap with damper 3 1/4  x 10 Rect.to 6  round trans ...

  • Zephyr ESL-M90AS - page 10

    10 Inst allation Assembling the duct cover support bracket (3 pa r t s ) : The three par t s should be fixed with 4 screws, the support extension is a djustable and should correspond to the internal width of the upper duct cover . = = X Duct cover support bracket X Upper Duct cover 1. If possible, disconnect and move freestan ding or slide-in range ...

  • Zephyr ESL-M90AS - page 11

    11 www .zephyronline.com 10. Determine the required height for the conduit and cut a 1-1/4" (3.2 cm) hole at this location. Run wires through hole according the National Electrical Code or CSA S t andards and local codes and ordinances. There must be enough power supply cable from the fused disconnect (or circuit breaker) box to make the conne ...

  • Zephyr ESL-M90AS - page 12

    12 d. Fasten the hood to the motor unit using 6 screws from the bottom (release the grease filter to access fixing points. 15. Hang hood with the 2 mounting hooks. W ARNING Excessive Weight Hazard - Use two or more people to move and install range hood. Failure to do so can result in back or other injury . 16. Level the appliance, using a carpenter ...

  • Zephyr ESL-M90AS - page 13

    13 www .zephyronline.com 19. Electrical connection W ARNING Electrical Shock Hazard W arning: T urn off power circuit at the service panel before wiring this unit. 120 V AC, 15 or 20 Amp circuit required. ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GR ...

  • Zephyr ESL-M90AS - page 14

    14 Inst allation 22. Install duct cover with 2 screws first on duct cover support bracket, then slide the duct lower section towards the bottom. 23. Fit co ntrol bal l wi th it s m olex plug on its housing and twist in place. a  15 ° OK! b c 24. Perform connection between plates from control ball and from electronic box. 25.Fold all cables and ...

  • Zephyr ESL-M90AS - page 15

    15 www .zephyronline.com Description of the hood 1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp (position and nr . of lamps m ay v ary ) 5 Hood canopy 6 Duct cover 7 Air outlet (used for Ductless version only) 6 7 2 3 4 5 1 ...

  • Zephyr ESL-M90AS - page 16

    16 Description of the hood - Control Ball CONTROLS Use the high suction speed in cases of concentrated kitchen vapours. It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to l eave in operation during cooking and for another 15 minutes approximately after terminating cooking. Description of control ball ...

  • Zephyr ESL-M90AS - page 17

    17 www .zephyronline.com Description of the hood - Remote Control USING THE REMOTE CONTROL This device complies with p art 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause und ...

  • Zephyr ESL-M90AS - page 18

    18 Maintenance Prior to any maintenance operation ensure that the cooker hood is disconnected from the power supply . CLEANING The cooker hood should be cleaned regularly internally and externally . For cleaning use a cloth moistened with a neutral liquid detergents. Avoid abrasive detergents. Warning: Failure to carry out the basic standards of th ...

  • Zephyr ESL-M90AS - page 19

    19 www .zephyronline.com T rouble Shooting Af ter inst allation, the unit doesnt work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the light s are not. The hood is not venting out properly . Met al filter is vibrating. 1. The power source is not turned ON. 2. The power line and the cable locking connec ...

  • Zephyr ESL-M90AS - page 20

    20 W arranty T O O BT AIN SERVICE UNDER W ARRANTY : or any Service Related Questions, please call: 1-888-880-8368 S taple your receipt here. Proof of the original purchase date is needed to obtain ser vic e under the warranty . T O O B T AIN SERVICE UNDER W ARRANTY : Y ou must present proof of original purchase date. Please keep a copy of your date ...

  • Zephyr ESL-M90AS - page 21

    21 www .zephyronline.com List of Part s and Accessories Part Description Part# Part Description Part# Ductless Recirculating Kit charcoal replacement filter duct cover extension kit internal blower - 600 cfm in-line blower - 1 100 cfm EBI-600A EBN-1 1 00 A ZRC-00SA Z0F-C060 Z1C-00SL halogen bulb, 12V 20 W metal filter remote control (RF) remote con ...

  • Zephyr ESL-M90AS - page 22

    22 ...

  • Zephyr ESL-M90AS - page 23

    23 www .zephyronline.com ...

Fabricante Zephyr Categoría Ventilation Hood

Los documentos del dispositivo Zephyr ESL-M90AS que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Zephyr
- manuales de instrucciones ESL-M90AS
- hojas de producto Zephyr
- folletos informativos
- o etiquetas energéticas Zephyr ESL-M90AS
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Zephyr ESL-M90AS.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Zephyr ESL-M90AS, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Zephyr ESL-M90AS. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Zephyr ESL-M90AS.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Zephyr ESL-M90AS, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Zephyr ESL-M90AS. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Zephyr ESL-M90AS.

El manual de instrucciones completo de Zephyr debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Zephyr ESL-M90AS - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Zephyr ESL-M90AS, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Zephyr ESL-M90AS que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Zephyr ESL-M90AS - que deben facilitarnos los primeros pasos durante el uso de Zephyr ESL-M90AS
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Zephyr ESL-M90AS
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Zephyr ESL-M90AS en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Zephyr ESL-M90AS?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Zephyr ESL-M90AS, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Zephyr ESL-M90AS probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)