Zephyr ESL-M90AS - page 1
JAN06.0101 ...
-
Zephyr ESL-M90AS - page 2
2 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING . INST AL LA TION MUST COMPL Y WITH ALL LOCAL CODES. IMP ORT ANT : Save these Instructions for the Local Electrical Inspector s use. INS T ALLER: Please leave these Instructions with this unit for the owner . OWNER: Please ret ain these instructions for future reference. Safety W arning: T urn ...
-
Zephyr ESL-M90AS - page 3
3 www .zephyronline.com T able of Content s Import ant safet y Notice ..................................................................... 4 Electrical & Installa tion requir ements ............................................. 5 Electrical requirements .............................................................. 5 Before installing the hood ...
-
Zephyr ESL-M90AS - page 4
4 Import ant safety Notice CAUTION: FOR GENERAL VENTILA TING USE ONL Y . DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MA TERIALS OR VA P O R S . W ARNING T O REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, O R INJURY T O PERSONS, OBSER VE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer . If you have questions, contact the m ...
-
Zephyr ESL-M90AS - page 5
5 www .zephyronline.com Electrical & Inst allation requirement s ELECTRICAL REQUIREMENTS Important: Observe all governing codes and ordinances. It is the customers responsibility: T o co nt act a qualified electrical inst all er . T o assure that the electrical installation is adequate and in conformance with National Electrical Code ...
-
Zephyr ESL-M90AS - page 6
6 List of Materials PARTS SUPPLIED: Blower unit housing Hood canopy Met al filter x 1 Halogen light bulb x 2 Duct covers Remote Control Duct Cover support bracket (3 pieces to assemble) Hardware Packet: 4x8 screws x 4 (to assemble Duct cover support bracket) 6x70 screws x 2 (to fix Duct Cover support bracket) 10x60 w ...
-
Zephyr ESL-M90AS - page 7
7 www .zephyronline.com 1/2" 2"min 8" 7/16* Side Cabinet Side Cabinet 35" 7/16 min. cabinets opening wid ths 24" to 32" bottom of canopy to cooking surface ceiling CenterLine 1 1" 1/2 21" 1/8 11 " 11 " Ducting and conduit area passage(Duct bends are not considered) max 51" 15/16 * min 36" ...
-
Zephyr ESL-M90AS - page 8
8 Ducting version Non-vented (recirculating) version B B B Pipe Pipe Pipe F-H- G Inst allation Instructions Closely follow the instructions set out in this manual. All responsibility , for any eventu al inc onve nien ces, damage s or fires caused by not comp lyin g with the instru ctio ns in this manual, is declined. VENTING METHODS The hood is equ ...
-
Zephyr ESL-M90AS - page 9
9 www .zephyronline.com Inst allation - Ductwork Calculation Sheet 3 1/4 x 10 Rect., straight 6 Round,, straight 7", 8 Round,, straight 3 1/4 x 10 Rect.90° elbow 3 1/4 x 10 Rect.45° elbow 3 1/4 x 10 Rect.90° flat elbow 3 1/4 x 10 Rect. wall cap with damper 3 1/4 x 10 Rect.to 6 round trans ...
-
Zephyr ESL-M90AS - page 10
10 Inst allation Assembling the duct cover support bracket (3 pa r t s ) : The three par t s should be fixed with 4 screws, the support extension is a djustable and should correspond to the internal width of the upper duct cover . = = X Duct cover support bracket X Upper Duct cover 1. If possible, disconnect and move freestan ding or slide-in range ...
-
Zephyr ESL-M90AS - page 11
11 www .zephyronline.com 10. Determine the required height for the conduit and cut a 1-1/4" (3.2 cm) hole at this location. Run wires through hole according the National Electrical Code or CSA S t andards and local codes and ordinances. There must be enough power supply cable from the fused disconnect (or circuit breaker) box to make the conne ...
-
Zephyr ESL-M90AS - page 12
12 d. Fasten the hood to the motor unit using 6 screws from the bottom (release the grease filter to access fixing points. 15. Hang hood with the 2 mounting hooks. W ARNING Excessive Weight Hazard - Use two or more people to move and install range hood. Failure to do so can result in back or other injury . 16. Level the appliance, using a carpenter ...
-
Zephyr ESL-M90AS - page 13
13 www .zephyronline.com 19. Electrical connection W ARNING Electrical Shock Hazard W arning: T urn off power circuit at the service panel before wiring this unit. 120 V AC, 15 or 20 Amp circuit required. ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GR ...
-
Zephyr ESL-M90AS - page 14
14 Inst allation 22. Install duct cover with 2 screws first on duct cover support bracket, then slide the duct lower section towards the bottom. 23. Fit co ntrol bal l wi th it s m olex plug on its housing and twist in place. a 15 ° OK! b c 24. Perform connection between plates from control ball and from electronic box. 25.Fold all cables and ...
-
Zephyr ESL-M90AS - page 15
15 www .zephyronline.com Description of the hood 1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp (position and nr . of lamps m ay v ary ) 5 Hood canopy 6 Duct cover 7 Air outlet (used for Ductless version only) 6 7 2 3 4 5 1 ...
-
Zephyr ESL-M90AS - page 16
16 Description of the hood - Control Ball CONTROLS Use the high suction speed in cases of concentrated kitchen vapours. It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to l eave in operation during cooking and for another 15 minutes approximately after terminating cooking. Description of control ball ...
-
Zephyr ESL-M90AS - page 17
17 www .zephyronline.com Description of the hood - Remote Control USING THE REMOTE CONTROL This device complies with p art 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause und ...
-
Zephyr ESL-M90AS - page 18
18 Maintenance Prior to any maintenance operation ensure that the cooker hood is disconnected from the power supply . CLEANING The cooker hood should be cleaned regularly internally and externally . For cleaning use a cloth moistened with a neutral liquid detergents. Avoid abrasive detergents. Warning: Failure to carry out the basic standards of th ...
-
Zephyr ESL-M90AS - page 19
19 www .zephyronline.com T rouble Shooting Af ter inst allation, the unit doesnt work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the light s are not. The hood is not venting out properly . Met al filter is vibrating. 1. The power source is not turned ON. 2. The power line and the cable locking connec ...
-
Zephyr ESL-M90AS - page 20
20 W arranty T O O BT AIN SERVICE UNDER W ARRANTY : or any Service Related Questions, please call: 1-888-880-8368 S taple your receipt here. Proof of the original purchase date is needed to obtain ser vic e under the warranty . T O O B T AIN SERVICE UNDER W ARRANTY : Y ou must present proof of original purchase date. Please keep a copy of your date ...
-
Zephyr ESL-M90AS - page 21
21 www .zephyronline.com List of Part s and Accessories Part Description Part# Part Description Part# Ductless Recirculating Kit charcoal replacement filter duct cover extension kit internal blower - 600 cfm in-line blower - 1 100 cfm EBI-600A EBN-1 1 00 A ZRC-00SA Z0F-C060 Z1C-00SL halogen bulb, 12V 20 W metal filter remote control (RF) remote con ...
-
Zephyr ESL-M90AS - page 22
22 ...
-
Zephyr ESL-M90AS - page 23
23 www .zephyronline.com ...
Do you have a question concerning Zephyr ESL-M90AS?
Use the form below