  • Central Pneumatic 40072 - page 1

    AIR ST APLER 1/4 ” CROWN, 18 GAUGE Models 40072 / 40073 / 97521 SET UP AND OPERA TING INSTRUCTIONS Visit our website at: http://www .harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright © 2007 by Harbor Freight T ools ® . All rights reserved. No portion of t ...

  • Central Pneumatic 40072 - page 2

    Page 2 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 SA VE THIS MANUAL Keep this manual for the safety warnings and precautions, assembly , operating, inspection, maintenance and cleaning procedures. Write the product’ s serial number in the back of the manual near the assembly diagram (or month and year o ...

  • Central Pneumatic 40072 - page 3

    Page 3 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 W ARNING – When using tools, basic precautions should always be followed, including the following: General a. T o reduce the risks of electric shock, re, and injury to persons, read all the instructions before using the tool. W ork area a. Keep the wo ...

  • Central Pneumatic 40072 - page 4

    Page 4 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 T ool use and care a. Use clamps or another practical way to secure and support the workpiece to a stable platform. Holding the work by hand or against the body is unstable and can lead to loss of control. b. Do not force the tool. Use the correct tool for ...

  • Central Pneumatic 40072 - page 5

    Page 5 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 SPECIFIC SAFETY INSTRUCTIONS 1. Operators and others in work area MUST wear ANSI-approved safety goggles with side shields during use. The employer is responsible to enforce the use of eye protection by the operator and others in the work area. 2. Keep  ...

  • Central Pneumatic 40072 - page 6

    Page 6 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 22. Obey the manual for the air compressor used to power this tool. 23. Install an in-line shutoff valve to allow immediate control over the air supply in an emergency , even if a hose is ruptured. 24. Do not engrave or stamp anything into the housing to p ...

  • Central Pneumatic 40072 - page 7

    Page 7 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 SPECIFICA TIONS Operating Pressure 60-100 PSI Staple Capacity 80 Staple Length / T ype 3 / 4 ” to 1- 1 / 2 ”, 1 / 4 ” Crown, .039-.042” Shank (18 Gauge) Air Inlet 1 / 4 ” NPT (18 TPI - male/female adapter included) Note: SKU’s 40072 and 97521 c ...

  • Central Pneumatic 40072 - page 8

    Page 8 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 With the T rigger held, carefully lift the nailer and press it against the workpiece again. The tool must not cycle (re) . If it fails to act in the manner explained in bold, have it repaired by a qualied service technician. Loading Staples A LWA Y S ...

  • Central Pneumatic 40072 - page 9

    Page 9 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 3. FIGURE 2 Safety (52) Safety Cover (54) Lift the Safety Cover (54) off the top of the stapler - see Figure 2 . 4. FIGURE 3 Driver (19) Driver Cover (57) Carefully slide the Driver Cover (57) off around the Safety (52) and remove the jammed staple - see F ...

  • Central Pneumatic 40072 - page 10

    Page 10 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 Note: Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts. P ARTS LIST PLEASE READ THE FOLLOWING CAREFULL Y THE MANUF ACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE P ARTS DIAGRAM IN THIS MAN ...

  • Central Pneumatic 40072 - page 11

    Page 1 1 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 ASSEMBL Y DIAGRAM ...

  • Central Pneumatic 40072 - page 12

    Page 12 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 90 Day W arranty Harbor Freight T ools Co. makes every ef fort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the perio ...

Fabricante Central Pneumatic Categoría Staple Gun

Los documentos del dispositivo Central Pneumatic 40072 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Central Pneumatic
- manuales de instrucciones 40072
- hojas de producto Central Pneumatic
- folletos informativos
- o etiquetas energéticas Central Pneumatic 40072
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Central Pneumatic 40072.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Central Pneumatic 40072, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Central Pneumatic 40072. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Central Pneumatic 40072.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Central Pneumatic 40072, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Central Pneumatic 40072. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Central Pneumatic 40072.

El manual de instrucciones completo de Central Pneumatic debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Central Pneumatic 40072 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Central Pneumatic 40072, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Central Pneumatic 40072 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Central Pneumatic 40072 - que deben facilitarnos los primeros pasos durante el uso de Central Pneumatic 40072
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Central Pneumatic 40072
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Central Pneumatic 40072 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Central Pneumatic 40072?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Central Pneumatic 40072, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Central Pneumatic 40072 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)