Manuale per l’uso Central Pneumatic 40072

12 pagine 1.07 mb
Scarica

Vai alla pagina of 12

Summary
  • Central Pneumatic 40072 - page 1

    AIR ST APLER 1/4 ” CROWN, 18 GAUGE Models 40072 / 40073 / 97521 SET UP AND OPERA TING INSTRUCTIONS Visit our website at: http://www .harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright © 2007 by Harbor Freight T ools ® . All rights reserved. No portion of t ...

  • Central Pneumatic 40072 - page 2

    Page 2 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 SA VE THIS MANUAL Keep this manual for the safety warnings and precautions, assembly , operating, inspection, maintenance and cleaning procedures. Write the product’ s serial number in the back of the manual near the assembly diagram (or month and year o ...

  • Central Pneumatic 40072 - page 3

    Page 3 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 W ARNING – When using tools, basic precautions should always be followed, including the following: General a. T o reduce the risks of electric shock, re, and injury to persons, read all the instructions before using the tool. W ork area a. Keep the wo ...

  • Central Pneumatic 40072 - page 4

    Page 4 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 T ool use and care a. Use clamps or another practical way to secure and support the workpiece to a stable platform. Holding the work by hand or against the body is unstable and can lead to loss of control. b. Do not force the tool. Use the correct tool for ...

  • Central Pneumatic 40072 - page 5

    Page 5 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 SPECIFIC SAFETY INSTRUCTIONS 1. Operators and others in work area MUST wear ANSI-approved safety goggles with side shields during use. The employer is responsible to enforce the use of eye protection by the operator and others in the work area. 2. Keep  ...

  • Central Pneumatic 40072 - page 6

    Page 6 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 22. Obey the manual for the air compressor used to power this tool. 23. Install an in-line shutoff valve to allow immediate control over the air supply in an emergency , even if a hose is ruptured. 24. Do not engrave or stamp anything into the housing to p ...

  • Central Pneumatic 40072 - page 7

    Page 7 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 SPECIFICA TIONS Operating Pressure 60-100 PSI Staple Capacity 80 Staple Length / T ype 3 / 4 ” to 1- 1 / 2 ”, 1 / 4 ” Crown, .039-.042” Shank (18 Gauge) Air Inlet 1 / 4 ” NPT (18 TPI - male/female adapter included) Note: SKU’s 40072 and 97521 c ...

  • Central Pneumatic 40072 - page 8

    Page 8 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 With the T rigger held, carefully lift the nailer and press it against the workpiece again. The tool must not cycle (re) . If it fails to act in the manner explained in bold, have it repaired by a qualied service technician. Loading Staples A LWA Y S ...

  • Central Pneumatic 40072 - page 9

    Page 9 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 3. FIGURE 2 Safety (52) Safety Cover (54) Lift the Safety Cover (54) off the top of the stapler - see Figure 2 . 4. FIGURE 3 Driver (19) Driver Cover (57) Carefully slide the Driver Cover (57) off around the Safety (52) and remove the jammed staple - see F ...

  • Central Pneumatic 40072 - page 10

    Page 10 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 Note: Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts. P ARTS LIST PLEASE READ THE FOLLOWING CAREFULL Y THE MANUF ACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE P ARTS DIAGRAM IN THIS MAN ...

  • Central Pneumatic 40072 - page 11

    Page 1 1 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 ASSEMBL Y DIAGRAM ...

  • Central Pneumatic 40072 - page 12

    Page 12 For technical questions, please call 1-800-444-3353. SKU’s 40072, 40073, & 97521 90 Day W arranty Harbor Freight T ools Co. makes every ef fort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the perio ...

Fabbricante Central Pneumatic Categoria Staple Gun

I documenti che otteniamo dal fabbricante del dispositivoCentral Pneumatic 40072 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Central Pneumatic
- manuali per l’uso 40072
- schede prodotto Central Pneumatic
- opuscoli
- o etichette energetiche Central Pneumatic 40072
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Central Pneumatic 40072.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Central Pneumatic 40072, manuali di manutenzione, brevi manuali o manuali utente Central Pneumatic 40072. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Central Pneumatic 40072.

Manuale completo del dispositivo Central Pneumatic 40072, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Central Pneumatic 40072 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Central Pneumatic 40072.

Il manuale per l’uso completo Central Pneumatic, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Central Pneumatic 40072 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Central Pneumatic 40072, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Central Pneumatic 40072 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Central Pneumatic 40072 - che ci dovrebbe aiutare nei primi passi durante l'uso Central Pneumatic 40072
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Central Pneumatic 40072
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Central Pneumatic 40072 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Central Pneumatic 40072?

Utilizza il modulo sottostante

Se non hai risolto il problema con Central Pneumatic 40072 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Central Pneumatic 40072 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)