    TECHNICAL GUIDE SPLIT -SYSTEM AIR CONDITIONERS 13 SEER – R- 410A – 1 PHASE MODELS: YCJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) Due to continuous pro duct improvement, spec ifications are subject to cha nge with ou t notice. Visit us on the web at www . yor k.com Additional rating informa tion can be foun d at www . ahridirectory .org W ARRANTY S t ...

  • York YCJD18 THRU 60 - page 2

    561908-YTG-A-0410 2 Johnson Controls Unitary Products All dimensions are in inche s. They are subject to ch ange with- out notice. Certified dimensions will be provi ded upon request. Physical and Electr ical Dat a MODEL YCJD18S41 S3(H) YCJD24S41 S3(H) YCJD30S41 S3(H) YCJD36S41 S3(H) YCJD42S41 S3(H) YCJD48S4 1 S3(H) YCJD60S 41 S3 Unit Supply V olta ...

  • York YCJD18 THRU 60 - page 3

    561908-YTG-A-0410 Johnson Controls Unitary Pro ducts 3 PROCEDURES: 1. Unit factory charge listed on the u nit nameplate includes r e frigerant for the condenser, the smallest evaporator and 15 feet of interconnecting line tub ing. 2. V erify the TXV and additional charge required for specific evaporator coil in the system using the abo ve table. 3. ...

  • York YCJD18 THRU 60 - page 4

    561908-YTG-A-0410 4 Johnson Controls Unitary Products COOLING CAP ACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL W RA TED CFM NET MBH SEER EER TOT AL SENS. 13 SEER AC WITH MA YCJD18S41S3(H) MA08B 17 FC/MC18B 600 17.5 12.9 13.00 1 1.00 YCJD24S41S3(H) MA08B 17 FC/MC36B 800 24.0 16.7 13.00 1 1.00 MA08B 17 FC/MC35B 800 ...

  • York YCJD18 THRU 60 - page 5

    561908-YTG-A-0410 Johnson Controls Unitary Pro ducts 5 — = Not applicable. 13 SEER AC WITH AHP / SHP / AHX / F*FP YCJD18S41S3(H) AHP18 17 – 650 17.5 12.9 13.00 1 1.00 AHX18 17 - 630 18.0 13.8 14.50 12.00 F4FP024 18 – 600 17.5 12.9 13.00 1 1.00 F6FP018 17 - 600 17.8 13.3 14.50 12.00 YCJD24S41S3(H) AHP30 17 – 795 24.0 16.8 13.00 1 1.00 AHX30 ...

  • York YCJD18 THRU 60 - page 6

    561908-YTG-A-0410 6 Johnson Controls Unitary Products COOLING CAP ACITY - Upflow , Downflow & Horizontal Furnace s and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (Min.-max.) W RA TED CFM NET MBH SEER 1 EER TOT AL SENS. YCJD18S41S3(H) 450 - 750 14,17 FC/MC/PC18 600 17 .5 12 .9 13.00 1 1.00 450 - 750 14 HC18 600 17.5 12.9 13.00 1 1.0 ...

  • York YCJD18 THRU 60 - page 7

    561908-YTG-A-0410 Johnson Controls Unitary Pro ducts 7 COOLING CAP ACITY - With High Efficiency Motor Furnaces MODELS FURNACE MODEL COIL MODEL 1 W COOLING RA TED CFM Net MBH SEER EER TOT AL SE N S. 13 SEER HP WITH V ARIABLE SPEED FURNACES 2 YCJD18S41S3(H) T*(8,L)X*A12 FC/MC/PC18A 14 540 17.7 12.9 14.50 12.50 T*(8,L)X*B12 FC/MC/PC18B 17 580 18.0 13. ...

  • York YCJD18 THRU 60 - page 8

    561908-YTG-A-0410 8 Johnson Controls Unitary Products YCJD30S41S3(H) T*9X*C20 FC/MC/PC43C 21 720 28.2 19 .3 14 .00 12 .00 (Y*(8,L)C/T*8V)*A12 FC/MC/PC32A 14 1045 29.2 21.8 13.20 1 1.00 (Y*(8,L)C/T*8V)*B12 FC/MC/PC35B 17 995 29.6 21.4 14.00 1 1.50 (Y*9C/T*9V)*B12 FC/MC/PC35B 17 1045 29 .4 22.0 13.50 1 1.50 (Y*(8,L)C/T*8V)*C16 FC/MC/PC35C 21 1025 29. ...

  • York YCJD18 THRU 60 - page 9

    561908-YTG-A-0410 Johnson Controls Unitary Pro ducts 9 YCJD36S41S3(H) (Y*(8,L)C/T*8V)*C20 HC4 2 21 1 190 35.6 25.6 14.00 12.00 (Y*9C/T*9V)*C16 HC42 21 1240 35.4 25.2 13.50 1 1.50 (Y*9C/T*9V)*C20 HC42 21 1200 35.6 25.4 14.00 1 1.50 (Y*(8,L)C/T*8V)*C16 UC48C 21 1210 34.6 24.8 13.50 1 1.50 (Y*(8,L)C/T*8V)*C20 UC48C 21 1 155 34.8 24.8 14.00 1 1.50 (Y*9 ...

  • York YCJD18 THRU 60 - page 10

    561908-YTG-A-0410 10 Johnson Controls Unitary Products YCJD48S41S3(H) T*9X*C20 FC/PC60C 21 1625 47.0 34.6 13.40 1 1.00 T*9X*D20 FC/MC/PC60D 24 1490 47.5 33.8 13.20 1 1.00 T*9X*C16 FC/PC60C 21 1575 47.0 33.8 13.10 1 1.00 T*9X*C20 FC/PC60C 21 1625 47.0 33.8 13.10 1 1.00 (Y*(8,L)C/T*8V)*C16 FC/MC/PC48C 21 1565 49.0 35.0 13.10 1 1.00 (Y*(8,L)C/T*8V)*C2 ...

  • York YCJD18 THRU 60 - page 11

    561908-YTG-A-0410 Johnson Controls Unitary Pro ducts 11 ACCESSORIES Refer to Price Manua l for specific model numbers. Off Cycle Timer Delay - Provides a 5-minu te off cycle to pre- vent rapid recycling of the compressor . Hard St art Kit - Required when using TXV indoor coil. Also , provides increased starting torque for areas with low voltage. Th ...

  • York YCJD18 THRU 60 - page 12

    561908-YTG-A-0410 12 Johnson Controls Unitary Products Multipliers for determining the p erfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity incr eases by 1060 BTUH per 1000 CFM per degree above the list ed temperature and decr eases by 1060 BTUH per 1000 CFM pe ...

  • York YCJD18 THRU 60 - page 13

    561908-YTG-A-0410 Johnson Controls Unitary Pro ducts 13 Multipliers for determining the perform ance with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (between 73-87 F), sensible capacity increase s by 1060 BTUH per 1000 CFM per degree above the li sted temperature and decrease s by 1060 BTUH per 1000 CFM per ...

  • York YCJD18 THRU 60 - page 14

    561908-YTG-A-0410 14 Johnson Controls Unitary Products Multipliers for determining the p erfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity incr eases by 1060 BTUH per 1000 CFM per degree above the list ed temperature and decr eases by 1060 BTUH per 1000 CFM pe ...

  • York YCJD18 THRU 60 - page 15

    561908-YTG-A-0410 Johnson Controls Unitary Pro ducts 15 Multipliers for determining the perform ance with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (between 73-87 F), sensible capacity increase s by 1060 BTUH per 1000 CFM per degree above the li sted temperature and decrease s by 1060 BTUH per 1000 CFM per ...

  • York YCJD18 THRU 60 - page 16

    561908-YTG-A-0410 16 Johnson Controls Unitary Products Multipliers for determining the p erfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity incr eases by 1060 BTUH per 1000 CFM per degree above the list ed temperature and decr eases by 1060 BTUH per 1000 CFM pe ...

  • York YCJD18 THRU 60 - page 17

    561908-YTG-A-0410 Johnson Controls Unitary Pro ducts 17 Multipliers for determining the perform ance with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (between 73-87 F), sensible capacity increase s by 1060 BTUH per 1000 CFM per degree above the li sted temperature and decrease s by 1060 BTUH per 1000 CFM per ...

  • York YCJD18 THRU 60 - page 18

    Subject to change without notice. Published in U .S.A. 561908-YTG-A-0410 Copyright © 2010 by Johnson Controls, Inc. All rights reserved. Supersedes: 364834-YTG-H-0509 Johnson Controls Unitary Products 5005 Y ork Drive Norman, OK 73069 Multipliers for determining the p erfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif fer ...

Fabricante York Categoría Air Conditioner

Los documentos del dispositivo York YCJD18 THRU 60 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos York
- manuales de instrucciones YCJD18 THRU 60
- hojas de producto York
- folletos informativos
- o etiquetas energéticas York YCJD18 THRU 60
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones York YCJD18 THRU 60.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje York YCJD18 THRU 60, instrucciones de servicio, instrucciones cortas o instrucciones de usuario York YCJD18 THRU 60. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto York YCJD18 THRU 60.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo York YCJD18 THRU 60, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar York YCJD18 THRU 60. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de York YCJD18 THRU 60.

El manual de instrucciones completo de York debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual York YCJD18 THRU 60 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice York YCJD18 THRU 60, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de York YCJD18 THRU 60 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo York YCJD18 THRU 60 - que deben facilitarnos los primeros pasos durante el uso de York YCJD18 THRU 60
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con York YCJD18 THRU 60
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de York YCJD18 THRU 60 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de York YCJD18 THRU 60?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con York YCJD18 THRU 60, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con York YCJD18 THRU 60 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)