    User’s Manual OPT-6125 Series Handheld CCD Scanner 25-ULGPMU01-01 April 2002 Keyboard Wedge Interface USB Interface RS232 Interface 8 Olympic Drive Orangeburg, NY 10962 Tel 845.365.0090 Fax 845.365.1251 www.opticonUSA.com ...

  • Opticon OPT-6125 - page 2

    ...

  • Opticon OPT-6125 - page 3

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 3 Table of Contents PART I CCD Scanning General Information ...........................................4 Unpacking Factory Technical Support Part II Installation and SetUp A. Installation –Wedge Interface ……………5 Reset all Defaults ………… …………………………? ...

  • Opticon OPT-6125 - page 4

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 4 Part I General Information The OPT-6125 Series CCD Scanners util iz e state-of-the-art imaging tec hnology similar to that fo und in digital cameras, facsimile machines and video camcorders. The scanner images th e bar code la bel, then converts the digital signals into data the host ...

  • Opticon OPT-6125 - page 5

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 5 Part II Installation and SetUp This section of the m anual contains i nformation o n the physi cal installation of the scanner as well as certain programming opti ons. There is a separate section for eac h type of interface. C heck to see which type of interface your scanner has and t ...

  • Opticon OPT-6125 - page 6

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 6 Reset All Defaults – Ke yboad Wedge Interface Our scanners are shippe d with facto ry default settings that represe nt the settings m ost com monly used by our cust omers. In m ost applications, the scanner will work right out of the box without any ne ed for additional programming. ...

  • Opticon OPT-6125 - page 7

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 7 Intercharacter Delay for Keyboard Wedge interface The scanner may send data faster than the com puter or applica tion program can accept. This is called "keyboard buffer overrun" . If data appears to be missing, random read errors occur or the scanner locks up and will not s ...

  • Opticon OPT-6125 - page 8

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 8 B.) Installation – RS232 Interface The RS-232 scanner cable is terminated in with a DB9 female co nnector. An external power supply ( +5V DC) may be necessary. There is a power s upply jack on the RS-232 connector. Installation is as follows: 1. Plug the scanner into an RS 232 seria ...

  • Opticon OPT-6125 - page 9

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 9 RS-232C Communica tion Parameters Handshaking Protocol ZZ Start Program Menu -[[- P0 None -Q1- Β HP04 RTS/CTS +IQ15+ P3 ACK/NAK -Q!- ZG Xon/Xoff -[H- I0 Flow Control Time Unlimited -J1- Β I1 Flow Control: 100ms -J2- I2 Flow Control: 200ms -J3- I3 Flow Control: 400ms -J!- Baud Rate K ...

  • Opticon OPT-6125 - page 10

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 10 Data Bits / Stop Bits / Parity L0 7 Data Bits -M1- L1 8 Data Bits -M2- Β L5 1 Stop Bit -M6- Β L6 2 Stop Bits -M7- L3 Even Parity -M!- L4 Odd Parity -M5- L2 Mark No Parity -M3- Β ZZ End Program Menu ,ZZ, ...

  • Opticon OPT-6125 - page 11

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 11 C.) Installation – USB Interface Plug the scanner into the USB connector on your host computer. PC must be running Wind ows 98 or higher or iMac Rev A or higher. The computer will sense the presence of th e scanner and load any requ ired software drivers automatically. Reset All De ...

  • Opticon OPT-6125 - page 12

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 12 Part III Bar Code Menu Functions Section A Programming the Scanner This manual co ntains info rmation that allows you t o easily change ce rtain prog rammable param eters of t he scanner. The scanner is rea dy to use - no additi onal programm ing is requi red in most si tuations. The ...

  • Opticon OPT-6125 - page 13

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 13 Symbology Selection ZZ Start/End Program Menu -[[- A0 Read all codes -B1- Β A2 Code 39 only -B3- A3 Codabar only -B!- A4 IATA only -B5- A5 Code 93 only -B6- A6 Code 128 only -B7- A7 MSI/Plessey only -B8- A9 Telepen only -B:- AB Matrix 2of5 only -BC- J0 All UPC and EAN only -K1- J1 U ...

  • Opticon OPT-6125 - page 14

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 14 Symbology S election (c ontinued) ZZ Start/End Program Menu -[[- J2 UPC+2 only -K3- J3 UPC+5 only -K!- J4 EAN only -K5- J5 EAN+2 only -K6- J6 EAN+5 only -K7- J7 Industrial 2of5 only -K8- J8 Interleaved 2of5 only -K9- JD Trioptics only -KE- These options do not influen ce the reading ...

  • Opticon OPT-6125 - page 15

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 15 Symbology Additions If scanner will not be used to read all symbolog ies (default setting), sp eed operation by using this menu to add only the specific sym bologies bei ng used (a dd only the symbol ogies that are re quired). ZZ Start/End Program Menu -[[- B0 Disable all -C1- B2 Ena ...

  • Opticon OPT-6125 - page 16

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 16 Symbology Addi tions (con tinued) ZZ Start/End Program Menu -[[- R4 Enable EAN -S5- R5 Enable EAN+2 -S6- R6 Enable EAN+5 -S7- R7 Enable Industrial 2of5 -S8- R8 Enable Interleaved 2of5 -S9- ...

  • Opticon OPT-6125 - page 17

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 17 Setting the Number of Characters to be Scanned ZZ Start/End Program Menu -[[- H0 Fixed length OFF all codes -I1- Β H1 Fixed length ON all codes -I2- HK Fixed length ON selected codes -IL- HL Min. length selected codes -IM- HM Max. length selected codes -IN- Setting Code Specific Opt ...

  • Opticon OPT-6125 - page 18

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 18 UPC Settings Options f or UPC-A a nd UPC-E ba r codes. NOTE : Abbreviations: Xmit = transmit; CD = Check digit; CC = Country code ZZ Start/End Program Menu -[[- E2 UPC-A as EAN13 w/ CD (13 digits) -F3- E3 UPC-A w/ CD (12 digits) -F!- % E4 UPC-A w/ CD (12 digits) -F5- E5 UPC-A w/o CD ...

  • Opticon OPT-6125 - page 19

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 19 UPC Settings (c ontinued) Options for UPC-A - The UPC-A symbolo gy is a fixe d lengt h symbol ogy enco ding 11 data digits, a check di git and non printable start/stop ch aracters. Supported characters are num eric digit s 1 to 9. An optional leading zero can be transmitted which, to ...

  • Opticon OPT-6125 - page 20

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 20 EAN-13 and EAN-8 Settings ZZ Start/End Program Menu -[[- 6K EAN-13 transmit CD -7L- % 6J EAN-13 do not transmit CD -7K- 6I EAN-8 transmit CD -7J- % 6H EAN-8 do not transmit CD -7I- IB Disable ISBN translation -JC- % IA Enable ISBN translation -JB- IK Enable ISBN if possible -JL- HN D ...

  • Opticon OPT-6125 - page 21

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 21 EAN-13 and EAN-8 Setting s EAN-13 is a fixed le ngth sym bology enco ding 12 dat a digits, a check di git and no n printable st art/stop c haracters. Supported c haracters a re numeric digits 0 t o 9. The dat a may be t ranslated i nto ISBN or ISSN form at. String format: data (12 di ...

  • Opticon OPT-6125 - page 22

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 22 Code 39 Settings ZZ Start/End Program Menu -[[- C0 Check CD -D1- C1 Do not check CD -D2- % D0 Xmit ST/SP -E1- D1 Do not xmit ST/SP -E2- % D4 Full ASCII -E%- D5 Normal Code 39 -E6- % D8 Do not xmit CD -E9- D9 Xmit CD -E:- % +K Full ASCII Code 39 if possible -,L- +L Enable concat-enati ...

  • Opticon OPT-6125 - page 23

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 23 8D Minimum 3 digits -9E- 8E Minimum 1 digit -9F- CONTINUED O N NEXT P AGE... ...

  • Opticon OPT-6125 - page 24

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 24 Code 39 Settings (continued) Code 39 is a variable length symbology with an optional check digit ("CD") and printab le start/stop ("ST/SP") characters. The following characters are supported: • Numeric characters 0 to 9 • Alpha characters capital A to Z • Sp ...

  • Opticon OPT-6125 - page 25

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 25 Codabar Settings ZZ Start/End Program Menu -[[- F0 Do not transmit start/stop -G1- % F1 Transmit start/stop as ABCD/TN* E -G2- F2 Transmit start/stop as abcd/tn*e -G3- F3 Transmit start/stop as ABCD/ABC D -G!- F4 Transmit start/stop as abcd/abcd -G5- H3 Enable Codabar, ABC and CX -I! ...

  • Opticon OPT-6125 - page 26

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 26 CONTINUED ON NEXT PAGE... ...

  • Opticon OPT-6125 - page 27

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 27 Codabar Settings (continued) ZZ Start/End Program Menu -[[- HA Enable Codabar normal mode only -IB- % HB Min. data 3 chars. -IC- HC Min. data 1 char. -ID- HD Enable space insertion -IE- HE Disable space insertion -IF- % HF Min. data 5 chars. -IG- % HH Enable interchar. gap check -II- ...

  • Opticon OPT-6125 - page 28

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 28 * start/stop characters are A, B, C or D The checksum is calculated as t he sum m odulo 16 of t he numerical values of all data characters. String format: start char. data (1 or more chars.) check digit stop char. CONTINUED O N NEXT P AGE... ...

  • Opticon OPT-6125 - page 29

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 29 Codabar Settings (continued) ABC-Code - The ABC code i s an acrony m for Am erican Blo od Commi ssion. The code consists of two bar codes which are decoded in one read cycle. the code is concate nat ed when the stop c haracter of the first bar co de and the start character of the sec ...

  • Opticon OPT-6125 - page 30

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 30 2of5 Settings ZZ Start/End Program Menu -[[- E0 Transmit CD -F1- % E1 Do not transmit CD -F2- G0 Do not check CD -H1- % G1 Check CD -H2- GE Min. data 1 char. -HF- GF Min. data 3 chars. -HG- GI Min. data 5 chars. -GJ- % GJ Enable space check for Industrial 2of5 -GK- % GK Disable space ...

  • Opticon OPT-6125 - page 31

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 31 2of5 Settings (c ontinued) Code 2of5 is a variable length symbolog y with an optional ch eck digit a nd non pri ntable start and stop character. Supported c haracters i nclude num eric digits 0 to 9. The checksum is calculated as t he sum m odulo 10 of t he numerical values of all th ...

  • Opticon OPT-6125 - page 32

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 32 MSI/Plessey Settings ZZ Start/End Program Menu -[[- 4A Do not check CD -5B- 4B Check 1 CD = Mod 10 -5C- % 4C Check 2 CD's = Mod 10 /Mod 10 -%D- 4D Check 2 CD's = Mod 10 /Mod 11 -5E- 4E Transmit CD1 -5F- % 4F Transmit CD1 and CD2 -5G- 4G Do not transmit CD -5H- 4R Check 2 CD ...

  • Opticon OPT-6125 - page 33

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 33 Check digit - If the check di git calculation is required, t hen the appr opriate calculati on method m ust be select ed. Do not transmit CD - The charac ter position s CD1 and CD2 ar e not transmitted . Transmit CD1 - The character position CD2 is no t transmitted. Transmit CD1 and ...

  • Opticon OPT-6125 - page 34

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 34 Code 128, EAN 128 Settings ZZ Start/End Program Menu -[[- JF Enable EAN 128 only -KG- MO Enable FNC2 concat-enation -NP- MP Disable FNC2 concat-enation -NQ- % OF Disable EAN 128 -PG- % OG Enable EAN 128 if possible -PH- Code 128 is a variable l ength sym bology wi th a m andatory che ...

  • Opticon OPT-6125 - page 35

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 35 FNC2 Concat enation - If a Code 128 bar code contains a leadi ng FNC2 character, the data is stored into the reader's buffer. As soon a s a Code 128 bar code is read without a leading FN C2 character, the data is appended to the reader's buffer and the entire bu ffer is tra ...

  • Opticon OPT-6125 - page 36

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 36 IATA Settings ZZ Start/End Program Menu -[[- 4H Do not check CD -!5I- % 4I Check S/N only -5J- 4J Check CPN, S/N -5K- 4K Check CPN, airline and S/N -5L- 4L Transmit CD -5M- % 4M Do not transmit CD -5N- IATA is a variabl e length sy mbology with an o ptional chec k digit a nd non prin ...

  • Opticon OPT-6125 - page 37

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 37 Telepen Settings ZZ Start/End Program Menu -[[- D2 Numeric mode -E3- % D3 ASCII mode -E!- Telepen is a variable length sym bology with a check di git and non printable star t/stop characters. Supported characters include numeric dig its 00 th rough 99 i n numeric mode, and all 128 AS ...

  • Opticon OPT-6125 - page 38

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 38 Case Conversion ZZ Start/End Program Menu -[[- YZ No case conversion -Z[- % YW Convert to upper case -ZX- YX Convert to lower case -ZY- YY Exchange case -ZZ- String Options - This section describes the alteratio ns which can be made to the format of the transmitted data string. Optio ...

  • Opticon OPT-6125 - page 39

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 39 Setting a Prefix or Suffix A Prefix and Su ffix consi sting of a maxim um 4 direct inp ut entries eac h may be incl uded in fro nt and at the end of the string, respectively. The following steps are u sed to establish a Prefix or Suffix that will be transmitted with th e bar code dat ...

  • Opticon OPT-6125 - page 40

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 40 Prefix Settings (continued) ZZ Start/End Program Menu -[[- M7 Interleaved 2of5 -N8- M8 Code 93 -N9- M9 Code 128 -N:- N0 MSI/Plessey -O1- N1 UPC-A -O2- N2 UPC-E -O3- N3 EAN-13 -O!- N4 EAN-8 -O5- RY All codes -SZ- MG Clear all prefixes -NH- MZ Preamble -N[- ...

  • Opticon OPT-6125 - page 41

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 41 Suffix Settings ZZ Start/End Program Menu -[[- GM Matrix 2of5 -HN- I9 IATA -J:- L9 Telepen -M:- N5 MSI/Plessey -O6- N6 UPC-A -O7- N7 UPC-E -O8- N8 EAN-13 -O9- N9 EAN-8 -O:- O0 UPC-A + add-on -P1- O1 UPC-E + add-on -P2- O2 EAN-13 + add-on -P3- O3 EAN-8 + add-on -P!- O4 Code 39 -P5- O5 ...

  • Opticon OPT-6125 - page 42

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 42 Suffix Settings (continued) ZZ Start/End Program Menu -[[- O6 Industrial 2of5 -P7- O7 Interleaved 2of5 -P8- O8 Code 93 -P9- O9 Code 128 -P:- PR Clear all suffixes -QS- PS Postamble -QT- RZ All Codes -S[- ...

  • Opticon OPT-6125 - page 43

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 43 Direct Input Keyboard Keys ZZ Start/End Program Menu -[[- 8J F1 -9K- 8K F2 -9L- 8L F3 -9M- 8M F4 -9N- 8N F5 -9O- 8O F6 -9P- 8P F7 -9Q- 8Q F8 -9R- 8R F9 -9S- 8S F10 -9T- 8T F11 -9U- 8U F12 -9V- 9X Backspace -:Y- 7H TAB -8I- CONTINUED O N NEXT P AGE... ...

  • Opticon OPT-6125 - page 44

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 44 Direct Input Keyboard Keys (continued) ZZ Start/End Program Menu -[[- 7I Carriage return -8J- % 7Q Enter (numeric pad) -8R- 7R Enter make (alpha pad) -8S- 7S Enter make and break (alpha pad) -8E- 7J ESC -8K- 7K Arrow down -8L- 7L Arrow up -8M- 7M Arrow right -8N- 7N Arrow left -8O- 7 ...

  • Opticon OPT-6125 - page 45

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 45 Direct Input Keyboard Keys (continued) ZZ Start/End Program Menu -[[- 7P Page down -8Q- 7U Left <Shift> -8V- 7W Left <Ctrl> -8X- 7Y Left <Alt> -8Z- 7V Right <Shift> -8W- 7X Right <Ctrl> -8Y- 7Z Right <Alt> -8[- 9S CAPSLOCK -:T- ...

  • Opticon OPT-6125 - page 46

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 46 Direct Input Characters ZZ Start/End Program Menu -[[- 5A <SPACE> -6B- 5B ! -6C- 5C " -6D- 5D # -6E- 5E $ -6F- 5F % -6G- 5G & -6H- 5H ' -6I- 5I ( -6J- 5J ) -6K- 5K * -6L- 5L + -6M- 5M , -6N- 5N - -6O- CONTINUED O N NEXT P AGE... ...

  • Opticon OPT-6125 - page 47

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 47 Direct Input Characters (continued) ZZ Start/End Program Menu -[[- 5O . -6P- 5P / -6Q- 6A : -7B- 6B ; -7C- 6C < -7D- 6D = -7E- 6E > -7F- 6F ? -7G- 6G @ -7H- 7A [ -8B- 7B -8C- 7C ] -8D- 7D ^ -8E- 7E _ -8F- CONTINUED O N NEXT P AGE... ...

  • Opticon OPT-6125 - page 48

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 48 Direct Input Characters (continued) ZZ Start/End Program Menu -[[- 7F ` -8G- 9T { -:U- 9U | -:V- 9V } -:W- 9W ~ -:X- CONTINUED O N NEXT P AGE... ...

  • Opticon OPT-6125 - page 49

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 49 Direct Input Characters (continued) ZZ Start/End Program Menu -[[- Q0 0 -R1- Q1 1 -R2- Q2 2 -R3- Q3 3 -R!- Q4 4 -R5- Q5 5 -R6- Q6 6 -R7- Q7 7 -R8- Q8 8 -R9- Q9 9 -R:- 0A A -1B- 0B B -1C- 0C C -1D- CONTINUED O N NEXT P AGE... ...

  • Opticon OPT-6125 - page 50

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 50 Direct Input Characters (continued) ZZ Start/End Program Menu -[[- 0D D -1E- 0E E -1F- 0F F -1G- 0G G -1H- 0H H -1I- 0I I -1J- 0J J -1K- 0K K -1L- 0L L -1M- 0M M -1N- 0N N -1O- 0O O -1P- 0P P -1Q- 0Q Q -1R- CONTINUED O N NEXT P AGE... ...

  • Opticon OPT-6125 - page 51

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 51 Direct Input Characters (continued) ZZ Start/End Program Menu -[[- 0R R -1S- 0S S -1T- 0T T -1U- 0U U -1V- 0V V -1W- 0W W -1X- 0X X -1Y- 0Y Y -1Z- 0Z Z -1[- $A a -%B- $B b -%C- $C c -%D- $D d -%E- $E e -%F- CONTINUED O N NEXT P AGE... ...

  • Opticon OPT-6125 - page 52

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 52 Direct Input Char acters (c ontinued) ZZ Start/End Program Menu -[[- $F f -%G- $G g -%H- $H h -%I- $I i -%J- $J j -%K- $K k -%L- $L l -%M- $M m -%N- $N n -%O- $O o -%P- $P p -%Q/ $Q q -%R- $R r -%S- $S s -%T- CONTINUED O N NEXT P AGE... ...

  • Opticon OPT-6125 - page 53

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 53 Direct Input Characters (continued) ZZ Start/End Program Menu -[[- $T t -%U- $U u -%V- $V v -%W- $W w -%X- $X x -%Y- $Y y -%Z- $Z z -%[- ...

  • Opticon OPT-6125 - page 54

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 54 Direct Input Control Characters ZZ Start/End Program Menu -[[- 9G ^@(NULL) -:H- 1A ^A(SOH) -2B- 1B ^B(STX) -2C- 1C ^C(ETX) -2D- 1D ^D(EOT) -2E- 1E ^E(ENQ) -2F- 1F ^F(ACK) -2G- 1G ^G(BEL) -2H- 1H ^H(BS) -2I- 1I ^I(HT) -2J- 1J ^J(LF) -2K- 1K ^K(VT) -2L- 1L ^L(FF) -2M- 1M ^M(CR) -2N- CO ...

  • Opticon OPT-6125 - page 55

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 55 Direct Input Control Ch arac ters (continued) ZZ Start/End Program Menu -[[- 1N ^N(SO) -2O- 1O ^O(SI) -2P- 1P ^P(DLE) -2Q- 1Q ^Q(DC1) -2R- 1R ^R(DC2) -2S- 1S ^S(DC3) -2T- 1T ^T(DC4) -2U- 1U ^U(NAK) -2V- 1V ^V(SYN) -2W- 1W ^W(ETB) -2X- 1X ^X(CAN) -2Y- 1Y ^Y(EM) -2Z- 1Z ^Z(SUB) -2[- 9A ...

  • Opticon OPT-6125 - page 56

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 56 Direct Input Control Characters (continued) ZZ Start/End Program Menu -[[- 9B ^(FS) -:C- 9C ^](GS) -:D- 9D ^^(RS) -:E- 9E ^_(US) -:F- 9F DEL (ASCII 127) -:G- Direct Input Code ID/Length ZZ Start/End Program Menu -[[- $2 Code identification -%3- $3 Code length -%!- ...

  • Opticon OPT-6125 - page 57

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 57 Read Mode Settings ZZ Start/End Program Menu -[[- S0 Single read -T1- S1 Multiple read -T2- % S2 Continuous read -T3- XA Add-on wait mode disabled -YB- XB Add-on wait mode 0.25 sec. -TC- XC Add-on wait mode 0.50 sec. -YD- % XD Add-on wait mode 0.70 sec. -YE- Single Read - When a bar ...

  • Opticon OPT-6125 - page 58

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 58 Trigger Settings ZZ Start/End Program Menu -[[- S7 Disable trigger -T8- S8 Enable trigger -T9- Disable Tri gger - This is applicab le to readers which have a trig ger switch. When this option is selected, the reader will stay ON all the time. Multiple Read Reset Time ZZ Start/End Pro ...

  • Opticon OPT-6125 - page 59

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 59 Quiet Zone Settings ZZ Start/End Program Menu -[[- YN No margin check -ZO- YO Margin check 1/7 normal -ZP- YP Margin check 2/7 normal -ZQ- YQ Margin check 3/7 normal -ZR- YR Margin check 4/7 normal -ZS- YS Margin check 5/7 normal -ZE- YT Margin check 6/7 normal -ZU- YU Margin check n ...

  • Opticon OPT-6125 - page 60

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 60 Read Time Settings ZZ Start/End Program Menu -[[- Y0 0 seconds -Z1- Y1 1 second -Z2- Y2 2 seconds -Z3- % Y3 3 seconds -Z!- Y4 4 seconds -Z5- Y5 5 seconds -Z6- Y6 6 seconds -Z7- Y7 7 seconds -Z8- Y8 8 seconds -Z9- YL Read time x 10 -ZM- YM Indefinitely -ZN- Read Time Settings - the le ...

  • Opticon OPT-6125 - page 61

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 61 Redundant Decoding Settings ZZ Start/End Program Menu -[[- X0 No redundancy -Y1- X1 Two times redundant -Y2- % X2 Three times redundant -Y3- X3 Four times redundant -Y!- Redundancy Se ttings - This is the number of tim es that a label must be correctly decoded before it is transmitte ...

  • Opticon OPT-6125 - page 62

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 62 Buzzer Settings ZZ Start/End Program Menu -[[- W8 Enable software buzzer -X9- % W0 Disable buzzer -X1- W1 Single tone buzzer -X2- W2 High - low buzzer -X3- % W3 Low - high buzzer -X!- W7 Buzzer duration 50 msec. -X8- W4 Buzzer duration 100 msec. -X5- W5 Buzzer duration 200 msec. -X6- ...

  • Opticon OPT-6125 - page 63

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 63 T2 Buzzer volume normal -U3- T3 Buzzer volume minimum -U!- VY Buzzer before transmission -WZ- % CONTINUED O N NEXT P AGE... ...

  • Opticon OPT-6125 - page 64

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 64 Buzzer Settings ZZ Start/End Program Menu -[[- VZ Buzzer after transmission -W[- GD Disable startup buzzer -HE- GC Enable startup buzzer -HD- Buzzer Settings - These options determine the buzzer type, tone, duration and l oudness. By default, t he buzzer is disabled for Li nker type ...

  • Opticon OPT-6125 - page 65

    Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Page 65 Good Read LED ZZ Start/End Program Menu -[[- T4 Disable indicator -U5- T5 Indicator duration 0.2 sec. -U6- % T6 Indicator duration 0.4 sec. -U7- T7 Indicator duration 0.8 sec. -U8- Diagnostics ZZ Start/End Program Menu -[[- Z1 Transmit software version -[2- Z3 Transmit settings -[!- ...

Fabricante Opticon Categoría Scanner

Los documentos del dispositivo Opticon OPT-6125 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Opticon
- manuales de instrucciones OPT-6125
- hojas de producto Opticon
- folletos informativos
- o etiquetas energéticas Opticon OPT-6125
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Opticon OPT-6125.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Opticon OPT-6125, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Opticon OPT-6125. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Opticon OPT-6125.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Opticon OPT-6125, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Opticon OPT-6125. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Opticon OPT-6125.

El manual de instrucciones completo de Opticon debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Opticon OPT-6125 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Opticon OPT-6125, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Opticon OPT-6125 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Opticon OPT-6125 - que deben facilitarnos los primeros pasos durante el uso de Opticon OPT-6125
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Opticon OPT-6125
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Opticon OPT-6125 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Opticon OPT-6125?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Opticon OPT-6125, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Opticon OPT-6125 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)