    INST ALLA TION AND OPERA TING INSTRUCTIONS FOR AQ-1 POWER VENT KIT DESIGNED FOR BOSCH 425 HN W A TER HEA TERS AQUAST AR 125 B W A TER HEA TERS INCLUDING AQUAST AR MODELS: 125HX • 125BS • 125X • 125BL T ABLE OF CONTENTS contents with an AQ-1 power vent p. 1 mounting gas pressure switch p. 2 mounting linear spillage switch p.4 common setup p. 6 ...

  • AquaStar 125X - page 2

    AQ-1 Power vent kit Parts included: Spillage Switch Kit 1. 185º F linear spillage switch mounted on an angled bracket and equipped with 36 inch cables connected to one eyelet terminal and one 1/4" quick connect terminal 2. Spillage switch mounting screw 3. Push on male spade connector , replaces eyelet terminal from 36 inch spill switch cable ...

  • AquaStar 125X - page 3

    Power V ent Kit CAUTION 1. Failure to install, maintain and/or operate the Power V enter in accordance with manufacturer's instruction may result in conditions which can produce bodily injury and property damage. 2. The Power V enter must be installed by a qualified installer in accordance with all local codes or , in their absence, in accorda ...

  • AquaStar 125X - page 4

    INSTRUCTIONS ( SEE DIAGRAMS ABOVE ) 1. Mount gas pressure switch by securing it to the chosen location with a screw in each one of the four mounting holes. 2. Use a tube cutter to make a clean cut (not crimped) at each end of the two lengths of the 1/4" aluminum tubing. One tube must be long enough to reach from the fitting marked "connec ...

  • AquaStar 125X - page 5

    e. Hand thread the pressure tap fitting into the heater's burner manifold. Use a small amount of an appropriate thread sealant on the male end of the fitting. Over tightening of the fitting will break it. f. Guide the end of the tube into the com- pression fitting. While using one wrench to hold back the pressure tap fitting, gently snug- up t ...

  • AquaStar 125X - page 6

    1. The ECO is mounted on the lower left outlet water pipe. (See figure C) a. Remove one lead connecting to ECO terminal, it does not matter which one is disconnected. b. Attach 1/4" quick connect terminal end of linear spill switch cable to now exposed terminal of the ECO. c. Remove the eyelet ended terminal from the other spill switch cable. ...

  • AquaStar 125X - page 7

    COMMON SETUP Mount gas pressure switch against wall 6 125B Model shown See Figure D, page 5 for location of Linear S pillage Switch V ent Hood (see freeze prevention information on page 2) Power vent motor 4" single wall pipe* (galvanized or stainless steel) or 4" B-type vent*. * Single wall vent pipe requires a 6" clearance to combu ...

  • AquaStar 125X - page 8

    CAUTION Failure to follow these installation instructions may violate applicable national and/or local codes The vent system must terminate so that proper clearances are maintained as cited in the National Fuel Gas Code, ANSI Z223.1 "The exit terminals of mechanical vent system shall be located not less than 7 feet above grade when located adj ...

  • AquaStar 125X - page 9

    INSTRUCTIONS (DO NOT BEGIN THESE PROCEDURES UNTIL VENT HOOD HAS BEEN INST ALLED) 1. Remove vibration mounts, nuts and washers from parts bag. Install on power venter as shown in (Figure H). 2. T o prevent vibration, securely support power venter from ceiling or joist using a plumber's strap or wire fastened to the vibration mounts. As an alter ...

  • AquaStar 125X - page 10

    3. Connect the RED wire from the jacketed cable onto the common terminal of the gas pressure switch. (See Figure I) NOTE: If the distance between the power venter and the gas pressure switch is greater than the length of the cable, splice a section of 2 conductor , PVC sheathed, 105º C thermostat cable to the supplied cable. Make sure that the col ...

  • AquaStar 125X - page 11

    SAFETY INTERLOCK TEST 1. Open the gas supply to the water heater . 2. Remove the vent pipe from the vent connec- tor on the top of the water heater . 3. Block the vent connector with sheet metal or other noncombustible material. 4. Turn on the hot water supply to allow the burner to activate. Hot flue gasses will spill from the draft diverter momen ...

  • AquaStar 125X - page 12

    11 HEA TER ECO SAFET Y INTERLOCK DIAGRAM LINEAR LIMIT SPILLAGE SENSING SWITCH 185º MANUAL RESET BLACK ...

  • AquaStar 125X - page 13

    1. Attach this template to the interior of the wall the V ent Hood will be penetrating. 2. Insure that proposed vent termination clear- ances are met before cutting opening through wall. Using a 1/2" drill bit, drill two pilot holes where noted on this template. The drill bit must be long enough to penetrate to the building exterior . 3. Attac ...

Fabricante AquaStar Categoría Water Heater

Los documentos del dispositivo AquaStar 125X que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos AquaStar
- manuales de instrucciones 125X
- hojas de producto AquaStar
- folletos informativos
- o etiquetas energéticas AquaStar 125X
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones AquaStar 125X.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje AquaStar 125X, instrucciones de servicio, instrucciones cortas o instrucciones de usuario AquaStar 125X. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto AquaStar 125X.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo AquaStar 125X, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar AquaStar 125X. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de AquaStar 125X.

El manual de instrucciones completo de AquaStar debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual AquaStar 125X - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice AquaStar 125X, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de AquaStar 125X que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo AquaStar 125X - que deben facilitarnos los primeros pasos durante el uso de AquaStar 125X
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con AquaStar 125X
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de AquaStar 125X en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de AquaStar 125X?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con AquaStar 125X, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con AquaStar 125X probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)