    PROGRAMMABLE PROCESS MONITORS USER ’ S MANUAL DP3600, DP3700 AND DP3800 SERIE S OMEGA ENGINEERING, INC., ONE OMEGA DRIVE, STAMFORD, CT 06907. MANUAL: M881/0399 ...

  • Omega Engineering DP3600 - page 2

    1 SPECIFICATIONS ............................................................................................................................................................................................... 3 DESCRIPTION ............................................................................................................................... ...

  • Omega Engineering DP3600 - page 3

    2 SCALING .............................................................................................................................................................................................................. 12 OFFSET ........................................................................................................................... ...

  • Omega Engineering DP3600 - page 4

    3 SPECIFICATIONS (typical @ 25 C and rated supply voltage unless otherwise specified). STANDARD INPUT: * 4 - 20 MA, 10 - 50 MA, 0 - 5 VDC, 0 - 10 VDC EXTERNAL HOLD: * An external low level signal applied to the HOLD pin on the rear connector will initiate hold function. ANALOG TO DIGITAL CONVERSION: * 41/2 Digit A/D conversion. * Dual slope integra ...

  • Omega Engineering DP3600 - page 5

    4 DESCRIPTION The DP3600 series of instrumen ts are micro - processor based intelligent monitors that are capable of performing several tasks in addition to displaying the process variable. The micro - processor technology used in the system design has provided these instruments a cost and performance edge that is simply not possible with analog sy ...

  • Omega Engineering DP3600 - page 6

    5 PROGRAM LIMITS 1. Process Limit1 2. Process Limit2 3. Setup limt 3 f or Rate/Process 4. Process Limit 3 5. Setup Limit4 for Process/Deviation 6. Process Limit 4 7. Timer 1 Limit 8. Timer 2 Limit 9. Deadband for limits 9. Limits Normally open/close (1 Thru 4) 10. Limits Latching/Non Latching 11. Audio Alarm On/Off PROGRAM SYSTEM 1. Display Options ...

  • Omega Engineering DP3600 - page 7

    6 Offset: Next configurable function is offset and is indicated by the message ‘OFFSET’ followed by current offset value. To change the v alue of flashing digit press ^v key. To move the flashing digit, push <NXT> key. After programming the desired value of offset, push the "SETUP" key to get to the next function. Tare: Tare mod ...

  • Omega Engineering DP3600 - page 8

    7 Selection of Limit 4 as Process or Deviation Limit: This step comes after programming Limit 3 and is indicated by the message ‘LT3 Pr’ (if Limit 3 is setup as Process limit ) or ‘LT3 dEN’ (if Limit 3 is setup as deviation limit). Alternate selection can be made by pushing ^v key. Push SETUP key after making the selection. Programming Limi ...

  • Omega Engineering DP3600 - page 9

    8 Audio Alarm On/Off: This unit supports an audio alarm which comes on when ever a limit value is exceeded. This alarm can be turned On or Off, as desired. The selection is made by pushing ^v key. If the alarm is ON, the display will read ‘ALR ON’ (Alarm On). Alternately, it will display ‘ALR OFF’ (for ‘Alarm Off’). Pus h SETUP key afte ...

  • Omega Engineering DP3600 - page 10

    9 Rate Time - Base: This step is for programming time - base for calculation of Rate. Units of time - base are seco nds. Again, the active digit will be flashing. To change the value, push ^v key. To activate another digit for change, use <NXT> key. On finishing, push SETUP key. Remote Tare/Hold: Remote Tare/Hold feature lets you select betwe ...

  • Omega Engineering DP3600 - page 11

    10 SET UP FLOW CHART: SETUP SCALING (SCALING) HIGH SCALE (HI SCLE) LOW SCALE (LO SCLE) OFFSET (OFFSET) TARE (TARE) PROGRAM PROCESS LIMIT 1 (PrG Lt1 -- 01.234) PROGRAM PROCESS LIMIT 2 (PrG Lt2 -- 01.234) LIMIT 3 RATE OR PROCESS (Lt3 rtE) or (Lt3 Pr) PROGRAM LIMIT 3 VALUE (PrG Lt3 -- 02.123) LIMIT4 PROCESS / DEVIATION (Lt3 dEN) or (Lt3 Pr) TIMER 1 LI ...

  • Omega Engineering DP3600 - page 12

    11 MAX. AND MIN. READIN GS (PEAKS) Displaying: To display the peak values of Process variable push Peak key once and let go. The display will first indicate ‘ HIGH Pt’ briefly and then the value of the highest Process variable value monitored by the system. A second push while high peak is being displayed will bring up low peak value on the dis ...

  • Omega Engineering DP3600 - page 13

    12 PROCESS CHANGE Displaying: The system will constantly monitor the total amount of change in process variable since start or last reset. This change is displayable in engineering units by pushing the ‘PR CNG’ k ey. This function is useful in tracking the change that has taken place in the process e.g. in a tank containing 300 gallons of water ...

  • Omega Engineering DP3600 - page 14

    13 TARE Tare function is used for taking out a preset amount of process variable from the total reading e.g. if we are measuring weight of a certain p roduct being put in a container but do not want the weight of the container to show on the display, then enter the weight of the container as tare value. The DP3600 unit will then automatically subtr ...

  • Omega Engineering DP3600 - page 15

    14 Timer Limits: Displaying: To display timer limits, first push the TIME key. While still in this mode go on to push LIMITS key. The display will briefly show TR1 LT (for timer 1 Limit) and then the previously programmed value. Pushing the LIMITS key one more time will display TR2 LT followed by pre - programmed timer 2 value. Programming of timer ...

  • Omega Engineering DP3600 - page 16

    15 Open Collector Option Whenever a limit is reached an open collector output provides a 5 Vdc signal at 50ma. on the output connector, e.g... Limit 1 provides its 5 volt output signal between pins 1 and 2. Figure 2. Open Collector Hookup Example HOLD FUNCTION The hold function allows to freeze the Process Variable reading in the display window ind ...

  • Omega Engineering DP3600 - page 17

    16 PIN NO DESCRIPTION 1 LIMIT 1 COMMON/OPEN COLLECTOR POSITIVE 2 LIMIT 1 NORMALLY OPEN/OPEN COLLECTOR NEGA TIVE 3 LIMIT 2 COMMON/OPEN COLLECTOR POSITIVE 4 LIMIT 2 NORMALLY OPEN/OPEN COLLECTOR NEGATIVE 5 LIMIT 3 COMMON/OPEN COLLECTOR POSITIVE 6 LIMIT 3 NORMALLY OPEN/OPEN COLLECTOR NEGATIVE 7 LIMIT 4 COMMON/OPEN COLLECTOR P OSITIVE 8 LIMIT 4 NORMALLY ...

  • Omega Engineering DP3600 - page 18

    17 TROUBLE SHOOTING If the meter locks on a particular display, unplug and plug in again the meter to unlock the display. A total reset defaults all scaling values to zero. To perform thi s reset, re - apply power with RESET key pressed in. Factory preset values for Current, Voltage and millivolt, respectively, can be programmed by simply re - appl ...

  • Omega Engineering DP3600 - page 19

    18 A 1 2 3 4 3 B 3.62" (91.9mm) 1.70" 43.2mm NOT DRAWN TO SCALE Back of the Meter Bracket Screw Driver Push Meter this way with the Screwdriver MOUNTING 1. Cut a hole in panel to the specifications shown in the figure 4 : Figure 4. Panel Cutout Dimensions 2. Insert pannel meter into the hole until it is flush with the pannel. 3. Refer to ...

Fabricante Omega Engineering Categoría Computer Monitor

Los documentos del dispositivo Omega Engineering DP3600 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Omega Engineering
- manuales de instrucciones DP3600
- hojas de producto Omega Engineering
- folletos informativos
- o etiquetas energéticas Omega Engineering DP3600
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Omega Engineering DP3600.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Omega Engineering DP3600, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Omega Engineering DP3600. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Omega Engineering DP3600.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Omega Engineering DP3600, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Omega Engineering DP3600. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Omega Engineering DP3600.

El manual de instrucciones completo de Omega Engineering debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Omega Engineering DP3600 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Omega Engineering DP3600, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Omega Engineering DP3600 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Omega Engineering DP3600 - que deben facilitarnos los primeros pasos durante el uso de Omega Engineering DP3600
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Omega Engineering DP3600
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Omega Engineering DP3600 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Omega Engineering DP3600?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Omega Engineering DP3600, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Omega Engineering DP3600 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)