    The W ireless Connectivity Expert 4851 1 W arm Springs Blvd., Suite 206, Fr emont CA 94539 Te l : +1-510-490-8024 F a x : +1-510-623-7268 We b s i t e : http://www .actisys.com/ E-mail: irda-info@actisys.com ACT -IR100SD OBEX Server IrReady Intelligent Adapter User ’ s Manual October 30, 2006 V er . 1.0 © Copyright 2000-2006 ACTiSYS Corporation ...

  • ACTiSYS ACT-IR100SD - page 2

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 7. ACT -IR100SD DONGLE DIMENSIONS .............................................................. 17 V ersion 1.0 T ABLE OF CONTENTS REVISION H ISTOR Y ............................................................................................... 3 PRECAUTIONS ............ ...

  • ACTiSYS ACT-IR100SD - page 3

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual REVISION HIST OR Y Revision History Revision Date Comment 1.0 10/30/2006 Draft Preliminary Design S pecification.  Copyright 2000-2006 ACT iSYS Corp. Page 3 of 17 Oct 30, 2006 V ersion 1.0 ...

  • ACTiSYS ACT-IR100SD - page 4

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual PRECAUTIONS T o ensure trouble-free operation, please observe the following precautions: Optical communications are easily affected by exte rnal light sources, weak batteries, transfer distance, transfer angle, etc. Any of these conditions may cause a data transfer failure ...

  • ACTiSYS ACT-IR100SD - page 5

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 1. FEA TURES  A complete IrDA Protocol stack in a dongle.  Supports both IrDA Primary and Secondary mode, changeable via PC utility .  No driver program is needed.  Supports mandatory IrDA layer: IrPHY , IrLAP , IrLMP and IAS.  Supports upper layers T inyTP ...

  • ACTiSYS ACT-IR100SD - page 6

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 2. OVERVIEW The ACT -IR100SD is a high-integration IrDA Intelligent dongle. It provides a seria l interface to a host device that intends to have Infrared communication capability . The host device can be any equipment or device that needs to communicate with IrDA enabled ...

  • ACTiSYS ACT-IR100SD - page 7

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 3. ARCHITECTURE OF ACT -IR100SD The mandatory IrDA protocol layers, IrLAP and IrLMP (including IAS) are handled by ACT -I R100SD, In addition, T i nyTP , IrCOMM, IrLPT and OBEX transport are also included. The incoming/outgoing IrDA user data p ayload are buffered and then ...

  • ACTiSYS ACT-IR100SD - page 8

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual  Copyright 2000-2006 ACT iSYS Corp. Page 8 of 17 Oct 30, 2006 4. HOST INTERF ACE The host interface of ACT -IR100SD is a full-duplex asynchronous RS232 DB9M connector . The following table is the signals of D B9M connector . It can be treated as DTE. The data bytes are ...

  • ACTiSYS ACT-IR100SD - page 9

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 4.1 Host Interface Signals ACT -IR100SD host interface consists of three output signals and five input signals. All these signals are low active. That is, they are at 0V when active and at VCC level when inactive. When an inverting RS232 level converter is used, the corres ...

  • ACTiSYS ACT-IR100SD - page 10

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual  Copyright 2000-2006 ACT iSYS Corp. Page 10 of 17 Oct 30, 2006 V ersion 1.0 5. OPERA TING IN ACT -IR100SD 5.1 How T o Connect IR100SD With Host Device: IR100SD uses a standard RS232 DTE port to connect with the host. If the host device is a Modem like device and has a R ...

  • ACTiSYS ACT-IR100SD - page 11

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 5.2.1 The first page is to set the host baud rate and the hardware flow control. Please Note: Ignore CTS: If host device has no hardware flow control signals, only Tx, Rx and GND, then you have to set this bit to 1. IR100SD will pass the coming dat a to host and doesn’t ...

  • ACTiSYS ACT-IR100SD - page 12

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 5.2.2 The second page is to set time interval of discovery , the slot number of discovery and the mode of IR100SD. 1) IR100SD supports both Primary and Secondary . It allows customer to change it. 2) Discovery time should be 3 seconds in general. If you want the discovery ...

  • ACTiSYS ACT-IR100SD - page 13

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 5.2.3 The third page is to set the IrDA protocols when IR100SD is in Primary .  Copyright 2000-2006 ACT iSYS Corp. Page 13 of 17 Oct 30, 2006 V ersion 1.0 ...

  • ACTiSYS ACT-IR100SD - page 14

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 5.3 OBEX PUT/GET Description The OBEX specification consist s of two major part s: a protocol and an application framework. This is also illustrated graphically below . The "application framework" is represented in ellipses inside the "wide word of applicati ...

  • ACTiSYS ACT-IR100SD - page 15

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual The following figure shows how cellphone or PDA delivers an object (maybe a phone book record, a picture or a formatted data) to user’s host. W hen IR100SD-OBEX-Server receives OBEX PUT command, it will act like a PUT ser ver and reply proper response. Then it will trim ...

  • ACTiSYS ACT-IR100SD - page 16

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual Frame length means total frame size, including byte 0,1, 2, and 3. For example, if dat a frame is 300 bytes, length should be 304. 6. THE DEF AUL T SETTING OF ACT -IR100SD The default setting of ACT -IR100SD is configured as the following: Parameters Setting Host baud rate ...

  • ACTiSYS ACT-IR100SD - page 17

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual  Copyright 2000-2006 ACT iSYS Corp. Page 17 of 17 Oct 30, 2006 7. ACT -IR100SD DONGLE DIMENSIONS 8. CHARACTERISTICS AND SPECIFICA TION Parameter Min. T ypical Max. Unit s DC supply v oltage 6.0 7.5 12 V Supply v oltage, VSS 0 V Operating temperature range, TA 0 60 ℃ D ...

Fabricante ACTiSYS Categoría Network Card

Los documentos del dispositivo ACTiSYS ACT-IR100SD que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos ACTiSYS
- manuales de instrucciones ACT-IR100SD
- hojas de producto ACTiSYS
- folletos informativos
- o etiquetas energéticas ACTiSYS ACT-IR100SD
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones ACTiSYS ACT-IR100SD.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje ACTiSYS ACT-IR100SD, instrucciones de servicio, instrucciones cortas o instrucciones de usuario ACTiSYS ACT-IR100SD. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto ACTiSYS ACT-IR100SD.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo ACTiSYS ACT-IR100SD, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar ACTiSYS ACT-IR100SD. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de ACTiSYS ACT-IR100SD.

El manual de instrucciones completo de ACTiSYS debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual ACTiSYS ACT-IR100SD - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice ACTiSYS ACT-IR100SD, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de ACTiSYS ACT-IR100SD que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo ACTiSYS ACT-IR100SD - que deben facilitarnos los primeros pasos durante el uso de ACTiSYS ACT-IR100SD
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con ACTiSYS ACT-IR100SD
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de ACTiSYS ACT-IR100SD en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de ACTiSYS ACT-IR100SD?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con ACTiSYS ACT-IR100SD, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con ACTiSYS ACT-IR100SD probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)