Manual ACTiSYS ACT-IR100SD

17 pages 0.71 mb
Download

Go to site of 17

Summary
  • ACTiSYS ACT-IR100SD - page 1

    The W ireless Connectivity Expert 4851 1 W arm Springs Blvd., Suite 206, Fr emont CA 94539 Te l : +1-510-490-8024 F a x : +1-510-623-7268 We b s i t e : http://www .actisys.com/ E-mail: irda-info@actisys.com ACT -IR100SD OBEX Server IrReady Intelligent Adapter User ’ s Manual October 30, 2006 V er . 1.0 © Copyright 2000-2006 ACTiSYS Corporation ...

  • ACTiSYS ACT-IR100SD - page 2

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 7. ACT -IR100SD DONGLE DIMENSIONS .............................................................. 17 V ersion 1.0 T ABLE OF CONTENTS REVISION H ISTOR Y ............................................................................................... 3 PRECAUTIONS ............ ...

  • ACTiSYS ACT-IR100SD - page 3

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual REVISION HIST OR Y Revision History Revision Date Comment 1.0 10/30/2006 Draft Preliminary Design S pecification.  Copyright 2000-2006 ACT iSYS Corp. Page 3 of 17 Oct 30, 2006 V ersion 1.0 ...

  • ACTiSYS ACT-IR100SD - page 4

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual PRECAUTIONS T o ensure trouble-free operation, please observe the following precautions: Optical communications are easily affected by exte rnal light sources, weak batteries, transfer distance, transfer angle, etc. Any of these conditions may cause a data transfer failure ...

  • ACTiSYS ACT-IR100SD - page 5

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 1. FEA TURES  A complete IrDA Protocol stack in a dongle.  Supports both IrDA Primary and Secondary mode, changeable via PC utility .  No driver program is needed.  Supports mandatory IrDA layer: IrPHY , IrLAP , IrLMP and IAS.  Supports upper layers T inyTP ...

  • ACTiSYS ACT-IR100SD - page 6

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 2. OVERVIEW The ACT -IR100SD is a high-integration IrDA Intelligent dongle. It provides a seria l interface to a host device that intends to have Infrared communication capability . The host device can be any equipment or device that needs to communicate with IrDA enabled ...

  • ACTiSYS ACT-IR100SD - page 7

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 3. ARCHITECTURE OF ACT -IR100SD The mandatory IrDA protocol layers, IrLAP and IrLMP (including IAS) are handled by ACT -I R100SD, In addition, T i nyTP , IrCOMM, IrLPT and OBEX transport are also included. The incoming/outgoing IrDA user data p ayload are buffered and then ...

  • ACTiSYS ACT-IR100SD - page 8

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual  Copyright 2000-2006 ACT iSYS Corp. Page 8 of 17 Oct 30, 2006 4. HOST INTERF ACE The host interface of ACT -IR100SD is a full-duplex asynchronous RS232 DB9M connector . The following table is the signals of D B9M connector . It can be treated as DTE. The data bytes are ...

  • ACTiSYS ACT-IR100SD - page 9

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 4.1 Host Interface Signals ACT -IR100SD host interface consists of three output signals and five input signals. All these signals are low active. That is, they are at 0V when active and at VCC level when inactive. When an inverting RS232 level converter is used, the corres ...

  • ACTiSYS ACT-IR100SD - page 10

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual  Copyright 2000-2006 ACT iSYS Corp. Page 10 of 17 Oct 30, 2006 V ersion 1.0 5. OPERA TING IN ACT -IR100SD 5.1 How T o Connect IR100SD With Host Device: IR100SD uses a standard RS232 DTE port to connect with the host. If the host device is a Modem like device and has a R ...

  • ACTiSYS ACT-IR100SD - page 11

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 5.2.1 The first page is to set the host baud rate and the hardware flow control. Please Note: Ignore CTS: If host device has no hardware flow control signals, only Tx, Rx and GND, then you have to set this bit to 1. IR100SD will pass the coming dat a to host and doesn’t ...

  • ACTiSYS ACT-IR100SD - page 12

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 5.2.2 The second page is to set time interval of discovery , the slot number of discovery and the mode of IR100SD. 1) IR100SD supports both Primary and Secondary . It allows customer to change it. 2) Discovery time should be 3 seconds in general. If you want the discovery ...

  • ACTiSYS ACT-IR100SD - page 13

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 5.2.3 The third page is to set the IrDA protocols when IR100SD is in Primary .  Copyright 2000-2006 ACT iSYS Corp. Page 13 of 17 Oct 30, 2006 V ersion 1.0 ...

  • ACTiSYS ACT-IR100SD - page 14

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 5.3 OBEX PUT/GET Description The OBEX specification consist s of two major part s: a protocol and an application framework. This is also illustrated graphically below . The "application framework" is represented in ellipses inside the "wide word of applicati ...

  • ACTiSYS ACT-IR100SD - page 15

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual The following figure shows how cellphone or PDA delivers an object (maybe a phone book record, a picture or a formatted data) to user’s host. W hen IR100SD-OBEX-Server receives OBEX PUT command, it will act like a PUT ser ver and reply proper response. Then it will trim ...

  • ACTiSYS ACT-IR100SD - page 16

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual Frame length means total frame size, including byte 0,1, 2, and 3. For example, if dat a frame is 300 bytes, length should be 304. 6. THE DEF AUL T SETTING OF ACT -IR100SD The default setting of ACT -IR100SD is configured as the following: Parameters Setting Host baud rate ...

  • ACTiSYS ACT-IR100SD - page 17

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual  Copyright 2000-2006 ACT iSYS Corp. Page 17 of 17 Oct 30, 2006 7. ACT -IR100SD DONGLE DIMENSIONS 8. CHARACTERISTICS AND SPECIFICA TION Parameter Min. T ypical Max. Unit s DC supply v oltage 6.0 7.5 12 V Supply v oltage, VSS 0 V Operating temperature range, TA 0 60 ℃ D ...

Manufacturer ACTiSYS Category Network Card

Documents that we receive from a manufacturer of a ACTiSYS ACT-IR100SD can be divided into several groups. They are, among others:
- ACTiSYS technical drawings
- ACT-IR100SD manuals
- ACTiSYS product data sheets
- information booklets
- or energy labels ACTiSYS ACT-IR100SD
All of them are important, but the most important information from the point of view of use of the device are in the user manual ACTiSYS ACT-IR100SD.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals ACTiSYS ACT-IR100SD, service manual, brief instructions and user manuals ACTiSYS ACT-IR100SD. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product ACTiSYS ACT-IR100SD.

A complete manual for the device ACTiSYS ACT-IR100SD, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use ACTiSYS ACT-IR100SD by users. Manuals are usually written by a technical writer, but in a language understandable to all users of ACTiSYS ACT-IR100SD.

A complete ACTiSYS manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual ACTiSYS ACT-IR100SD - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the ACTiSYS ACT-IR100SD, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the ACTiSYS ACT-IR100SD, that we can find in the current document
3. Tips how to use the basic functions of the device ACTiSYS ACT-IR100SD - which should help us in our first steps of using ACTiSYS ACT-IR100SD
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with ACTiSYS ACT-IR100SD
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of ACTiSYS ACT-IR100SD in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning ACTiSYS ACT-IR100SD?

Use the form below

If you did not solve your problem by using a manual ACTiSYS ACT-IR100SD, ask a question using the form below. If a user had a similar problem with ACTiSYS ACT-IR100SD it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)