    SS-CPH90-150 ww w .goodmanmfg.c om 6/11 Supersedes 3/11 Standard Featur es • R-410Achlorine -freerefrigerant • High- eciencyscrollcompressor • Coppertube/aluminumncoils • Contactorwithlugs • High- capacity,st eel- casedlterdryer • Single -pointentry • 24-volt? ...

  • Goodman Mfg SS-CPH90-150 - page 2

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCa tionS 2 ww w .goodmanmfg.c om SS-CPH90-150 n omenCla ture  C P H 090 045 3 B X X X           Brand F actoryInstalledOp<ons      ? ...

  • Goodman Mfg SS-CPH90-150 - page 3

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCa tionS SS-CPH90-150 ww w .goodmanmfg.c om 3 P roduCt S PeCifiCa tionS — 7½ t onS CPH090 ***3B*** CPH090 ***4B*** CPH090 ***7B*** Cooling Cap a city T otal BTU/h 90,000 90,000 90,000 Sensible BTU/h 65,700 65,700 65,700 EER / IEER 11.5 / 11.2 11.5 / 11.2 11.5 / 11.2 IPL V 12.30 12.30 12.30 Decibels 83 8 ...

  • Goodman Mfg SS-CPH90-150 - page 4

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 4 ww w .goodmanmfg.c om SS-CPH90-150 P roduCt S PeCifiCa tionS — 8½ t onS CPH102 ***3B*** CPH102 ***4B*** CPH102 ***7B*** Cooling Cap acity T otal, BTU/h 102,000 102,000 102,000 Sensible BTU/h 73,440 73,440 73,440 EER / IEER 11.1 / 11.2 11.1 / 11.2 11.1 / 11.2 Decibels 83 83 83 ARI Ref erence #s ...

  • Goodman Mfg SS-CPH90-150 - page 5

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 5 P roduCt S PeCifiCa tionS — 1 0 t onS CPH120 ***3B*** CPH120 ***4B*** CPH120 ***7B*** Cooling Cap acity T otal BTU/h 118,000 118,000 118,000 Sensible BTU/h 87,300 87,300 87,300 EER / IEER 11.5 / 11.5 11.5 / 11.5 11.5 / 11.5 Decibels 83 83 83 Hea ting Cap acity ...

  • Goodman Mfg SS-CPH90-150 - page 6

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 6 ww w .goodmanmfg.c om SS-CPH90-150 P roduCt S PeCifiCa tionS — 12½ t onS CPH150XXX 3BXXX CPH150XXX 4BXXX CPH150XXX 7BXXX Cooling Cap acity T otal, BTU/h 146,000 146,000 146,000 Sensible BTU/h 102,200 102,200 102,200 EER / IPL V 10.8 / 11.2 10.8 / 11.2 10.8 / 11.2 Decibels 83 83 83 ARI Ref eren ...

  • Goodman Mfg SS-CPH90-150 - page 7

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 7 e xP anded H eating d a ta CPH090 Outdoor Ambient Temper a ture 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 114.4 108.3 101.9 95.3 91.0 88.2 81.9 75.5 70.5 65.0 59.9 56.6 54.5 48.9 43.3 37.8 32.2 26.4 T/ R 35.3 33.4 31.5 29.4 28.1 27.2 25.3 23.3 21. ...

  • Goodman Mfg SS-CPH90-150 - page 8

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 8 ww w .goodmanmfg.c om SS-CPH90-150 e xP anded C ooling d at a — 7½ t onS Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 3375 MBh 88.2 91.4 100.2 - 86.1 89.3 97.8 - 8 ...

  • Goodman Mfg SS-CPH90-150 - page 9

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 9 e xP anded C ooling d at a — 7½ t onS ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 3375 MBh 91.3 93.3 99.7 106.5 89.2 ...

  • Goodman Mfg SS-CPH90-150 - page 10

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 10 ww w .goodmanmfg.c om SS-CPH90-150 e xP anded C ooling d at a — 8½ t onS Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 3820 MBh 100.0 103.6 113.5 - 97.6 101.2 110. ...

  • Goodman Mfg SS-CPH90-150 - page 11

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 11 e xP anded C ooling d at a — 8½ t onS ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 3820 MBh 103.5 105.7 112.9 120.7 1 ...

  • Goodman Mfg SS-CPH90-150 - page 12

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 12 ww w .goodmanmfg.c om SS-CPH90-150 e xP anded C ooling d at a — 1 0 t onS Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 4500 MBh 115.6 119.8 131.3 - 112.9 117.1 128 ...

  • Goodman Mfg SS-CPH90-150 - page 13

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 13 e xP anded C ooling d at a — 1 0 t onS ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 4500 MBh 119.7 122.3 130.7 139.7 1 ...

  • Goodman Mfg SS-CPH90-150 - page 14

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 14 ww w .goodmanmfg.c om SS-CPH90-150 e xP anded C ooling d at a — 12½ t onS Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 4725 MBh 143.1 148.3 162.5 - 139.7 144.8 15 ...

  • Goodman Mfg SS-CPH90-150 - page 15

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 15 e xP anded C ooling d at a — 12½ t onS ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 4725 MBh 148.1 151.3 161.7 172.8 ...

  • Goodman Mfg SS-CPH90-150 - page 16

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 16 ww w .goodmanmfg.c om SS-CPH90-150 a irfl ow d a ta — 7½ t onS St andard Bel t Drive — Down Sho t ESP , In H 2 O T urns Open 012345 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0.1 3617 704 1.07 3293 653 0.84 0.3 3541 749 1.15 3179 704 0.88 2757 656 0.66 0.5 3447 ...

  • Goodman Mfg SS-CPH90-150 - page 17

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 17 a irfl ow d a ta — 8½ t onS St andard Bel t Drive — Down Sho t ESP , In H 2 O T urns Open 012345 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0.1 3467 701 1.04 3143 650 0.81 0.3 3391 746 1.12 3029 701 0.85 2607 653 0.63 0.5 3297 ...

  • Goodman Mfg SS-CPH90-150 - page 18

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 18 ww w .goodmanmfg.c om SS-CPH90-150 a irfl ow d a ta — 1 0 t onS St andard Bel t Drive — Down sho t ESP , In H 2 O T urns Open 012345 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0.2 4629 774 1.76 4269 733 1.42 0.4 4539 824 1.86 4198 781 1.53 3797 735 1.21 0.6 4511 ...

  • Goodman Mfg SS-CPH90-150 - page 19

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 19 a irfl ow d a ta — 12½ t onS St andard Bel t Drive --- Down Sho t ESP (in W .C.) T urns Open 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0.2 5378 2.35 4967 1.92 4710 1.59 4512 1.33 0.4 5514 2.92 5349 2.56 4750 1.97 4583 1.71 4319 1.40 4030 1. ...

  • Goodman Mfg SS-CPH90-150 - page 20

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 20 ww w .goodmanmfg.c om SS-CPH90-150 H ea t k it e leCtriCal d a t a — 7½ t onS m inimum a irflow for e leCtriC H ea t Hea ter Size (kW) Minimum CFM 15 3,000 30 3,000 43 3,000 kW Correction F actor f or 3-Phase Units Suppl y Vol t age 240 230 220 210 208 Correction F actor 1 0.93 0.82 0.78 0.76 ...

  • Goodman Mfg SS-CPH90-150 - page 21

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 21 H ea t k it e leCtriCal d a t a — 8½ t onS Model and Hea t Kit Usage MCA¹ a t 240V MOP² (amps) a t 240V Actu al kW a t 240V Recommended Airflow Range (Downsho t) Recommended Airflow Range (Horizont al) CPH102***3B*** 43 50 EHK3-16 88 90 15 3400 - 3825 CFM ...

  • Goodman Mfg SS-CPH90-150 - page 22

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 22 ww w .goodmanmfg.c om SS-CPH90-150 H ea t k it e leCtriCal d a t a — 1 0 t onS k w C orreCtion f aCt or kW Corre ction Fa ctor (for 1- & 3-Pha se Units) Supply V oltage 240 230 220 210 208 Correcon F actor 1 0.93 0.82 0.78 0.76 kW Corre ction Fa ctor for 480V Unit s Actual V oltage 460 ...

  • Goodman Mfg SS-CPH90-150 - page 23

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 23 H ea t k it e leCtriCal d a t a — 12½ t onS kW Corre ction Fa ctor for 1- & 3-Pha se Units Suppl y V ol t age 240 230 220 210 208 Corre ction Fa ctor 1 0.93 0.82 0.78 0.76 kW Corre ction Fa ctor for 480V Unit s Suppl y V ol t age 460 440 430 Corre ction ...

  • Goodman Mfg SS-CPH90-150 - page 24

    P roduct S Pecifica tionS P roduct S PecificationS 24 ww w .goodmanmfg.c om SS-CPH90-150 d imenSionS 20 APPENDIX C UNIT DIMENSIONS Horizontal Discharge Vertical Discharge (Bottom of Unit) RETURN SUPPL Y 13 7/ 8” 28 3/ 8” 7 3/8” 12 5/ 8” 6 1/4 ” 36 3/ 8” 5 7/8 ” RETURN SUP PL Y 5 3/8” 7 1/2” 6 1/2” 99 1/ 8” 61 3/ 4” Y NOTE Fo ...

  • Goodman Mfg SS-CPH90-150 - page 25

    P roduct S Pecifica tionS P roduct S PecificationS SS-CPH90-150 ww w .goodmanmfg.c om 25 48” 36” Min. 48” 48” 75” u nit c learanceS e lectrical e ntrance l oca tionS 11⅝” 10 3 / 16 ” 3” Low -V oltage Entr ance High-V oltage En trance Dimples Mark Drill Locaons Maintain an adequate clearance around the unit for saf ety, service, ...

  • Goodman Mfg SS-CPH90-150 - page 26

    P roduct S Pecifica tionS P roduct S PecificationS 26 ww w .goodmanmfg.c om SS-CPH90-150 r oof c urb i nSt alla tion — r igging Pr ovisions for forks hav e been included in the unit base frame. No other fork locations are appr oved. • Unit must be lifted by the four lifting holes located at the base frame corners. • Lifting cables shoul ...

  • Goodman Mfg SS-CPH90-150 - page 27

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 27 r oof C urB i nSt alla tion ( Cont .) Curb installations must comply with local codes and should follow the establishedguidelinesoftheNationalRoongContractorsAssociation. Pr operunit installation ...

  • Goodman Mfg SS-CPH90-150 - page 28

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 28 ww w .goodmanmfg.c om SS-CPH90-150 w iring d ia gram — CPH090- 120***3B/ 4B ( for modelS witH Serial numBerS 090 7 and Below ) Wiring is subject to change. Alwa ys ref er to the wiring diagram or the unit for the most up-t o-date wiring. ⚠ W arning High Volt age:   ...

  • Goodman Mfg SS-CPH90-150 - page 29

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 29 w iring d ia gram — CPH090- 120***3B/ 4B ( Cont .) ( for modelS witH Serial numBerS 090 7 and Below ) Wiring is subject to change. Alwa ys ref er to the wiring diagram or the unit for the most up-t o-date wiring. ⚠ W arning High Volt age:  ? ...

  • Goodman Mfg SS-CPH90-150 - page 30

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 30 ww w .goodmanmfg.c om SS-CPH90-150 w iring d ia gram — CPH090- 120***3B/ 4B/ 7B*** TB1 OR BR REPLACE JUMP ER WI TH SMOKE/FIRE DETECTOR RD C 3 BL 1 PK 240 460 BL OR RD GR BK OR RD OR RD RD RD 6 GND COM HVDR R DFT1 L3 BK T3 YL NOTE 3 PLF NC NO BK UP RD GR BK 2 C WH C 8 L2 K1 BK BR DF2 C YL SPEED ...

  • Goodman Mfg SS-CPH90-150 - page 31

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 31 w iring d ia gram — CPH090- 120***3B/ 4B/ 7B*** ( Cont .) R EBTDR BC R HVDR Y RVC1 SEE UNIT RATING PLATE FOR TYPE AND SIZE 5 OF OVER CU RRENT PROTECTION 4 BLOW ER CONTACTOR COMPRESSOR CONTACTOR CONDENSER MOT OR CONDENSER M OTOR CONTACTOR COMPRESSOR DEFROST CO ...

  • Goodman Mfg SS-CPH90-150 - page 32

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 32 ww w .goodmanmfg.c om SS-CPH90-150 TB1 OR BR REPLACE JUMP ER WITH SMOKE/FIRE DE TECTOR RD C 3 BL 1 PK 240 460 BL OR RD GR BK OR RD OR RD RD RD 6 GND COM HVDR R DFT1 L3 BK T3 YL NOTE 3 PLF NC NO BK UP RD GR BK 2 C WH C 8 L2 K1 BK BR DF2 C YL SPEED R RVC1 DC BK RD YL L1 O 5 7 BL K1 BK M1 LPS2 XFMR ...

  • Goodman Mfg SS-CPH90-150 - page 33

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 33 w iring d ia gram — CPH1 50***3B/ 4B/ 7B*** ( Cont .) R EBTDR BC R HVDR Y RVC1 SEE UNIT RATING PLATE FOR TYPE AN D SIZE 5 OF OVER CUR RENT PROTECTION 4 BLOW ER CONTACTOR COMPRESSOR CO NTACTOR CONDENSER MOTOR CONDENSER MO T OR CONTACTOR COMPRESSOR DEFROST CONT ...

  • Goodman Mfg SS-CPH90-150 - page 34

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 34 ww w .goodmanmfg.c om SS-CPH90-150 a CCeSSorieS Item # Description Fits Model Sizes 14CURB90150 Roof Curb 14" T all 7½-12½ tons 25FD90150 25% Manual Fresh Air Damper 7½-12½ tons 25MFD90150 25% Motoriz ed Fresh Air Damper 7½-12½ tons BRD3672 Horizontal Bar ometric Relief Damper (two r ...

  • Goodman Mfg SS-CPH90-150 - page 35

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 35 n o teS ...

  • Goodman Mfg SS-CPH90-150 - page 36

    P roduct S Pecifica tionS P roduct S PecificationS 36 ww w .goodmanmfg.c om SS-CPH90-150 Goodman Manufacturing Company, L.P ., reser ves the right to discontinue, or change at an y time, specications or designs without noticeorwithoutincurringobligations.©2010•GoodmanManufacturingCompany,L.P .•? ...

Fabricante Goodman Mfg Categoría Air Conditioner

Los documentos del dispositivo Goodman Mfg SS-CPH90-150 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Goodman Mfg
- manuales de instrucciones SS-CPH90-150
- hojas de producto Goodman Mfg
- folletos informativos
- o etiquetas energéticas Goodman Mfg SS-CPH90-150
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Goodman Mfg SS-CPH90-150.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Goodman Mfg SS-CPH90-150, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Goodman Mfg SS-CPH90-150. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Goodman Mfg SS-CPH90-150.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Goodman Mfg SS-CPH90-150, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Goodman Mfg SS-CPH90-150. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Goodman Mfg SS-CPH90-150.

El manual de instrucciones completo de Goodman Mfg debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Goodman Mfg SS-CPH90-150 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Goodman Mfg SS-CPH90-150, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Goodman Mfg SS-CPH90-150 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Goodman Mfg SS-CPH90-150 - que deben facilitarnos los primeros pasos durante el uso de Goodman Mfg SS-CPH90-150
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Goodman Mfg SS-CPH90-150
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Goodman Mfg SS-CPH90-150 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Goodman Mfg SS-CPH90-150?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Goodman Mfg SS-CPH90-150, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Goodman Mfg SS-CPH90-150 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)