Manual de instrucciones Emerson GXT5000R-208

32 de páginas 0.45 mb
Descargar

Pasar a la página of 32

Summary
  • Emerson GXT5000R-208 - page 1

    P OWER A VAILABILITY GXT5000R-208 with GXT5VBA TTW120 / GXT5VBA TT Batter y Cabinets U SER M ANUAL 5000 V A / 3750 W 208 V olt ...

  • Emerson GXT5000R-208 - page 2

    ...

  • Emerson GXT5000R-208 - page 3

    i T ABLE OF CONTENTS I MPORT ANT S AFETY I NSTRUCTIO NS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 G LOSSARY OF S YMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 I NTRODUCTIO N AND S YST EM D ESCRIPTION . . . . . . . . . . . . . . . . . . . . . . ...

  • Emerson GXT5000R-208 - page 4

    ii UPS C OMMUNI CATIONS WITH I NTELLISLOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 M AINTENAN CE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 T ROUBLESHOOTIN G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Emerson GXT5000R-208 - page 5

    1 IMPORT ANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual co ntains important safe ty instructions. R ead all safety, in stallation, and o perat- ing instructions before operati ng the Uninterruptible Power System (UPS). Ad here to all warnings on th e unit and in this manua l. Follow all o perating and u ser instructions. Individ- uals ...

  • Emerson GXT5000R-208 - page 6

    2 SERVICE PERSONNEL INFORMA TION Servicing of batteri es should be performed by qualified p ersonnel knowle dgeable about ba tter- ies and the required precautio ns. Keep unaut horized personnel away from the batteries. PROPER DISPOSAL OF BATTERIES IS RE QUIRED. REFER TO YOUR LOCAL LAW S AND REGULATIONS FOR BATTERY DISPOSAL REQUIREMENTS. When repla ...

  • Emerson GXT5000R-208 - page 7

    3 GLOSSARY OF SYMBOLS • Risk of ele ctrical shock Indicates caution followed by important instructions Requests the user to consult the manual Indicates the unit contains a valve-regulated lead acid batter y Recycle DC voltage Equipment grounding conductor Bonded to ground AC voltage ON Standby i ...

  • Emerson GXT5000R-208 - page 8

    4 INTRODUCTION AND SYSTEM DESCRIPTION Congratulations on your choice of the Liebert GXT5 000R-208 U ninterruptible Pow er System (UPS). It provides conditioned power to microco mputers and other sensitiv e electronic equip- ment. Upon generation, AC power is cl ean and stable. However, during transmission and distribu- tion it may be subject to vol ...

  • Emerson GXT5000R-208 - page 9

    5 MAJOR COMPONENT S T ransient V olt age Surge Suppress ion (TVSS) & EMI/RFI Filters These UPS components provide surge protection and filter both elect romagnetic interference (EMI) and radio frequency interferen ce (RFI). They minimize any surg es or interference present in the ut ility line and k eep sensitive equipment protected. Rectifier/ ...

  • Emerson GXT5000R-208 - page 10

    6 Auxiliary 120 V / 400 V A Power The GXT5VBATTW120 battery cabinet also provides a tran sformer to provide up to 400 VA of 120 V power. Dynamic Byp ass The GXT5000R-208 provides a n alternate path fo r util ity power to the connected load in the unlikely event of a U PS malfuncti on, such as overload, ove rtemp erature, or an internal UPS failure. ...

  • Emerson GXT5000R-208 - page 11

    7 GENERAL DESCRIPTION Figure 1 GXT5000R-208 UPS - Front view Figure 2 GXT5000R-208 UPS - Rear view Air vents Control panel 20 A AC output with circuit breaker L6-20R Input cord L6-30P 30 A inpu t circuit breaker RELA YCARD-INT alarm contact s EPO DB-9 connector No user connection Cooling fans 30 A AC output L6-30R 208 V AC power to auxiliary power ...

  • Emerson GXT5000R-208 - page 12

    8 Figure 3 GXT5VBA TTW120 battery cabinet with auxiliary 120 V AC power - Rear view Figure 4 GXT5VBA TT batt ery cabinet - Rear view 208 V AC power from rear of GXT5000R-208 to auxiliar y power input connec tor (see Figure 2) DC cable from rear of GXT5000R-208 to external battery cabin et (see Figure 2) External battery connectors Auxiliary power 1 ...

  • Emerson GXT5000R-208 - page 13

    9 GENERAL INST ALLATION 1. Verify that the 30 A input circuit breaker on the GXT5000R-208 is in the OFF position. 2. For GXT5VBATTW120 only - C onnect the 208 V , one-foot-lon g cord, from the rear of the GXT5000R-208 to the mating external battery connector on the rear of the GXT5VBATTW120. 3. Connect the L6-20P from the load to the L6-20R on the ...

  • Emerson GXT5000R-208 - page 14

    10 CONTROLS AND INDICATORS ON / Manual Battery T e st button This button controls output power to connected load(s) and has two functions: • Transfer load to inverter • Manual battery test Pressing the ON / Manual Battery Test button will transfer the load from bypass to inverter in order to provide conditioned and protected power to the output ...

  • Emerson GXT5000R-208 - page 15

    11 Load Level indicators - 4 green, 1 amber , 1 red LEDs The Load Level indicators display the approximate load level at all times. • The four green LEDs indicate acceptable levels up to 95%. • The amber light comes on when the load level is 96-105%. • The last LED at right (red) indicates an overload (more than 105%) and warns of immi- nent ...

  • Emerson GXT5000R-208 - page 16

    12 MODES OF OPERATION Normal Mode Operation During normal operation, utility power provid es energy to the UPS. The filters, the power fac- tor correction circuit and the inverter process th is power to provide computer-grade pow er to connected loads. The UPS maintains the batteries in a fully charged sta te. Battery Mode Operation The UPS will en ...

  • Emerson GXT5000R-208 - page 17

    13 Byp ass Mode Bypass mode provides an alternate path for util ity power to the connecte d load in the unlikely event of a UPS malfunctio n, such as overload, ove rtemperat ure, or an internal UPS failure. Battery Recharge Mode Once utility power is restored, the UPS resu mes normal operation and the Battery Charger begins recharging the battery. ...

  • Emerson GXT5000R-208 - page 18

    14 OPERATING INSTRUCTIONS Tu r n O n Once the AC supply has been applied to the unit, power will be applied to the load ( bypass mode) immedia tely when the 30 A input circuit breaker i s initially cl osed. Turn the u nit ON (inverter mode) by pressing the ON button once. Manual Byp ass To manually put the unit in Bypass mode, press the Stand b y b ...

  • Emerson GXT5000R-208 - page 19

    15 OPTIONAL BATTERIES - PROGRAMMABLE RUN T IME The GXT5000R-208 may be equipp ed with up to five battery GXT5VBATT cabinets. At least one battery cabinet is required. The first bat tery cabinet may be a GXT5VBATTW120 if a 120V, 400V A auxiliary vo ltage source is nee ded. The enhanced communication provides an estima ted run time in minutes , takin ...

  • Emerson GXT5000R-208 - page 20

    16 Procedure to confirm the battery count 1. Apply AC inpu t power to the U PS. 2. Turn the UPS output off using the Standby bu tton. If the U PS is in inverter mod e, the load must first be transferred to bypass and then to off. 3. Once the UPS output is off, press and ho ld the Standby button continuously. The Sta ndby button must be held continu ...

  • Emerson GXT5000R-208 - page 21

    17 COMMUNICATIONS Do not exceed NEC Class 2 limits for any co nnection to the DB-25 connector on the Relay Interface card, the DB-9 communication port, and the EPO connector. Relay Interface Card Your GXT5000R-208 comes equi pped with the RELAYCARD-INT relay card. Connections must not exceed NEC Class 2 limits. The Intellislot ® Interface for Rela ...

  • Emerson GXT5000R-208 - page 22

    18 EPO This unit is equipped with provisions for the terminal connections for a UPS Emergency Power OFF Switch (EPO). The term inal is located on the rear of the UPS next to the DB-9 connector. If an EPO switch is used, it must have the characteristic s of an emergency but- ton—closed under normal conditions and held op en mechanically when opera ...

  • Emerson GXT5000R-208 - page 23

    19 SERIAL COMMUNICATIONS The UPStationGXT5000R-208 has a DB- 9 serial port male connector on the rear of the unit. Contact closure signals are not provided on this connector. Serial signals are provided on this port and are assigned as follows: This port is not directly compatible with th e Liebert M3LS9 P9S seri al communication cable supplied wit ...

  • Emerson GXT5000R-208 - page 24

    20 UPS COMMUNICATIONS WITH INTELLISLOT Your GXT5000R-208 come s equipped with the RELAYCAR D-IN T relay card. The addition of serial communi cations now ex pands the list of cards that may be used in the Intellislot. The UPStation GXT5000R-208 UPS is equipped wi th an Intellislot bay to provide advanced communication and mo nitoring op tions. Liebe ...

  • Emerson GXT5000R-208 - page 25

    21 MAINTENANCE The GXT5000R-208 UPS requires very little main tenance. The batteries are valve-regulated, nonspillab le, lead acid a nd should be kept charge d to obtain th eir design life . The UPS contin - uously charges the batteries when connected to the utility supply. When storing the UP S for an exte nded period, connect it to util ity power ...

  • Emerson GXT5000R-208 - page 26

    22 T ROUBLESHOOTING This section presents vario us problems a user mig ht encounter. Use this in formation to deter- mine whether external factors cause the problem an d how to remedy the situation. 1. The Fault LED will illuminate, in di cating the UPS detected a problem. 2. An alarm will sound , alerting that the UPS requires attention. 3. One or ...

  • Emerson GXT5000R-208 - page 27

    23 T able 3 T roubleshooting guide Fault classification LED display Audible alarm Condition Response time Bus fault C & F LEDs Continuous ± Bus V > 450 VDC 80 ms ± Bus V > 41 0 VDC 1.5 seconds ± Bus V < 230 VDC 80 ms |(Abnormal + Bus V)-(|-Bus V |)| > 40 VDC or |(+Bus V)-(Abnormal |-Bus V|)| > 35 VDC 2 minutes Inverter fault B ...

  • Emerson GXT5000R-208 - page 28

    24 S PECIFICATIONS MODEL NUMBER GXT5000R-208 MODEL RATING VA/W 5000 / 3750 DIMENSIONS: inches (mm) Unit: W x D x H 16.1 x 23.6 x 5.1(410 x 600 x 130) Shipping: W x D x H 23.2 x 31.1 x 12.8 (590 x 790 x 325) WEIGHT: lbs (kg) Unit 41.2 (18.7) Shipping 53.8 (24.4) INPUT AC PARAMETERS Voltage Range 208 VAC Nominal: 176-276 VAC Frequency 50/60 Hz, ±5%; ...

  • Emerson GXT5000R-208 - page 29

    25 BATTERY CABINET S PECIFICATIONS GXT5VBA TTW120 MODEL NUMBER GXT5VBATTW120 DIMENSIONS: inches (mm) Unit: W x D x H 16.1 x 23.6 x 5.1 (410 x 600 x 130) Shipping: W x D x H 23.2 x 31.1 x 12.8 (590 x 790 x 325) WEIGHT: lbs (kg) Unit 121.7 (55. 2) Shipping 132.3 (60.0) AC PARAMETER S – AUXILIARY AC POWER Nominal AC Input 208 VAC, 50/60 Hz, 400 VA, ...

  • Emerson GXT5000R-208 - page 30

    26 ...

  • Emerson GXT5000R-208 - page 31

    ...

  • Emerson GXT5000R-208 - page 32

    The Comp any Behind the Products With over a million installations around th e globe, Liebert is the world leader in computer protection systems. Since its founding in 1965, Liebert has developed a complete range of support and protection systems fo r sensitive electronics: • Environmental systems —Close-control air conditioning from 1 to 60 to ...

Fabricante Emerson Categoría Power Supply

Los documentos del dispositivo Emerson GXT5000R-208 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Emerson
- manuales de instrucciones GXT5000R-208
- hojas de producto Emerson
- folletos informativos
- o etiquetas energéticas Emerson GXT5000R-208
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Emerson GXT5000R-208.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Emerson GXT5000R-208, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Emerson GXT5000R-208. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Emerson GXT5000R-208.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Emerson GXT5000R-208, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Emerson GXT5000R-208. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Emerson GXT5000R-208.

El manual de instrucciones completo de Emerson debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Emerson GXT5000R-208 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Emerson GXT5000R-208, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Emerson GXT5000R-208 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Emerson GXT5000R-208 - que deben facilitarnos los primeros pasos durante el uso de Emerson GXT5000R-208
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Emerson GXT5000R-208
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Emerson GXT5000R-208 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Emerson GXT5000R-208?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Emerson GXT5000R-208, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Emerson GXT5000R-208 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)