    RT6621031r2 November 2013 This manual is to be used by qualified, professionally trained HV AC technicians only . Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures performed by an unqualified person. • Refer to Service Manual RS6612006 for troubleshooting information. • Refer to ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 2

    PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WA RNI N G WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Fail ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 3

    3 PRODUCT IDENTIFICA TION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GMS80403A*BB GMS80603A*BB GMS80604B*BB GMS80804B*BB GMS80805C*BB GMS81005C*BB GMS81205D*BA The United States Environmental Protection Agenc ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 4

    4 PRODUCT DESIGN NFPA 54/ANSI Z223.1 - latest edition. In Canada, the fur- naces must be vented in accordance with the National Stan- dard of Canada, CAN/CSA B149.1 and CAN/CSA B149.2 - latest editions and amendments. NOTE: The vertical height of the Category I venting system must be at least as great as the horizontal length of the venting system. ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 5

    5 COMPONENT IDENTIFICA TION Upflow/Horizontal 1 Tubular Heat Exchanger 2 Pressure Switch 3 Flue Pipe Connection 4 Induced Draft Blower 5 Gas Line Entrance 6 Gas Valve 7 Rollout Limit 8 Junction Box ? Pressur e Sw itch Tubul ar Heat E xchan g er Fl ue P i pe Co nn e c tion Ga s Li ne E nt ra nce (Alt e rnat e ) Ind uced Dr aft Blow er Ga s Li ne Ent ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 6

    PRODUCT DIMENSIONS 6 GMS8 A lt. Ga s Inlet H i g h Vol t ag e In le t L o w V oltage A lt. Ga s Inlet A lt. High V o lt ag e Alt. LowV oltage MOD E L A B G M S 8 04 03 A ** * G M S 8 06 03 A ** * G M S 8 06 04 B * ** G M S 8 08 04 B * ** G M S 8 08 05 C * ** G M S 8 10 05 C * ** G M S 8 12 05 D * ** G M S814 05D N ** 24 - 1/ 2 23 21 19 - 1/ 2 14 12 ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 7

    7 PRODUCT DIMENSIONS GMS8[040-100]BB GMS81205D*BA GMS81405DNCC For installations in Canada, the GMS furnaces are certifed only to 4,500 ft. * Negative pressure readings are in inches of water column (*w.c.) Mo d el T r i p P o in t ID Blo w e r P ress u re Sw i tch ID Blo w e r P ress u re Sw i tch Pa rt # G M S 804 03A * B B - 0. 70 B 1370 158 G M ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 8

    8 PRODUCT DESIGN Thermost ats: Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty Upflow Filters Cabi net Wi d t h (i n. ) Nominal Filter Siz e (in. ) A pprox . Fl ow A rea (i n 2 ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 9

    FURNACE SPECIFICA TIONS 9 1. These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation. 2. For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not be derated, orifice changes should only be made if necessary for alti ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 10

    BLOWER PERFORMANCE SPECIFICA TIONS 10 NOTES: • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. • All furnaces ship as hig-speed cooling. Installer must adjust blower cooling speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable • INSTALLATION IS TO ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 11

    11 BLOWER PERFORMANCE SPECIFICA TIONS 30 40 50 60 70 80 90 1 10 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OU T P UT B T U / HR x 10 00 BTU OUTPUT v s TEMPERA TURE RISE CHAR T TE M PE R A TU R E R ISE 600 CF M 700 900 1000 1 100 1200 1400 1600 1800 2000 2200 24 00 CF M F O RMULAS BTU OUTPUT = CFM x 1.08 x R ISE RIS E = BT U O UT P UT 800 ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 12

    12 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T A GE! DISCONNECT AL L POWE R BEFORE SERVICI NG OR INS T ALLIN G THIS UNIT . M UL TIPL E POWER SO URCES MA Y BE P RESENT . F AI LURE T O DO SO MA Y CAUS E PROPERTY DAMAG E, PERSONAL INJURY OR DEA TH. GMS8 CAP BK ( ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 13

    13 SCHEMA TICS HIGH VOL T A GE! DISCONNECT AL L POWE R BEFORE SERVICI NG OR INS T ALLIN G THIS UNIT . M UL TIPL E POWER SO URCES MA Y BE P RESENT . F AI LURE T O DO SO MA Y CAUS E PROPERTY DAMAG E, PERSONAL INJURY OR DEA TH. TYPICAL SCHEMATIC GMS8 * MODEL FURNACES WR 50T55-289 INTEGRATED IGNITION CONTROL This schematic is for reference only. Not al ...

Fabricante Goodman Mfg Categoría Furnace

Los documentos del dispositivo Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Goodman Mfg
- manuales de instrucciones GMS8 33-3/8 GAS FURNACE UNITS
- hojas de producto Goodman Mfg
- folletos informativos
- o etiquetas energéticas Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS.

El manual de instrucciones completo de Goodman Mfg debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - que deben facilitarnos los primeros pasos durante el uso de Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)