  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 1

    RT6621031r2 November 2013 This manual is to be used by qualified, professionally trained HV AC technicians only . Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures performed by an unqualified person. • Refer to Service Manual RS6612006 for troubleshooting information. • Refer to ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 2

    PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WA RNI N G WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Fail ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 3

    3 PRODUCT IDENTIFICA TION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GMS80403A*BB GMS80603A*BB GMS80604B*BB GMS80804B*BB GMS80805C*BB GMS81005C*BB GMS81205D*BA The United States Environmental Protection Agenc ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 4

    4 PRODUCT DESIGN NFPA 54/ANSI Z223.1 - latest edition. In Canada, the fur- naces must be vented in accordance with the National Stan- dard of Canada, CAN/CSA B149.1 and CAN/CSA B149.2 - latest editions and amendments. NOTE: The vertical height of the Category I venting system must be at least as great as the horizontal length of the venting system. ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 5

    5 COMPONENT IDENTIFICA TION Upflow/Horizontal 1 Tubular Heat Exchanger 2 Pressure Switch 3 Flue Pipe Connection 4 Induced Draft Blower 5 Gas Line Entrance 6 Gas Valve 7 Rollout Limit 8 Junction Box ? Pressur e Sw itch Tubul ar Heat E xchan g er Fl ue P i pe Co nn e c tion Ga s Li ne E nt ra nce (Alt e rnat e ) Ind uced Dr aft Blow er Ga s Li ne Ent ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 6

    PRODUCT DIMENSIONS 6 GMS8 A lt. Ga s Inlet H i g h Vol t ag e In le t L o w V oltage A lt. Ga s Inlet A lt. High V o lt ag e Alt. LowV oltage MOD E L A B G M S 8 04 03 A ** * G M S 8 06 03 A ** * G M S 8 06 04 B * ** G M S 8 08 04 B * ** G M S 8 08 05 C * ** G M S 8 10 05 C * ** G M S 8 12 05 D * ** G M S814 05D N ** 24 - 1/ 2 23 21 19 - 1/ 2 14 12 ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 7

    7 PRODUCT DIMENSIONS GMS8[040-100]BB GMS81205D*BA GMS81405DNCC For installations in Canada, the GMS furnaces are certifed only to 4,500 ft. * Negative pressure readings are in inches of water column (*w.c.) Mo d el T r i p P o in t ID Blo w e r P ress u re Sw i tch ID Blo w e r P ress u re Sw i tch Pa rt # G M S 804 03A * B B - 0. 70 B 1370 158 G M ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 8

    8 PRODUCT DESIGN Thermost ats: Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty Upflow Filters Cabi net Wi d t h (i n. ) Nominal Filter Siz e (in. ) A pprox . Fl ow A rea (i n 2 ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 9

    FURNACE SPECIFICA TIONS 9 1. These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation. 2. For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not be derated, orifice changes should only be made if necessary for alti ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 10

    BLOWER PERFORMANCE SPECIFICA TIONS 10 NOTES: • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. • All furnaces ship as hig-speed cooling. Installer must adjust blower cooling speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable • INSTALLATION IS TO ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 11

    11 BLOWER PERFORMANCE SPECIFICA TIONS 30 40 50 60 70 80 90 1 10 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OU T P UT B T U / HR x 10 00 BTU OUTPUT v s TEMPERA TURE RISE CHAR T TE M PE R A TU R E R ISE 600 CF M 700 900 1000 1 100 1200 1400 1600 1800 2000 2200 24 00 CF M F O RMULAS BTU OUTPUT = CFM x 1.08 x R ISE RIS E = BT U O UT P UT 800 ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 12

    12 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T A GE! DISCONNECT AL L POWE R BEFORE SERVICI NG OR INS T ALLIN G THIS UNIT . M UL TIPL E POWER SO URCES MA Y BE P RESENT . F AI LURE T O DO SO MA Y CAUS E PROPERTY DAMAG E, PERSONAL INJURY OR DEA TH. GMS8 CAP BK ( ...

  • Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - page 13

    13 SCHEMA TICS HIGH VOL T A GE! DISCONNECT AL L POWE R BEFORE SERVICI NG OR INS T ALLIN G THIS UNIT . M UL TIPL E POWER SO URCES MA Y BE P RESENT . F AI LURE T O DO SO MA Y CAUS E PROPERTY DAMAG E, PERSONAL INJURY OR DEA TH. TYPICAL SCHEMATIC GMS8 * MODEL FURNACES WR 50T55-289 INTEGRATED IGNITION CONTROL This schematic is for reference only. Not al ...

Manufacturer Goodman Mfg Category Furnace

Documents that we receive from a manufacturer of a Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS can be divided into several groups. They are, among others:
- Goodman Mfg technical drawings
- GMS8 33-3/8 GAS FURNACE UNITS manuals
- Goodman Mfg product data sheets
- information booklets
- or energy labels Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS
All of them are important, but the most important information from the point of view of use of the device are in the user manual Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS, service manual, brief instructions and user manuals Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS.

A complete manual for the device Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS.

A complete Goodman Mfg manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS, that we can find in the current document
3. Tips how to use the basic functions of the device Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS - which should help us in our first steps of using Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS?

Use the form below

If you did not solve your problem by using a manual Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS, ask a question using the form below. If a user had a similar problem with Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)