    TECHNICAL GUIDE SPLIT -SYSTEM AIR CONDITIONERS 10 SEER MODELS: H*RA018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) H*RA036 THRU 090 (3 THRU 7.5 NOMINAL TONS, 3 PH) MODELS: 018 - 060 (1 PH & 3 PH) MODELS: 076 - 090 (3 PH) Due to con tinuous p roduct improve ment, speci fica- tions are subj ect to change with out notice. Visit us on the web at www . ...

  • York THRU H*RA018 THRU 060 - page 2

    036-21121-002 Rev. A (0602 ) 2 Unitary Products Group 1. Rat ed in accordance with ARI S tandard 1 10, utilization range “A”. 2. Dua l element fuses or HACR circuit br eaker . 3. All scrolls listed with a sup erscript “B” are Bristol scrolls. All sc rolls listed w ith a superscript “C” are Copeland scrolls. 4. The Unit Charg e is correc ...

  • York THRU H*RA018 THRU 060 - page 3

    036-21121-002 Rev. A (0602) Unitary Products Group 3 COOLING CAP ACITY - Wi th Air Handler Coils UNIT MODEL AIR HANDLER COIL 1 MODEL COOLING MODEL ELECTRIC 2 HEA T KW W RA TED CFM NET MBH SEER W/O TXV SEER + TXV 3 EER TOT AL SENS. 1 PH 10 SEER AC WITH N1AH / G2FD H1RA018S06 N1AHB0806 2,5,8,10 17 G2FD024S17 650 19.0 14.1 10.50 - 9.80 H1RA024S06 N1AH ...

  • York THRU H*RA018 THRU 060 - page 4

    036-21121-002 Rev. A (0602 ) 4 Unitary Products Group COOLING CAP ACITY - Up flow , Downflow , & Horizont al Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (MIN.-MAX.) W RA TED CFM NET MBH SEER + TXV W/O TDR SEER + TXV 1 + TDR* EER TOT AL SE NS . H1RA018S06 575 725 14,17 G1F A024S14,17 650 18.0 13.3 10.00 - 9.20 14 G1F A03 ...

  • York THRU H*RA018 THRU 060 - page 5

    036-21121-002 Rev. A (0602) Unitary Products Group 5 * Requires a 2FD Blower T ime Delay unless a standa rd furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up. *** This coil is for upflow application only . H1RA036S25,46 1050 1350 17,21 G1F A036S17,21 1200 33.6 24.9 10.00 - 9.10 21,24 G1F A048S21,24 1200 3 ...

  • York THRU H*RA018 THRU 060 - page 6

    036-21121-002 Rev. A (0602 ) 6 Unitary Products Group NOTES: 1. For condensing unit only . Does not include e ffect of evaporator motor power or heat. 2. Performance based on 1 5° superheat and 1 5° sub-cooling at condensing unit. a. Increase capacity 1% for each 2° increase in sub-cooling. b. Decrease capacity 1% for each 2° decrease in sub-co ...

  • York THRU H*RA018 THRU 060 - page 7

    036-21121-002 Rev. A (0602) Unitary Products Group 7 ACCESSORIES* Refer to Price Manual for specific model numbers. Hard St art Kit - Provides increased starting torque for areas with low voltage. Compressor Blanket - Designed to further reduce the nor- mal compressor operating sound. Refer to price pages for specific match-ups. Off Cycle Timer Del ...

  • York THRU H*RA018 THRU 060 - page 8

    036-21121-002 Rev. A (0602 ) 8 Unitary Products Group TYPICAL FIELD WIRING - 1 Phase Application TYPICAL FIELD WIRING - 3 Phase Application ALL FIELD WIRING T O BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING 208/230-1-60 230-1-50 CONT ACTOR TERMINALS COIL GND. LUG CY R G W Y R GW POWER WIRING CONTROL WIRING F ACTORY WIRIN ...

  • York THRU H*RA018 THRU 060 - page 9

    036-21121-002 Rev. A (0602) Unitary Products Group 9 Multipliers for determining the performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H1RA018S06 INDOOR COIL MODEL NO. G1F A024S14 ,17 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 550 650 750 ID DB (°F) 85 80 70 85 80 70 85 80 70 ID WB (°F) 72 67 57 72 67 5 ...

  • York THRU H*RA018 THRU 060 - page 10

    036-21121-002 Rev. A (0602 ) 10 Unitary Products Group Multipliers for determining the p erformance with other indoor sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H1RA024S06 INDOOR COIL MODEL NO. G1F A024S14 , 17 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 600 800 1000 ID DB (°F) 85 80 75 70 85 80 75 70 85 80 75 70 ID WB (°F) 72 ...

  • York THRU H*RA018 THRU 060 - page 11

    036-21121-002 Rev. A (0602) Unitary Products Group 11 Multipliers for determining th e performance with other indoo r sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H2RA030S06 INDOOR COIL MODEL NO. G1F A036S17 ,21 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 800 1000 1200 ID DB (°F) 85 80 75 70 85 80 75 70 85 80 75 70 ID WB (°F) 72 ...

  • York THRU H*RA018 THRU 060 - page 12

    036-21121-002 Rev. A (0602 ) 12 Unitary Products Group Multipliers for determining th e performance with other indoo r sections. 1 Phase 3 Phase COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO . H2RA036S06, H1RA03 6S(25,46) INDOOR COIL MODEL NO. G1F A036S17 ,21 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1 150 1250 1350 ID DB (°F) 85 80 70 85 8 ...

  • York THRU H*RA018 THRU 060 - page 13

    036-21121-002 Rev. A (0602) Unitary Products Group 13 Multipliers for determining th e performance with other indoo r sections. 1 Phase 3 Phase COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H 1RA042S06, H1RA04 2S(25,46) INDOOR COIL MODEL NO. G1F A048S21 ,24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1200 1400 1600 ID DB (°F) 85 80 70 85 80 ...

  • York THRU H*RA018 THRU 060 - page 14

    036-21121-002 Rev. A (0602 ) 14 Unitary Products Group Multipliers for determining th e performance with other indoo r sections. 1 Phase 3 Phase COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO . H1RA048S06, H1RA04 8S(25,46) INDOOR COIL MODEL NO. G1F A048S21 ,24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1200 1400 1600 ID DB (°F) 85 80 75 70 85 ...

  • York THRU H*RA018 THRU 060 - page 15

    036-21121-002 Rev. A (0602) Unitary Products Group 15 Multipliers for determining th e performance with other indoo r sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H3RA060S06 INDOOR COIL MODEL NO. G1F A060S21 ,24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 2050 1800 1550 ID DB (°F) 85 80 70 85 80 70 85 80 70 ID WB (°F) 72 67 57 72 ...

  • York THRU H*RA018 THRU 060 - page 16

    036-21121-002 Rev. A (0602 ) 16 Unitary Products Group Multipliers for determining th e performance with other indoo r sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H1RA060S(25,46) INDOOR COIL MODEL NO. G2FD060S24A CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1450 1700 1950 ID DB (°F) 85 80 70 85 80 70 85 80 70 ID WB (°F) 72 67 57 ...

  • York THRU H*RA018 THRU 060 - page 17

    036-21121-002 Rev. A (0602) Unitary Products Group 17 Multipliers for determining th e performance with other indoo r sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H1RA076S(25,46) INDOOR COIL MODEL NO. K4EV090 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 2100 2600 3100 ID DB (°F) 85 80 70 85 80 70 85 80 70 ID WB (°F) 72 67 57 72 67 ...

  • York THRU H*RA018 THRU 060 - page 18

    036-21121-002 Rev. A (0602 ) 18 Unitary Products Group Multipliers for determining th e performance with other indoo r sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H1RA090S(25,46) INDOOR COIL MODEL NO. K4EV090 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 2400 3000 3600 ID DB (°F) 85 80 70 85 80 70 85 80 70 ID WB (°F) 72 67 57 72 6 ...

  • York THRU H*RA018 THRU 060 - page 19

    036-21121-002 Rev. A (0602) Unitary Products Group 19 MA TCHING INDOOR COMPONENTS G1UA 1/2 CASED UPFLOW G1HD HORIZONT AL DUCT G2FD* MUL TI-POSITION (UPFLOW , HORIZONT AL AND DOWNFLOW) * Available with factory installed horizontal drain pan. ADD-ON COILS - FOR FURNACE APPLICA TIONS G1NA UNCASED UPFLOW G1F A FULL CASED UPFLOW G2FD090 is upflow only . ...

  • York THRU H*RA018 THRU 060 - page 20

    Subject to change without notice. Printed in U .S.A. 036-21121-002 Rev. A (0602) Copyright © by York International Corp. 2002. All right s reserved. Supersedes: 036-21 121-001 Rev . A (301) Unitary 5005 Norman Product s Y ork O K Group Drive 73069 NOTES ...

Fabricante York Categoría Air Conditioner

Los documentos del dispositivo York THRU H*RA018 THRU 060 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos York
- manuales de instrucciones THRU H*RA018 THRU 060
- hojas de producto York
- folletos informativos
- o etiquetas energéticas York THRU H*RA018 THRU 060
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones York THRU H*RA018 THRU 060.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje York THRU H*RA018 THRU 060, instrucciones de servicio, instrucciones cortas o instrucciones de usuario York THRU H*RA018 THRU 060. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto York THRU H*RA018 THRU 060.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo York THRU H*RA018 THRU 060, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar York THRU H*RA018 THRU 060. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de York THRU H*RA018 THRU 060.

El manual de instrucciones completo de York debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual York THRU H*RA018 THRU 060 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice York THRU H*RA018 THRU 060, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de York THRU H*RA018 THRU 060 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo York THRU H*RA018 THRU 060 - que deben facilitarnos los primeros pasos durante el uso de York THRU H*RA018 THRU 060
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con York THRU H*RA018 THRU 060
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de York THRU H*RA018 THRU 060 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de York THRU H*RA018 THRU 060?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con York THRU H*RA018 THRU 060, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con York THRU H*RA018 THRU 060 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)