Manual de instrucciones Linear AUH-S

26 de páginas 3.17 mb
Descargar

Pasar a la página of 26

Summary
  • Linear AUH-S - page 1

    I N S T A L L A T I O N A N D OWNER’S MANUA L As of date of manufacture, meets all ANSI/UL 325 Safety Requirements for V e h i c u l a r d o o r o p e r a t o r s . AUJ-S & AUH-S AU SERIES WITH SOLI D S T A TE CONTROL CIRCUITR Y JACKSHAFT COMMERCIAL VEHICULAR DOOR OP ERA T ORS R E A D T H I S M A N U A L C A R E F U L L Y B E F O R E I N S T ...

  • Linear AUH-S - page 2

    REA D THESE STA TEMENTS CAREFUL LY AND FOLLOW T HE INSTRUCT IONS CLOSELY. The Warning and Caution boxes throughout this manual are there to protect you and your equipment. Pay close attention to these boxes as you follow the ma nual. WARNING Indicates a MEC HANICAL hazard of INJUR Y OR DEATH. Gives instruc tions to avoid the hazard. CAUTION Indicat ...

  • Linear AUH-S - page 3

    The purpose of t his booklet is to pr ovide assembly, installation and operation information con cerning Model AUJ -S & AUH-S Commercial Vehicular Garage Do or Operators and relate d Accessory Products. NOTICE IT IS IMPORTANT THAT THIS INST RUCTION MANUAL BE READ AND UNDERSTOOD COM PLETELY BEFORE INSTALLATION OR OPERATION IS ATT EMPTED. IT IS I ...

  • Linear AUH-S - page 4

    Before starting the installatio n of the operator , the door must be in good working condition and p roper ly counterbalanced. Inspec t the door and trac k for loose or missing hardware. T est the door manually for balance and ea se of oper ation. Lubricate door hinges and rollers. If necessary, e mploy a qualified tech nician to adj ust the spring ...

  • Linear AUH-S - page 5

    ITEM # PART# DESCRIPTION QUAN. 1 Operator Power Head 1 2 005 031 3 Button St ation 1 3 30 Tooth Sprocke t, 1” Bore, 1/4 Key 1 4 20 Tooth Sprocke t, 1” Bore, 1/4 key 1 5 105193 Release/Hand Ch ain Wall Brack et 1 —— AR - As Required ITEM # PART# DESCRIPTION QUAN 6 100413 1/4 ” Square Key 2 7 006 119 5/16-18 x 1 Square Head Set Screw 4 8 10 ...

  • Linear AUH-S - page 6

    F igure 4, page 8 illu strates several positions suitable for mounting the operator ; right hand or left hand, either wall mo unt or ceiling mount and ce nter mount with direct co upling to the torsion shaft. Direct coupli ng may also be used in a side mount installation. Operators inte nded for d irect coupling require an internal speed modificati ...

  • Linear AUH-S - page 7

    DIRECT COUPLING MOUNTING F igure 4, page 8 illu strates several positions suitable for mounting the operator including center mount with direct coupling to the torsion sha ft. Direct couplin g may also be used in a side mount installation. Oper ators intended for direct coupling require a n internal speed modification and must be ordered from the f ...

  • Linear AUH-S - page 8

    Figure 4 100719 Right Side Mount Ceiling Mount Left Side Mount Ceiling Mount Center Mount Direct Couple W all Mount W all Mount 8 FIGURE 4 - OPE R A TOR MOUNT ING POSITIONS ...

  • Linear AUH-S - page 9

    107173 Figure 5 NOTE: Dim ensions for Model AUJ -S are s imilar to above, Model AUJ-S is not provide d with a chain hoist. 9 FIGURE 5 - OPE RA TOR DIMENSIONS - MODEL AUH-S 7.75 ...

  • Linear AUH-S - page 10

    10 FIGURE 6 - OPE R A TOR DIMENS IONS - MO DEL AUJ-S 107173 Figure 6 NOTE: Dim ensions for Model AUH -S are s imilar to ab ove, Model AUH-S is pro vided with a chain hoist. 15 7.75 ...

  • Linear AUH-S - page 11

    4) Depress the limit nut retaining Plate (D) so it disengages from t he slots in the limit n uts. Turn the OPEN li mit n ut (E) on the shaft until it engages the Open Limit Switch (A). You will need to liste n for an audible click. Release the retaini ng plate and be sure that it engage s in slots of bo th limit nuts. 5) Manually lower the door to ...

  • Linear AUH-S - page 12

    RISK OF ENT R APMENT THAT MAY RESULT IN SERIOUS PERS ONAL INJUR Y OR DEATH. DISC O NNECT PO WER TO THE OPENER BE FORE AND DUR ING INSTA LLATION OF AN ACCESSORY REVERS ING DOOR EDGE OR PHOTOELE CTRIC DEVICE. DO NOT RECONNE CT POWER T O OPENER U NT IL IN ST R U CT ED T O DO S O. EN SU RE D O OR WA Y IS C LEA R BE FO RE S TA R T ING T ES T IN G OF W A ...

  • Linear AUH-S - page 13

    9. See Figure 9 for connecting the photoelectric device to the operator. See P age 17 for proper setting of the selector switches. These switches must be proper ly set and an approved p hotoelectric device or approved doo r edge device connected to the oper ator to o btain B2 Mod e of Operation, Momentary Contact to C lose. DOOR EDGE an d PHOTOELEC ...

  • Linear AUH-S - page 14

    MOTOR CONTROL BOARD Figure 9 OPEN TB1 STOP CLOSE OPEN COM CLOSE STOP NO REV NC REV PHOTO COM SINGLE ILOCK 24 VAC COM SAFE FINISH PHOTOBE AM 3-WIRE PHOTOBEAM Door Edge and Photoelectric Wiring INST ALLA TI ON INSTRUCTI ONS 14 After properly connecting a n appro ved Entrapment Protection Device (see above and Page 3 ) to the operator, see Page 17 for ...

  • Linear AUH-S - page 15

    15 NOTE: It is now necessary to turn on the pow er in order to change the Operating Mo de (if applicable), progra m any changes des ired to the operator’s ot her settings, c heck for pr oper performance of all th e operator’s feature s to include the brake (if applicab le) and clutc h (adjusting settings if necessary); and to set and finalize a ...

  • Linear AUH-S - page 16

    Understand all of the operating features of your door contr ol system at the time of its installation. Your installing dealer will demonstr ate them for you. NEVER let children operate or play with door controls. Keep the Remote Control (where provided) away from children. Personnel should keep away from a door in motion and keep the moving door in ...

  • Linear AUH-S - page 17

    Changing the Sw itch Selectable Opera tion Modes The following modes are selected b y setting the on -board dip switches, Figure 20 at right sho ws where the switches are located on the oper ator control boar d. For each Operational Mode, the switches are set to either ON or OFF ac cording to the table at right belo w. For all the modes, if an appr ...

  • Linear AUH-S - page 18

    Mid -Stop : Activation stops an op ening door; momentary con tact of open button at mid stop will restart d oor to full open position; if door is moving open, consta nt pressure on o pen button will bypass mid-stop . Auto Close Timer : N/ A TS Operation Open Button : Momentary activation; op en override of closi ng door. Close Button : M omentary a ...

  • Linear AUH-S - page 19

    The solenoid o perated brake may require occ asional adjustment. Adjustment i s necessary if doo r tends to drift downward after reachi ng the open limit. Follo w the instructions belo w and use Figure 14 as a guide. (1) Loosen shoe adj usting screw and bottom bracket arm of solenoid. (2) Move tab until drum has a slight drag. (3) Reverse drag slig ...

  • Linear AUH-S - page 20

    CLUTCH ADJUSTME NT The clutch serves to pr otect the do or, the electric operato r and other equipment from undue s tress or damage caused by starting forces and/or an obstructio n to the door. It should be set no tighter than is necessar y to smoothly and consiste ntly move the door throughout its full ra nge of travel. When prop erly set, it will ...

  • Linear AUH-S - page 21

    OPERA T ION & ADJUSTME NT INSTRUCTI ONS 21 ...

  • Linear AUH-S - page 22

    Normally, very little maintenance is required. A mon thly visual inspection must be made for loose or missing hardware and for excessive slack in the V -Belt and j ackshaft chain. The clutc h must be tested perio dically and adjustments made if necessary (see page 20 ). T he brake is adjusted at the factory and will need periodic adj ustment for we ...

  • Linear AUH-S - page 23

    WIRING DI AGRA M/S CHEM A TIC - SIN GLE PHASE 23 575 VOL TS, 3 PHASE SINGLE VOL T AGE MOTOR BL/BLK BL/BLK TO REVERSE MOT OR, SWITCH LEADS 1 & 3 L1 4 L2 YELLOW WHITE BLACK ORANGE BLUE RED Wire Nut Connection 3 BLUE (T ,J,H) YELLOW BLUE RED BLACK A.O. SMITH SINGLE VOL T AGE - 1 15 V AC, 1P MOTOR RED (AU) YELLOW 3 2 1 4 Wire Nut Connection L1 L2 1 ...

  • Linear AUH-S - page 24

    WIRING DI AGRA M/S CHEM A TIC - THREE PH ASE 24 575 VOL TS, 3 PHASE SINGLE VOL T AGE MOTOR BL/BLK BL/BLK TO REVERSE MOT OR, SWITCH LEADS 1 & 3 L1 4 L2 YELLOW WHITE BLACK ORANGE BLUE RED Wire Nut Connection 3 BLUE (T ,J,H) YELLOW BLUE RED BLACK A.O. SMITH SINGLE VOL T AGE - 1 15 V AC, 1P MOTOR RED (AU) YELLOW 3 2 1 4 Wire Nut Connection L1 L2 1 ...

  • Linear AUH-S - page 25

    P ARTS IDENTIFIC A TION 25 Ref Part# Description Assemblies A 109351 Frame Assembly w/Sha f ts. AUJ 109358 Frame As sembly w/Shaft s, AUH C 110076 Clutch Shaft Assembly, AUJ 110077 Clutch Shaf t Assembly w /Hoist, AUH E 109848 Secondary Shaft Asse mbly, AUJ / H (1/3 HP) 109274 Secondary Shaft Assembly, AUJ / H (1/2 & 3/4 HP) G 109273 Brake Asse ...

  • Linear AUH-S - page 26

    26 SPECIFICATIONS MODEL : AUJ_ _ _ _S HP:_____ VOLTS : _____ PHASE : _____ * UL AND CANADIAN UL LIS TED * HIGH STARTING TORQUE, CONTINUOUS DUTY MOTO R * MOTOR OVERLOAD PROTECTI ON * CLASS 2 (24 VOLT) CONTROL CI RCUIT * SOLENOID BRAKE * SOLID STATE MOTOR CONTRO L CIRCUITRY WITH * THREE BUTTON CONTROL: OPEN , CLOSE, STOP * HEAVY GAUGE, POWDER- COATED ...

Fabricante Linear Categoría Garage Door Opener

Los documentos del dispositivo Linear AUH-S que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Linear
- manuales de instrucciones AUH-S
- hojas de producto Linear
- folletos informativos
- o etiquetas energéticas Linear AUH-S
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Linear AUH-S.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Linear AUH-S, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Linear AUH-S. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Linear AUH-S.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Linear AUH-S, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Linear AUH-S. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Linear AUH-S.

El manual de instrucciones completo de Linear debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Linear AUH-S - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Linear AUH-S, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Linear AUH-S que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Linear AUH-S - que deben facilitarnos los primeros pasos durante el uso de Linear AUH-S
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Linear AUH-S
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Linear AUH-S en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Linear AUH-S?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Linear AUH-S, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Linear AUH-S probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)