Manuel d’utilisation Weil-McLain 310

12 pages 0.49 mb
Télécharger

Aller à la page of 12

Summary
  • Weil-McLain 310 - page 1

    V ent Supplement This document must only be used by a qualified heating installer/service technician. Read all instructions, including this Supplement and the Boiler Manual, before installing. P erform st eps in the order given. Failure to c omply could r esult in se ver e pe rsonal inju r y , d eath or substantial property damag e. Installation mu ...

  • Weil-McLain 310 - page 2

    Part number 550-101-235/0903 2 GAS - FIRED WA TER BOILER — V ent Supplement Please read before proceeding Installer Read all instructions before installing. Follow all instructions in proper order to prevent personal injury or death. • This document is intended only as a supplement to the Ultra Boiler Manual. It’ s purpose is fo r the install ...

  • Weil-McLain 310 - page 3

    Part number 550-101-235/0903 3 GAS - FIRED WA TER BOILER — V ent Supplement V ent and air piping materials Use only the materials listed in the table below for vent and air pipe and fittings. Failure to comply could result in sever e personal injur y , death or substantial pr opert y damage. 1 Installation must comply with local requirements and ...

  • Weil-McLain 310 - page 4

    Part number 550-101-235/0903 4 GAS - FIRED WA TER BOILER — V ent Supplement Pr epare boiler location V ent and air piping Vent and air system Installation must comply with local requir ements and with the National F uel Gas Code, ANSI Z223.1 fo r U.S. installations or CSA B149.1 or B149.2 for Canadian installations. The Ultra boiler requires a sp ...

  • Weil-McLain 310 - page 5

    Part number 550-101-235/0903 5 GAS - FIRED WA TER BOILER — V ent Supplement Pr epare boiler location (continued) Table 1 Corrosive contaminants 2 T o preve nt the p otential of severe personal injury or death, check for areas and pr oducts listed in T able 1 before installing the boiler or air inlet piping. If contaminants are found, you MUST : ? ...

  • Weil-McLain 310 - page 6

    Part number 550-101-235/0903 6 GAS - FIRED WA TER BOILER — V ent Supplement V ent/air ter mination — thr ough r oof 3 Figure 1 V er tical termination of air & vent Determine location Locate the vent/air terminations using the following guidelines: 1. The total length of piping for vent or air must not ex ceed the limits given in T able 2, p ...

  • Weil-McLain 310 - page 7

    Part number 550-101-235/0903 7 GAS - FIRED WA TER BOILER — V ent Supplement V ent/air ter mination — thr ough r oof (continued) 3 Prepare roof penetrations 1 . Air pipe penetration: a. Cut a hole for the air pipe. Size the air pipe hole as close as desired to the air pipe outside diamet er . 2 . V ent pipe p enetrat ion: a . Cut a hole for the ...

  • Weil-McLain 310 - page 8

    Part number 550-101-235/0903 8 GAS - FIRED WA TER BOILER — V ent Supplement V ent/air ter mination — sidewall 4 Determine location Locate the vent/air terminations using the following guidelines: 1. The total length of piping for vent or air must not ex ceed the limits given in T able 2, page 12. 2 . The air piping must terminate in a down-turn ...

  • Weil-McLain 310 - page 9

    Part number 550-101-235/0903 9 GAS - FIRED WA TER BOILER — V ent Supplement Prepare wall penetrations 1. Air pipe penetration: a. Cut a hole for the air pipe. Size the air pipe hole as close as desired to the air pipe outside diameter . 2. V ent pipe pene trat ion: a . Cut a hole for the vent pipe. For either combustible or noncombustible constru ...

  • Weil-McLain 310 - page 10

    Part number 550-101-235/0903 10 GAS - FIRED WA TER BOILER — V ent Supplement Figure 7 Multiple vent/air terminations (must also comply with Figure 4) Figure 8 Multiple vent/air terminations (must also comply with Figure 4) (Apply this method only where exit openings are too low to provide minimum 12 inch clearance above grade/snow line.) V ent/ai ...

  • Weil-McLain 310 - page 11

    Part number 550-101-235/0903 11 GAS - FIRED WA TER BOILER — V ent Supplement Installing vent & air piping 5 Inserting/securing vent or air pipe into boiler adapters 1 . Clean and chamfer insertion end of pipe. Deburr inside of insertion end. Clean and deburr inside and outside of other end of pipe. The pipe end must be smooth and chamfered to ...

  • Weil-McLain 310 - page 12

    Part number 550-101-235/0903 12 GAS - FIRED WA TER BOILER — V ent Supplement Installing vent & air piping (continued) 5 Figure 10 Piping to through-roof terminations Figure 9 Piping to sidewall terminations Ta b l e 2 Min/max lengths of either air piping or vent piping When a large number of elbows is needed with 3-inch piping, use long radiu ...

Fabricant Weil-McLain Catégorie Boiler

Les documents que nous recevons du fabricant de l'appareilWeil-McLain 310 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Weil-McLain
- manuels d’utilisations 310
- fiches produit Weil-McLain
- dépliants
- ou étiquettes-énergie Weil-McLain 310
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Weil-McLain 310.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Weil-McLain 310, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Weil-McLain 310. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Weil-McLain 310.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Weil-McLain 310, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Weil-McLain 310 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Weil-McLain 310.

Le manuel d’utilisation complet Weil-McLain, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Weil-McLain 310 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Weil-McLain 310, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lWeil-McLain 310 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Weil-McLain 310 - qui devraient nous aider dans les premières étapes lors de l'utilisation Weil-McLain 310
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Weil-McLain 310
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Weil-McLain 310 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Weil-McLain 310?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Weil-McLain 310, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Weil-McLain 310 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)