    1 W415-0514 / 05.30.05 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .continentalfireplaces.com • ask@continentalfire.com GAS-FIRED STOVES INST ALLA TION AND OPERA TION INSTRUCTIONS FOR: VENTED GAS FIREPLACE H ...

  • Continental CDVS500-P - page 2

    2 W415-0514 / 05.30.05 Pg 2 -4 INTRODUCTION Warranty General Instructions General Information Care of Glass & Plated Parts 5 LOCA TION & CLEARANCES 6-11 DIRECT VENT SPECIFICS MODEL CDVS500 V ent Lengths/Air T erminal Locations Special Installation Example Offset Installation Example Wall & Ceiling Protection Horizontal V enting Installa ...

  • Continental CDVS500-P - page 3

    3 W415-0514 / 05.30.05 CONTINENTAL gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. CONTINENTAL products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and te ...

  • Continental CDVS500-P - page 4

    4 W415-0514 / 05.30.05 FOR YOUR SA TISF ACTION, THIS STOVE HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUAL- ITY! Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 1 1 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane. Mani ...

  • Continental CDVS500-P - page 5

    5 W415-0514 / 05.30.05 As long as clearance to combustibles is kept within the required distances, the most desirable and benefical location for a Continental stove is in the centre of a building, thereby allowing the most efficient use of the heat created. The loca- tion of windows, doors and the traffic flow in the room where the stove is to be l ...

  • Continental CDVS500-P - page 6

    6 W415-0514 / 05.30.05 Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp or American Metal Amerivent venting components. For Simpson Dura-Vent, Selkirk Direct Temp and American Metal Amerivent, follow the installation procedure provided with the venting components. For vent systems that provide seals on the inner exhaust flue, only the ou ...

  • Continental CDVS500-P - page 7

    7 W415-0514 / 05.30.05 AIR TERMINAL INST ALLA TIONS * * * Recommended to prevent condensation on windows and thermal breakage * * * * * * * * * * It is recommended to use a heat shield and to maximize the distance to vinyl clad sof fits . *** *** *** *** ** * The periscope GD-201 r equires a minimum 18 inc hes clear ance from an inside corner . *** ...

  • Continental CDVS500-P - page 8

    8 W415-0514 / 05.30.05 5 7 " f ir s t r u n 7 2 " s e c o n d r u n 4 8 " Use the chart on this page to calculate horizontal runs for vertical rises between 29 and 57 inches. FIGURE 8. When calculating maximum run lengths, include 10 feet for each 90° elbow or 5 feet for each 45° elbow . (DO NOT INCLUDE THE FIRST ELBOW DIRECTL Y OF ...

  • Continental CDVS500-P - page 9

    9 W415-0514 / 05.30.05 This application occurs when venting through an ex- terior wall. FIGURES 5 , 6, & 13 . Having deter- mined the air terminal loca- tion, cut and frame a hole in an exterior wall with a mini- mum square or round open- ing of 9". (As an alternative to framing, a vent pipe shield may be installed, en- suring a 1" cl ...

  • Continental CDVS500-P - page 10

    10 W415-0514 / 05.30.05 FIGURE 17 FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA TION OF THE TION OF THE TION OF THE TION OF THE TION OF THE ST ST ST ST ST O O O O O VE, FOLL VE, FOLL VE, FOLL VE, FOLL VE, FOLL O O O O O W THE VENTING INSTR W THE VENTING INSTR W THE ...

  • Continental CDVS500-P - page 11

    11 W415-0514 / 05.30.05 In Canada, mobile home installation may be vented hori- zontally or vertically . In the United S tates, it may only be installed vertically . See "V ertical V enting" or "Horizontal Air T erminal Installation" for inst allation. The fireplace is equipped with two 5/16" diameter holes located near eac ...

  • Continental CDVS500-P - page 12

    12 W415-0514 / 05.30.05 Follow the instructions for " Wall and Ceiling Protection". ADAPTER INST ALLA TION FIGURE 27 1. Remove the spill switch bracket from the rear of the adapter . 2. Gently pull the two wire terminals (located inside the 7" flue collar at the top of the stove) out approximately 8 inches. 3. Bring the wires through ...

  • Continental CDVS500-P - page 13

    13 W415-0514 / 05.30.05 Remove nails from the shingles above and to the sides of the chimney . Place the flashing over the vent pipe and slide it underneath the sides and upper edge of the shingles. Ensure that the vent pipe is properly centered within the flashing, giving a 3/4" margin all around. Fasten to the roof on the top and sides. DO N ...

  • Continental CDVS500-P - page 14

    14 W415-0514 / 05.30.05 Read the section on opening the door in "Finish- ing" prior to proceeding to prevent damaging the unit. Bring the gas line to the stove through either the opening in the pedestal back or through the floor directly beneath the pedestal base. Install rigid black pipe or ½" type L copper tubing with a shut-off v ...

  • Continental CDVS500-P - page 15

    15 W415-0514 / 05.30.05 When opening the fire viewing door , a simple procedure must be followed in order to not damage the door . First open the valve control door . Next open both side doors fully . Pull the latch handles towards you and release each catch. The door may now be safely opened. T o close the door , repeat in reverse order . There ma ...

  • Continental CDVS500-P - page 16

    16 W415-0514 / 05.30.05 LOG PLACEMENT POSITIONING THE LOGS IMPROPERL Y WILL CAUSE FLAME IMPINGEMENT AND CARBONING . PHAZER TM logs and charcoal embers strips, exclusive to Continental Fireplaces, glow when exposed to direct flame and provide a unique and realistic glowing effect that is dif- ferent in every installation. Use only certified PHAZER T ...

  • Continental CDVS500-P - page 17

    17 W415-0514 / 05.30.05 This is a thermally activated switch, attached to the back of the chimney adapter , which senses the change in temperature and shuts down the gas valve in the event of a severe downdraft of air or a blocked or disconnected vent. It acts as a safety shut-off to prevent a build up of carbon monoxide or an explosion of unburnt ...

  • Continental CDVS500-P - page 18

    18 W415-0514 / 05.30.05 TURN OFF THE GAS AND UNPLUG ELECTRI- CAL POWER BEFORE SERVICING THE STO VE! CAUTION: Label all wires prior to disconnection when ser- vicing controls. Wiring errors can cause improper and dan- gerous operation. V erify proper operation after servicing. This insert and its venting system should be inspected before use and at ...

  • Continental CDVS500-P - page 19

    19 W415-0514 / 05.30.05 1. Turn off the electrical power and the gas supply to the stove. 2. Open the lower louvre control door , the two side doors, and the fire viewing door . Remove the logs. 3. Remove the relief door held on with 6 screws. Discard the gasket. 4. Disconnect the two blower wires. Remove the blower bracket held on with 4 screws. 5 ...

  • Continental CDVS500-P - page 20

    20 W415-0514 / 05.30.05 Remove the pilot screw cap. Adjust the pilot screw to pro- vide properly sized flame. Turn in a clockwise direction to reduce the gas flow . Replace the pilot screw cap. FIGURE 46 FIGURE 47 FIGURE 48 Air shutter adjustment must only be done by a qualified gas installer! FIGURE 49 T o access the venturi, remove the screw secu ...

  • Continental CDVS500-P - page 21

    21 W415-0514 / 05.30.05 GD175 WALL TERMINAL KIT 44 BM6790 90° ELBOW - 7" DIAMETER 45 GD222 TERMINAL ASSEMBL Y 4 6 BM67ADJ 30" TO 53" ADJUST ABLE PIPE - 7" DIA 4 7 W500-0077 FIRESTOP / WALL PLA TE 4 8 W020-0032 HARDWARE 49 BRTC7 BRASS TRIM COLLAR 50 BM6724 24" STOVE PIPE - 7" DIAMETER 5 1 W010-0300 10' ALUMINUM FL ...

  • Continental CDVS500-P - page 22

    22 W415-0514 / 05.30.05 WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf S teel Ltd. ...

  • Continental CDVS500-P - page 23

    23 W415-0514 / 05.30.05 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed. - replace the electrode if the ceramic insulator is cracked or broken. - replace the ...

  • Continental CDVS500-P - page 24

    24 W415-0514 / 05.30.05 Main burner goes out; pilot goes out. REFER TO "MAIN BURNER GOES OUT ; PILOT ST A YS ON" Thermocouple shorting or faulty . V ent re-circulating (MODEL CDVS500 ONL Y) - check joint seals and installation. - loosen and tighten thermocouple - clean thermocouple and valve connection. - replace thermocouple. - replace v ...

Fabricant Continental Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilContinental CDVS500-P peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Continental
- manuels d’utilisations CDVS500-P
- fiches produit Continental
- dépliants
- ou étiquettes-énergie Continental CDVS500-P
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Continental CDVS500-P.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Continental CDVS500-P, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Continental CDVS500-P. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Continental CDVS500-P.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Continental CDVS500-P, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Continental CDVS500-P par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Continental CDVS500-P.

Le manuel d’utilisation complet Continental, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Continental CDVS500-P - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Continental CDVS500-P, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lContinental CDVS500-P qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Continental CDVS500-P - qui devraient nous aider dans les premières étapes lors de l'utilisation Continental CDVS500-P
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Continental CDVS500-P
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Continental CDVS500-P dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Continental CDVS500-P?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Continental CDVS500-P, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Continental CDVS500-P il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)