    1 W415-0385 / A / 10.02.03 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon R d., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .continentalfireplaces.com • ask@continentalfire.com R-2000 CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS, CSA 2.33, ANSI ...

  • Continental BCDV42N - page 2

    2 W415-0385 / A / 10.02.03 WARNING • • • • • Do not burn wood or other ma terials in this fireplace . • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the fir eplace . • Due ...

  • Continental BCDV42N - page 3

    3 W415-0385 / A / 10.02.03 CONDITIONS AND LIMIT A TIONS WOLF STEEL LTD. warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or l egal entity (registered customer) whose name appears on the warranty registration card filed with WOLF STEEL Ltd. -- provided that the purchase was made through an au ...

  • Continental BCDV42N - page 4

    4 W415-0385 / A / 10.02.03 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERV - ICED BY A QUALIFIED INST ALLER to conform with local codes. In absence of local codes, install the B CDV42 to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes. Installation practices vary from region to region and it is impo ...

  • Continental BCDV42N - page 5

    5 W415-0385 / A / 10.02.03 Use only Wolf S teel or Simpson Dura-V ent Model DV -GS venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air termi- nal locations for either system are set out in this manual and must be adhered to. For Simpson Dura-V ent, follow the installation procedure provided ...

  • Continental BCDV42N - page 6

    6 W415-0385 / A / 10.02.03 * Recommended to prevent condensation on windows and thermal breakage ** Using a Napoleon soffit heat shield, W585-0096, or equivalent, the distance may be reduced to a minimum of 18". It is recommended to maximize the distance to vinyl clad soffits. *** The periscope GD-401 requires a minimum 18 inches clearance fro ...

  • Continental BCDV42N - page 7

    7 W415-0385 / A / 10.02.03 Use the GD401 periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12 inches above grade. The maximum allow- able vent length depends on the fireplace, as illustrated. FIGURES 3 a-c FIGURE 4 TYPICAL VEN ...

  • Continental BCDV42N - page 8

    8 W415-0385 / A / 10.02.03 VER VER VER VER VER TICAL TICAL TICAL TICAL TICAL TERMIN TERMIN TERMIN TERMIN TERMIN A A A A A TION TION TION TION TION HORIZONT HORIZONT HORIZONT HORIZONT HORIZONT AL AL AL AL AL TERMIN TERMIN TERMIN TERMIN TERMIN A A A A A TION TION TION TION TION vertical rise vertical rise vertical rise vertical rise vertical rise is ...

  • Continental BCDV42N - page 9

    9 W415-0385 / A / 10.02.03 ELBO W VENT LENGTH V AL UES DEFINITIONS HORIZONT AL TERMINA TION REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE 5 45º FIGURE 6 90° H 1 H 2 when (H T ) < (V T ) Simple venting configuration (only one 45º and 90° elbow) for the following symbols used in the v ...

  • Continental BCDV42N - page 10

    10 W415-0385 / A / 10.02.03 V 1 HORIZONT AL TERMIN A TION See graph to determine the re- quired vertical rise V T for the re- quired horizontal run H T . For vent configurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula 2: H T + V T < 24.75 feet FIGURE 7 REQUIRED VERTICAL RISE I ...

  • Continental BCDV42N - page 11

    11 W415-0385 / A / 10.02.03 VERTICAL TERMIN A TION Example 3: V 1 =5 f t V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 =3 f t H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.5 + 5.4 = 10.9 ft H T + V T = 10.9 + 15 = 25.9 ft Formula 1: H T < V ...

  • Continental BCDV42N - page 12

    12 W415-0385 / A / 10.02.03 H 1 VERTICAL TERMIN A TION For vent configurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2: H T + V T < 40 fee t Example 4: when (H T ) > (V T ) Simple venting configurations See graph to determine the required vertical rise V T for the ...

  • Continental BCDV42N - page 13

    13 W415-0385 / A / 10.02.03 This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Con- tinental dealer . See Ac- cessories to order the specific kit required. 1. Determine the air terminal location, cut and frame 10 inch openings in the ceiling and the roof to provide the minimum 1 i ...

  • Continental BCDV42N - page 14

    14 W415-0385 / A / 10.02.03 Use only approved aluminum flexible liner kits marked: "Wolf Steel Appr oved V enting" as identifi ed by the stamp only on the 8” outer liner . FIGURE 18 F or safe and proper operation of the fireplace, follow the venting instr uctions e xactly . A VENT HEA T SHIELD MUST BE USED IF THE W ALL TERMI- NAL IS INS ...

  • Continental BCDV42N - page 15

    15 W415-0385 / A / 10.02.03 FIGURE 25 The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf S teel vent spacers every 3 feet and either side of each elbow to maintain the minimum 1¼" clearance between the outer and inner vent pipes. Use Wolf S teel support ring assem- bly or equivalent no ...

  • Continental BCDV42N - page 16

    16 W415-0385 / A / 10.02.03 V ertical terminations may display a very active flame. If this appearance is not desirable, the vent exit must be restricted using restrictor plate, W080-0454. This reduces the veloc- ity of the exhaust gases, slowing down the flame pattern and creating a more traditional appearance. Proceed once the vent installation i ...

  • Continental BCDV42N - page 17

    17 W415-0385 / A / 10.02.03 It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4's and frame to local building codes. FIGURES 31-33. It is not necessary to install a hearth extension with this fireplace system. When roughing in the fireplace, raise the fireplace to ac- commodate for the thickness ...

  • Continental BCDV42N - page 18

    18 W415-0385 / A / 10.02.03 NAILING TA B 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts. If there are no existing holes, follow these instructions: Position the nailing tab so that ...

  • Continental BCDV42N - page 19

    19 W415-0385 / A / 10.02.03 1. Remove the upper louvres, and open the glass door . Remove the logs. 2. Remove the securing screw al- ready in place at the back of the fire- box. If the unit is supplied with a rear log support, remove before install- ing the rear brick panel. Place the rear panel against the back of the firebox and re-install the re ...

  • Continental BCDV42N - page 20

    20 W415-0385 / A / 10.02.03 4. Cradle the notch on the bottom of the left crossover log (#4) around the left outermost grate post and the top into the pocket provided on the back log. Position the notch located on the end of the center log (#5) against the middle grate post with the other end of the log resting in the pocket of the left crossover l ...

  • Continental BCDV42N - page 21

    21 W415-0385 / A / 10.02.03 INST ALLA TION T O BE DONE BY A QUALIFIED INST ALLER and must be electrically connected and grounded in ac- cordance with local codes. In the absense of local codes, use the current CSA C22.1 C ANADIAN ELECTRICAL CODE in Canada or the ANSI/NFP A 70 NA TIONAL ELECTRICAL CODE in the United S tates If the fireplace was not ...

  • Continental BCDV42N - page 22

    22 W415-0385 / A / 10.02.03 ELECTRICAL INST ALLA TION TO BE DONE BY A QUALI- FIED INST ALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 C ANADIAN ELECTRICAL CODE in Canada or the ANSI/NFP A 70 NA TIONAL ELECTRICAL CODE in the United S tates. T o safely install the fan, ...

  • Continental BCDV42N - page 23

    23 W415-0385 / A / 10.02.03 GAS KNOB P I L O T H I O L P O F F L O P I N O L O T F F O When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condi- tion caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will n ...

  • Continental BCDV42N - page 24

    24 W415-0385 / A / 10.02.03 Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow . Air shutters have been factory set open according to the chart below: These settings are for the maximum horizontal vent run.- Adjustment may be required depending on fuel type, vent configuration and altitude. ...

  • Continental BCDV42N - page 25

    25 W415-0385 / A / 10.02.03 # P ART N O. DESCRIPTION 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 *W680-0005 THERMOCOUPLE 4 W010-0800 NA TURAL GAS PILOT ASSEMBL Y 4 W010-0801 PROP ANE GAS PILOT ASSEMBL Y 5* W573-0008 HIGH TEMPERA TURE SEALANT 6 W455-0069 NA TURAL GAS PILOT INJECTOR 6 W455-0067 PROP ANE GAS PILOT INJECTOR 7 W725-0025 NA TURAL ...

  • Continental BCDV42N - page 26

    26 W415-0385 / A / 10.02.03 ...

  • Continental BCDV42N - page 27

    27 W415-0385 / A / 10.02.03 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed. - replace the electrode if the ceramic insulator is cracked or broken. - replace ...

  • Continental BCDV42N - page 28

    28 W415-0385 / A / 10.02.03 Pilot goes out while standing; Main burner is in 'OFF' position. Gas piping is undersized. - turn on all gas appliances and see if pilot flame flutters, dimin- ishes or extinguishes, especially when main burner ignites. Monitor appliance supply working pressure. - check if supply piping size is to code. Correct ...

Fabricant Continental Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilContinental BCDV42N peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Continental
- manuels d’utilisations BCDV42N
- fiches produit Continental
- dépliants
- ou étiquettes-énergie Continental BCDV42N
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Continental BCDV42N.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Continental BCDV42N, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Continental BCDV42N. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Continental BCDV42N.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Continental BCDV42N, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Continental BCDV42N par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Continental BCDV42N.

Le manuel d’utilisation complet Continental, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Continental BCDV42N - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Continental BCDV42N, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lContinental BCDV42N qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Continental BCDV42N - qui devraient nous aider dans les premières étapes lors de l'utilisation Continental BCDV42N
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Continental BCDV42N
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Continental BCDV42N dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Continental BCDV42N?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Continental BCDV42N, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Continental BCDV42N il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)