  • Agilent Technologies 81200 - page 1

    Agilent 81200 The 81200 Data Generator/ Analyzer Platform Configuration Guide Release 2.1 Simplify your verification and characterization process ...

  • Agilent Technologies 81200 - page 2

    The Agilent T echnologies 81200 data generator/analyzer platform The A gilent 81200 is a modular plat- form consisting of front-ends, mod- ules, mainframes and user int erfaces, which can be tailored to your specific test needs. This guide aims t o help you choose the right components. In this context, tw o dif ferent fundamen- tal possibilities in ...

  • Agilent Technologies 81200 - page 3

    3 Product Description Model Number Quantity Generator front-ends Generator front-ends 660MHz, RZ/NRZ, 3.5 Vpp, variable transition times SMA (f). Agilent E4838A Generator front-end 330 MHz, RZ/NRZ, variable transition times SMA (f). Agilent E4842A Generator front-end 660 MHz, RZ/NRZ, single channel, 2.5 Vpp SMA (f). Agilent E4843A Dual generator fr ...

  • Agilent Technologies 81200 - page 4

    4 Expander frames F or more module slots, one or tw o Agilent E4848B expander frames can be connect ed. To do this, a VXI exten- der module (Agilent E4849B Opt 002) is required. The module occupies one of t he ot herwise free slots and is con- nected to a cor responding VXI exten- der t hat is supplied as par t of the expander frame. Note t hat, wh ...

  • Agilent Technologies 81200 - page 5

    STEP 5: Choosing the user inter- face, support options, installation options, and test accessories User Interface The compact choice is the display and entr y panel that mounts onto the front of the mainframe and hinges f or optimum viewing/connector access. It can only be used when connected to the frames A gilent E4840A and Agilent E4849B in the ...

  • Agilent Technologies 81200 - page 6

    6 Controlling instruments with the Agilent 81200 (only for "proprietary systems") The embedded PC of t he frames Agilent E4849B and Agilent E4840A includes a GPIB inter face so that other GPIB instr uments can be con- trolled with the Agilent 81200 plat- form (f igure 6). To do t his, you need to install suitable controller sof tware such ...

  • Agilent Technologies 81200 - page 7

    7 DUT Fixturing F or conv enient and reliable DUT fix- turing for DUT’s wit h up to 192 pins, there is t he A gilent E4839A Test Fixture available. F or details, please consult Agilent E4839A Test Fixture, data sheet, p/n 5968-3580E. Simulation data link for VHDL and V erilog BestLink/81200, a simulation data link is available t o process and tra ...

  • Agilent Technologies 81200 - page 8

    8 Upgrading an existing Agilent 81200 data generator/analyzer platform The A gilent 81200 Dat a Generat or/ Analyzer Platform can be extended or adapted as needed. Front-ends, mod- ules and expander frames can be added at any time. Orders for individ- ual units are supplied wit h t he inst al- lation instr uctions. User software upgrades Revisions ...

  • Agilent Technologies 81200 - page 9

    9 Systems needing more than ten module slots The A gilent E4849B mainframe can be ext ended using the Agilent E4848B expander frame. The maximum con- figuration with one expander is: • Agilent E4849B mainframe • Option 001 display and entr y panel (ormonit or/k eyboard/mouse options) • Option 002 VXI extender module • Agilent E4805A clock m ...

  • Agilent Technologies 81200 - page 10

    I Fax Co v er Sheet A gilent 81200 Conf iguration Guide To : OFC/BVS A gilent T echnologies GmbH, Herrenberger Straße 130, 71034 Böblingen, Ger man y F ax Number : +49 (7031) 464-6532 If y ou ha ve problems wit h t his fax, please cont act: +49 (7031) 464-7 67 4 From: Name: Compan y: T elephone: Email: Sales represent ativ e: Agilent order no. (m ...

  • Agilent Technologies 81200 - page 11

    III Configuration Sheet: E4840A Small Frame Please choose one of t he front- ends: E4837A E4838A E4843A E4844A E4845A E4846A E4847A and writ e t he product number (e.g. E4837A) in the appropriate slot Front-End 4 Front-End 3 Front-End 2 Front-End 1 0 1 2 E4805A E4831A E4841A E4831A E4841A E4831A  Slot ...

  • Agilent Technologies 81200 - page 12

    V Configuration Sheet: Mainframe E4849B as standalone frame 1 23 4 5 6 7 8 9 0 10 11 12 Front-End 1 Fr ont-End 2 Front-End 3 Front-End 4 E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A Please choose one of the front-ends: E4837A, E4838A, ...

  • Agilent Technologies 81200 - page 13

    VII 1 23 4 5 6 7 8 9 0 10 11 12 Front-End 1 Fr ont-End 2 Front-End 3 Front-End 4 E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A Please choose one of the front-ends: E4837A, E4838A, E4843A, E4844A, E4845A, E4846A, E4847 and write the pro ...

  • Agilent Technologies 81200 - page 14

    IX 1 23 4 5 6 7 8 9 0 10 11 12 Front-End 1 Fr ont-End 2 Front-End 3 Front-End 4 E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4831A Please choose one of the front-ends: E4837A, E4838A, E4843A, E4844A, E4845A, E4846A, E4847 and write the prod ...

  • Agilent Technologies 81200 - page 15

    XI 1 23 4 5 6 7 8 9 0 10 11 12 Front-End 1 Fr ont-End 2 Front-End 3 Front-End 4 E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4831A Please choose one of the front-ends: E4837A, E4838A, E4843A, E4844A, E4845A, E4846A, E4847 and write the prod ...

  • Agilent Technologies 81200 - page 16

    Related Literature • Agilent 81200 Data Generator/Analyzer Platform, brochure • Agilent 81200 Data Generator/Analyzer Platform, data sheet specifications • Agilent E487 4A Characterization Software Components, dat a sheet • Agilent E4839A T est Fixture, dat a sheet • BestLink/81200 Simulation Data Link for the Agilent 81200 Data Generator ...

Fabricant Agilent Technologies Catégorie Laptop

Les documents que nous recevons du fabricant de l'appareilAgilent Technologies 81200 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Agilent Technologies
- manuels d’utilisations 81200
- fiches produit Agilent Technologies
- dépliants
- ou étiquettes-énergie Agilent Technologies 81200
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Agilent Technologies 81200.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Agilent Technologies 81200, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Agilent Technologies 81200. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Agilent Technologies 81200.

Manuel d’utilisation complet de l’appareil Agilent Technologies 81200, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Agilent Technologies 81200 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Agilent Technologies 81200.

Le manuel d’utilisation complet Agilent Technologies, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Agilent Technologies 81200 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Agilent Technologies 81200, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAgilent Technologies 81200 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Agilent Technologies 81200 - qui devraient nous aider dans les premières étapes lors de l'utilisation Agilent Technologies 81200
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Agilent Technologies 81200
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Agilent Technologies 81200 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Agilent Technologies 81200?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Agilent Technologies 81200, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Agilent Technologies 81200 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)