  • Weil-McLain WGO - page 1

    WGO, WTGO and SGO-W WGO, WTGO and SGO-W WGO, WTGO and SGO-W WGO, WTGO and SGO-W WGO, WTGO and SGO-W Series 3 Series 3 Series 3 Series 3 Series 3 Oil-Fir Oil-Fir Oil-Fir Oil-Fir Oil-Fir ed W ed W ed W ed W ed W ater Boilers ater Boilers ater Boilers ater Boilers ater Boilers Part No. 550-141-828/1202 Part No. 550-141-828/1202 Part No. 550-141-828/12 ...

  • Weil-McLain WGO - page 2

    2 Hazard Definitions Following terms are used to bring attention to the presence of hazards of various risk levels, or to important information concerning product life. Indicates presence of hazards that will cause severe personal injury, death or substantial property damage if ignored. Indicates presence of hazards that can cause severe personal i ...

  • Weil-McLain WGO - page 3

    3 F or Y our Saf ety Follow instructions below to prevent severe personal injury, death or substan- tial property damage: Do not use crankcase drainings or any oil containing gasoline. See burner manual for proper fuel oil. Do not attempt to start burner when excess oil has accumulated in combustion chamber, when unit is full of vapor, or when comb ...

  • Weil-McLain WGO - page 4

    4 Routine Maintenance Schedule The schedule belo w is specifically designed for the homeo wner . Please read pa ges 2 and 3 bef ore pr oceeding. Beginning each heating season: Call a qualified service technician to perform annual service. Daily during heating season: Check that boiler area is free from combusti- ble materials, gasoline and other fl ...

  • Weil-McLain WGO - page 5

    5 Star t-up WGO/WTGO (see Figure 1): 1. If burner does not fire , check for: Service switch on boiler or additional switches turned off. Fuses or breaker switch tripped. Thermostat set below room temperature. Fuel valves turned off. Not enough oil in tank to supply burner. DANGE R WGO and WTGO Boiler s Figure 1 2. Correct problems found in step #1. ...

  • Weil-McLain WGO - page 6

    6 Star t-up SGO-W Boiler Figure 2 2. Correct problems found in step #1. If burner does not fire, press reset button on burner primary control only once. Repeated presses will deposit oil in combustion chamber. Burner must never be fired when oil is in combustion chamber. Immedi- ately call qualified service technician. 3. If burner still does not f ...

  • Weil-McLain WGO - page 7

    7 The problems and corrections above represent common situations that can occur. There may be others not listed above. It is important always to contact a qualified service techni- cian if you have any questions about the operation of your boiler or system. COMMON PROBLEMS COMMON CAUSES POSSIBLE CORRECTIONS Rapid cycling - burner turns on and off f ...

  • Weil-McLain WGO - page 8

    8 The pr ocedures and inf ormation on pag es 7 thr ough 11 ar e intended only f or a qualified ser vice technician who has the necessar y equipment to inspect and adjust boiler and burner . A homeo wner should ne ver attempt these pr ocedur es. Qualified ser vice technician must r ead pa ges 2 and 3 befor e proceeding. Annual Ser vice Check List An ...

  • Weil-McLain WGO - page 9

    9 Cleaning Boiler Flueways Figure 3 Thoroughly clean flueways between all pins at all angles. Start on top of boiler, finish from the bottom. Detailed Ser vice Pr ocedur es Cleaning boiler flueways: Make sure all electrical connections to boiler are turned off and wait until boiler is warm, not hot, before cleaning. Failure to do so will result in ...

  • Weil-McLain WGO - page 10

    10 Fill the system: 1. Close manual and automatic air vents and drain cock. 2. Fill to correct system pressure. Correct pres- sure will vary with each installation. Normal cold water fill pressure for residential systems is 12 psig. Boiler water pH 7.0 to 8.5 is recom- mended. Failure to maintain recom- mended pH level can cause section failure and ...

  • Weil-McLain WGO - page 11

    11 Detailed Ser vice Pr ocedur es Controls requiring annual service: WATER RELIEF VALVE: Check operation of water relief valve. Follow instructions on label fastened to relief valve. Scald potential. Do not check operation of relief valve unless discharge piping has been installed according to Boiler Manual. If piping is not in place, a qualified s ...

  • Weil-McLain WGO - page 12

    12 Part No. 550-141-828/1202 ...

Fabricant Weil-McLain Catégorie Boiler

Les documents que nous recevons du fabricant de l'appareilWeil-McLain WGO peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Weil-McLain
- manuels d’utilisations WGO
- fiches produit Weil-McLain
- dépliants
- ou étiquettes-énergie Weil-McLain WGO
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Weil-McLain WGO.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Weil-McLain WGO, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Weil-McLain WGO. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Weil-McLain WGO.

Manuel d’utilisation complet de l’appareil Weil-McLain WGO, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Weil-McLain WGO par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Weil-McLain WGO.

Le manuel d’utilisation complet Weil-McLain, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Weil-McLain WGO - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Weil-McLain WGO, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lWeil-McLain WGO qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Weil-McLain WGO - qui devraient nous aider dans les premières étapes lors de l'utilisation Weil-McLain WGO
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Weil-McLain WGO
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Weil-McLain WGO dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Weil-McLain WGO?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Weil-McLain WGO, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Weil-McLain WGO il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)