    INSTRUCTION MANUAL MANUAL INFLA TION BLOOD PRESSURE MONITOR Model HEM-432C R ...

  • Omron Healthcare HEM-432C - page 2

    2 T ABLE OF CONTENTS Introduction …………………………………………………………… 3 Important Safety Notes ……………………………………………… 4 Know Y our Unit ……………………………………………………… 5 Quick Reference Guide ……………………………………………… 6 Bat ...

  • Omron Healthcare HEM-432C - page 3

    3 INTRODUCTION Thank you for purchasing the Omron HEM-432C Manual Inflation Blood Pressure Monitor . Fill-in for future reference DA TE PURCHASED: ______________ SERIAL NUMBER: ________________ Staple your purchase receipt here. The monitor features an easy-to-squeeze inflation bulb that allo ws you to quickly inflate the cuff. The measurement read ...

  • Omron Healthcare HEM-432C - page 4

    4 IMPORT ANT SAFETY NOTES To assur e the correct use of the pr oduct basic safety measures should always be followed including the pr ecautions listed below:  Read all information in the instruction book and any other literature included in the box before using the unit.  Contact your physician for specific information about your blood pressu ...

  • Omron Healthcare HEM-432C - page 5

    5 KNOW YOUR UNIT Systolic Blood Pressure Display ON/Off Button Air Release Button Air Inflation Bulb Air Plug Air T ube (Connects to the air plug) Air T ube Arm Cuff Diastolic Blood Pressure / Pulse rate Display Air Plug Air T ube (Connects to the air plug) MEMORY Button ...

  • Omron Healthcare HEM-432C - page 6

    6 QUICK REFERENCE GUIDE 1. Av oid eating, smoking, and exercising for at least 30 minutes before taking a measurement. 2. Put your left arm through the cuff loop. The bottom of the cuff should be about 1/2 inch abov e the elbow . The cuf f tab should lie ov er the brachial artery on the inside of the arm. 3. P ull the cuf f so that it is tightened ...

  • Omron Healthcare HEM-432C - page 7

    7 BA TTER Y INST ALLA TION / REPLACEMENT 1. Slide the battery cov er off in the direction of the arrow . 2. Install 4 “ AA” size batteries so + (positiv e) and – (negati ve) polarities match the polarities of the battery compartment as indicated. 3. Replace the battery cov er . NO TE: If the Low Battery Indicator appears on the display , repl ...

  • Omron Healthcare HEM-432C - page 8

    8 CARE AND MAINTENANCE To k eep your digital blood pressur e monitor in the best condition and pr otect the unit fr om damage follow the dir ections listed below: Clean the monitor with a soft dry cloth. Do not use any abrasi ve or v olatile cleaners. Do not attempt to clean the cuf f. Nev er immerse the monitor or any components in water . Store t ...

  • Omron Healthcare HEM-432C - page 9

    9 HOW TO APPL Y THE ARM CUFF 1. If the cuff is assembled correctly , the se wn hook material will be on the outside of the cuff loop and the metal D-ring will not touch your skin. 2. P ass the end of the cuff furthest from the tubing through the metal D-ring to form a loop. The smooth cloth should be on the inside of the cuff loop. 3. Put your left ...

  • Omron Healthcare HEM-432C - page 10

    10 HOW TO APPL Y THE ARM CUFF 4. Pull the cuff so that the top and bottom edges are tightened ev enly around your arm. 5. When the cuff is positioned correctly , press the sewn hook material FIRML Y against the pile side of the cuff. 6. Make certain the cuf f fits snugly around your arm. The cuff should mak e good contact with your skin. 7. Sit in ...

  • Omron Healthcare HEM-432C - page 11

    11 HOW TO T AKE A MEASUREMENT Please read “How T o Apply The Arm Cuff” before taking a reading. 1. Press the ON/OFF Button. a) All display symbols appear for about one second. This is the initial LCD T est. b) The display symbols disappear and the Deflation Indication Symbol ( ) starts to flash. c) When the monitor completes the necessary prepa ...

  • Omron Healthcare HEM-432C - page 12

    12 HOW TO T AKE A MEASUREMENT 3. Remain still. The cuff will begin to deflate automatically . 4. As the cuff deflates, decreasing numbers appear on the display . The Heart Symbol ( ) flashes at ev ery heartbeat. 5. When measurement is complete, the Heart Symbol ( ) stops flashing and your blood pressure and pulse rate are displayed alternately . 6. ...

  • Omron Healthcare HEM-432C - page 13

    13 HOW TO USE THE MEMOR Y FUNCTION This monitor has a memory capable of storing fourteen (14) sets of readings. E v ery time you complete the measurement, the monitor automatically stores blood pressure and pulse rate. • Press the ON/Off Button. • Press the MEMOR Y Button to recall stored readings while the Heart Symbol ( ) is displayed. • Wh ...

  • Omron Healthcare HEM-432C - page 14

    14 ERROR INDICA TORS Error Symbol Correction Cause Cuff under -inflated. Residual air pressure in cuff. Movement during Measurement No pulse or blood pressure reading due to very weak artery pulse. Cuff o ver-inflated (more than 300 mmHg). Batteries hav e run down. Press Air Release Button for 4-5 seconds to release air pressure in cuff. Carefully ...

  • Omron Healthcare HEM-432C - page 15

    15 FCC ST A TEMENT Note: PO TENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The produc ...

  • Omron Healthcare HEM-432C - page 16

    16 W ARRANTY INFORMA TION Y our HEM-432C Manual Blood Pressure Monitor , excluding the monitor cuff, is w arranted to be free from defects in materials and workmanship appearing within 1 year , when used in accordance with the instructions provided with the monitor . The monitor cuff is warranted to be free from defects in materials and workmanship ...

  • Omron Healthcare HEM-432C - page 17

    17 SPECIFICA TIONS Model: HEM-432C Display: LCD Digital Display Measurement Range: Pressure: 0 to 280 mmHg Pulse: 40-180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading Pulse: ±5% of reading Inflation: Manual by inflation bulb Deflation: Automatic pressure release valv e Rapid Air Release: Push button v alve Pressure Detection: Capac ...

  • Omron Healthcare HEM-432C - page 18

    18 NOTES ...

  • Omron Healthcare HEM-432C - page 19

    19 NOTES ...

  • Omron Healthcare HEM-432C - page 20

    Made in China Manufactured by: OMR ON HEAL THCARE, INC. 300 Lake view Parkw ay V ernon Hills, Illinois 60061 www .omronhealthcare.com Copyright © 2003 Omron Healthcare, Inc. 432CINST Rev A ...

Fabricant Omron Healthcare Catégorie Blood Pressure Monitor

Les documents que nous recevons du fabricant de l'appareilOmron Healthcare HEM-432C peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Omron Healthcare
- manuels d’utilisations HEM-432C
- fiches produit Omron Healthcare
- dépliants
- ou étiquettes-énergie Omron Healthcare HEM-432C
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Omron Healthcare HEM-432C.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Omron Healthcare HEM-432C, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Omron Healthcare HEM-432C. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Omron Healthcare HEM-432C.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Omron Healthcare HEM-432C, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Omron Healthcare HEM-432C par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Omron Healthcare HEM-432C.

Le manuel d’utilisation complet Omron Healthcare, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Omron Healthcare HEM-432C - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Omron Healthcare HEM-432C, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lOmron Healthcare HEM-432C qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Omron Healthcare HEM-432C - qui devraient nous aider dans les premières étapes lors de l'utilisation Omron Healthcare HEM-432C
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Omron Healthcare HEM-432C
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Omron Healthcare HEM-432C dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Omron Healthcare HEM-432C?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Omron Healthcare HEM-432C, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Omron Healthcare HEM-432C il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)