Manual Omron Healthcare HEM-432C

20 pages 0.22 mb
Download

Go to site of 20

Summary
  • Omron Healthcare HEM-432C - page 1

    INSTRUCTION MANUAL MANUAL INFLA TION BLOOD PRESSURE MONITOR Model HEM-432C R ...

  • Omron Healthcare HEM-432C - page 2

    2 T ABLE OF CONTENTS Introduction …………………………………………………………… 3 Important Safety Notes ……………………………………………… 4 Know Y our Unit ……………………………………………………… 5 Quick Reference Guide ……………………………………………… 6 Bat ...

  • Omron Healthcare HEM-432C - page 3

    3 INTRODUCTION Thank you for purchasing the Omron HEM-432C Manual Inflation Blood Pressure Monitor . Fill-in for future reference DA TE PURCHASED: ______________ SERIAL NUMBER: ________________ Staple your purchase receipt here. The monitor features an easy-to-squeeze inflation bulb that allo ws you to quickly inflate the cuff. The measurement read ...

  • Omron Healthcare HEM-432C - page 4

    4 IMPORT ANT SAFETY NOTES To assur e the correct use of the pr oduct basic safety measures should always be followed including the pr ecautions listed below:  Read all information in the instruction book and any other literature included in the box before using the unit.  Contact your physician for specific information about your blood pressu ...

  • Omron Healthcare HEM-432C - page 5

    5 KNOW YOUR UNIT Systolic Blood Pressure Display ON/Off Button Air Release Button Air Inflation Bulb Air Plug Air T ube (Connects to the air plug) Air T ube Arm Cuff Diastolic Blood Pressure / Pulse rate Display Air Plug Air T ube (Connects to the air plug) MEMORY Button ...

  • Omron Healthcare HEM-432C - page 6

    6 QUICK REFERENCE GUIDE 1. Av oid eating, smoking, and exercising for at least 30 minutes before taking a measurement. 2. Put your left arm through the cuff loop. The bottom of the cuff should be about 1/2 inch abov e the elbow . The cuf f tab should lie ov er the brachial artery on the inside of the arm. 3. P ull the cuf f so that it is tightened ...

  • Omron Healthcare HEM-432C - page 7

    7 BA TTER Y INST ALLA TION / REPLACEMENT 1. Slide the battery cov er off in the direction of the arrow . 2. Install 4 “ AA” size batteries so + (positiv e) and – (negati ve) polarities match the polarities of the battery compartment as indicated. 3. Replace the battery cov er . NO TE: If the Low Battery Indicator appears on the display , repl ...

  • Omron Healthcare HEM-432C - page 8

    8 CARE AND MAINTENANCE To k eep your digital blood pressur e monitor in the best condition and pr otect the unit fr om damage follow the dir ections listed below: Clean the monitor with a soft dry cloth. Do not use any abrasi ve or v olatile cleaners. Do not attempt to clean the cuf f. Nev er immerse the monitor or any components in water . Store t ...

  • Omron Healthcare HEM-432C - page 9

    9 HOW TO APPL Y THE ARM CUFF 1. If the cuff is assembled correctly , the se wn hook material will be on the outside of the cuff loop and the metal D-ring will not touch your skin. 2. P ass the end of the cuff furthest from the tubing through the metal D-ring to form a loop. The smooth cloth should be on the inside of the cuff loop. 3. Put your left ...

  • Omron Healthcare HEM-432C - page 10

    10 HOW TO APPL Y THE ARM CUFF 4. Pull the cuff so that the top and bottom edges are tightened ev enly around your arm. 5. When the cuff is positioned correctly , press the sewn hook material FIRML Y against the pile side of the cuff. 6. Make certain the cuf f fits snugly around your arm. The cuff should mak e good contact with your skin. 7. Sit in ...

  • Omron Healthcare HEM-432C - page 11

    11 HOW TO T AKE A MEASUREMENT Please read “How T o Apply The Arm Cuff” before taking a reading. 1. Press the ON/OFF Button. a) All display symbols appear for about one second. This is the initial LCD T est. b) The display symbols disappear and the Deflation Indication Symbol ( ) starts to flash. c) When the monitor completes the necessary prepa ...

  • Omron Healthcare HEM-432C - page 12

    12 HOW TO T AKE A MEASUREMENT 3. Remain still. The cuff will begin to deflate automatically . 4. As the cuff deflates, decreasing numbers appear on the display . The Heart Symbol ( ) flashes at ev ery heartbeat. 5. When measurement is complete, the Heart Symbol ( ) stops flashing and your blood pressure and pulse rate are displayed alternately . 6. ...

  • Omron Healthcare HEM-432C - page 13

    13 HOW TO USE THE MEMOR Y FUNCTION This monitor has a memory capable of storing fourteen (14) sets of readings. E v ery time you complete the measurement, the monitor automatically stores blood pressure and pulse rate. • Press the ON/Off Button. • Press the MEMOR Y Button to recall stored readings while the Heart Symbol ( ) is displayed. • Wh ...

  • Omron Healthcare HEM-432C - page 14

    14 ERROR INDICA TORS Error Symbol Correction Cause Cuff under -inflated. Residual air pressure in cuff. Movement during Measurement No pulse or blood pressure reading due to very weak artery pulse. Cuff o ver-inflated (more than 300 mmHg). Batteries hav e run down. Press Air Release Button for 4-5 seconds to release air pressure in cuff. Carefully ...

  • Omron Healthcare HEM-432C - page 15

    15 FCC ST A TEMENT Note: PO TENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The produc ...

  • Omron Healthcare HEM-432C - page 16

    16 W ARRANTY INFORMA TION Y our HEM-432C Manual Blood Pressure Monitor , excluding the monitor cuff, is w arranted to be free from defects in materials and workmanship appearing within 1 year , when used in accordance with the instructions provided with the monitor . The monitor cuff is warranted to be free from defects in materials and workmanship ...

  • Omron Healthcare HEM-432C - page 17

    17 SPECIFICA TIONS Model: HEM-432C Display: LCD Digital Display Measurement Range: Pressure: 0 to 280 mmHg Pulse: 40-180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading Pulse: ±5% of reading Inflation: Manual by inflation bulb Deflation: Automatic pressure release valv e Rapid Air Release: Push button v alve Pressure Detection: Capac ...

  • Omron Healthcare HEM-432C - page 18

    18 NOTES ...

  • Omron Healthcare HEM-432C - page 19

    19 NOTES ...

  • Omron Healthcare HEM-432C - page 20

    Made in China Manufactured by: OMR ON HEAL THCARE, INC. 300 Lake view Parkw ay V ernon Hills, Illinois 60061 www .omronhealthcare.com Copyright © 2003 Omron Healthcare, Inc. 432CINST Rev A ...

Manufacturer Omron Healthcare Category Blood Pressure Monitor

Documents that we receive from a manufacturer of a Omron Healthcare HEM-432C can be divided into several groups. They are, among others:
- Omron Healthcare technical drawings
- HEM-432C manuals
- Omron Healthcare product data sheets
- information booklets
- or energy labels Omron Healthcare HEM-432C
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omron Healthcare HEM-432C.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omron Healthcare HEM-432C, service manual, brief instructions and user manuals Omron Healthcare HEM-432C. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omron Healthcare HEM-432C.

A complete manual for the device Omron Healthcare HEM-432C, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omron Healthcare HEM-432C by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omron Healthcare HEM-432C.

A complete Omron Healthcare manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omron Healthcare HEM-432C - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omron Healthcare HEM-432C, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omron Healthcare HEM-432C, that we can find in the current document
3. Tips how to use the basic functions of the device Omron Healthcare HEM-432C - which should help us in our first steps of using Omron Healthcare HEM-432C
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omron Healthcare HEM-432C
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omron Healthcare HEM-432C in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omron Healthcare HEM-432C?

Use the form below

If you did not solve your problem by using a manual Omron Healthcare HEM-432C, ask a question using the form below. If a user had a similar problem with Omron Healthcare HEM-432C it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)