Manuel d’utilisation Napoleon Fireplaces GD70PT-S

28 pages 1.96 mb
Télécharger

Aller à la page of 28

Summary
  • Napoleon Fireplaces GD70PT-S - page 1

    1 W415-0434 / C / 03.24.05 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.ca VENTED GAS FIREPLACE HEA TER DIRECT VENT MILLIVOL T SYSTEM INST ALLA TION AND OPERA TION IN ...

  • Napoleon Fireplaces GD70PT-S - page 2

    2 W415-0434 / C / 03.24.05 PG 2-5 INTRODUCTION Warranty Dimensions General Instructions General Information Care of Glass & Plated Parts 5-10 V E N T I N G V ent lengths V enting S pecifications Air T erminal Locations 1 1 -1 5 IN ST ALLA TION/FRAMING Wall & Ceiling Protection Using Flexible V ent Components Fireplace V ent Connection Using ...

  • Napoleon Fireplaces GD70PT-S - page 3

    3 W415-0434 / C / 03.24.05 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT T O CHANGE WITHOUT PRIOR NOTICE DUE T O ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. PA TENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.915. © WOLF STEEL L TD. NAPOLEON gas fireplaces are manufactured under the strict Standard of the ...

  • Napoleon Fireplaces GD70PT-S - page 4

    4 W415-0434 / C / 03.24.05 Purge all gas lines with the glass door of the fireplace op e n . Assure that a continuous gas flow is at the burner before cl o s i ng the door . Under extreme vent configurations, allow several minutes (5-15) for the flame to stabilize after ignition. Eight (8") inches is the minimum bend radius allowed for the 7&q ...

  • Napoleon Fireplaces GD70PT-S - page 5

    5 W415-0434 / C / 03.24.05 Do not use abrasive cleaners to clean plated parts. Buff lightly with a clean dry cloth. The glass is 3/16" ceramic glass available from your Napoleon / Wolf S teel Ltd. dealer . DO NOT SUBSTITUTE MA TERIALS. Clean the glass af ter the first 10 hours of operation with a recommended gas fireplace glass cleaner . There ...

  • Napoleon Fireplaces GD70PT-S - page 6

    6 W415-0434 / C / 03.24.05 when (H T ) < (V T ) Simple venting configuration (only one 90° elbow) VERTICAL RISE IN FEET V T FIGURE 4 See graph to determine the required vertical rise V T for the required horizontal run H T . For vent configurations requiring more than one 90° el- bow , the following formulas apply: F or mula 1: H T < V T F ...

  • Napoleon Fireplaces GD70PT-S - page 7

    7 W415-0434 / C / 03.24.05 H 2 H 1 V 1 90° See graph to determine the required ver- tical rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 =3 f t H 2 =5 f t H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .03(two 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft H T = H R + H O = 8 + 2.7 = 10.7 ft H T + V T = 10.7 + 6 =16.7 Formula 1: H T & ...

  • Napoleon Fireplaces GD70PT-S - page 8

    8 W415-0434 / C / 03.24.05 REQUIRED VERTICAL RISE IN F E E T V T HOR IZON T AL VENT RUN PLUS OFFSET IN FEET H T The shaded area within the lines represents acceptable values for H T and V T . when (H T ) < (V T ) Simple venting configurations FIGURE 9 For vent configurations requiring more than zero 90° elbow (top exit) or one 90° elbow (rear ...

  • Napoleon Fireplaces GD70PT-S - page 9

    9 W415-0434 / C / 03.24.05 0 51 0 1 5 2 0 10 20 3 25 30 19 MAXIMUM VERTICAL RISE IN FEET V T HO RIZ O N T AL VENT RUN PLUS OFFSET IN FE E T T The shaded area within the lines represents acceptable values for H T and V T . See graph to determine the required vertical rise V T for the required horizontal run H T . V 1 =2 f t V 2 =1 f t V 3 =1 . 5 f t ...

  • Napoleon Fireplaces GD70PT-S - page 10

    10 W415-0434 / C / 03.24.05 AIR TERMINAL INST ALLA TIONS * * * Recommended to prevent condensation on windows and thermal breakage * * * * * * * * * * It is recommended to use a hea t shie ld and to maximize the distance to vinyl clad soffits. *** *** *** *** ** * The periscope GD-201 r equires a minimum 18 inche s c learance fr om an inside corner ...

  • Napoleon Fireplaces GD70PT-S - page 11

    11 W415-0434 / C / 03.24.05 FIGURE 14 OR This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Na- poleon dealer . See Ac- cessories to order the specific kit required. 1. Determine the air ter- minal location, cut and frame 9½ inch open- ings in the ceiling and the roof to provide ...

  • Napoleon Fireplaces GD70PT-S - page 12

    12 W415-0434 / C / 03.24.05 FIGURE 20 Use only approved aluminum flexible liner kits marked " Wo lf Steel Appr oved V enting" as identified by the stamp only on the 7" outer liner . For optimum performance it is recommended that all horizontal runs have a minimum ¼ inch rise per foot using flexible venting. 1. S tretch the 4" d ...

  • Napoleon Fireplaces GD70PT-S - page 13

    13 W415-0434 / C / 03.24.05 FIGURE 23 1. Move the fireplace into position. 2. Fasten the roof support to the roof using the screws provided. FIGURE 16. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having ju- risdiction or the optional roof sup- port. ...

  • Napoleon Fireplaces GD70PT-S - page 14

    14 W415-0434 / C / 03.24.05 * * * * * When using the optional ornamental facia and panels, the minimum height from the top of the unit to the mantle is 7". ** A steel stud header is recommended, however tradi- tional combustible header material may be used. TILES GD425 BLACK P AINTED FIREPLACE SURF ACE Tiles must not pro- trude past the inner ...

  • Napoleon Fireplaces GD70PT-S - page 15

    15 W415-0434 / C / 03.24.05 Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clear- ance needed. FIGURE 37 MANTLE CLEARANCES ** EXAMPLE A - NON-COMB USTIBLE MA TERIAL It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4's and frame to local bu ...

  • Napoleon Fireplaces GD70PT-S - page 16

    16 W415-0434 / C / 03.24.05 Open the valve control door. Hook the top and bottom door latches, located at the right side of the door into the corre- sponding slots in the door. The do or lat ch hol es are el onga ted for door level lin g. To level the door, i t may need to be lifte d up at the right side before latc hing to ensure the door is level ...

  • Napoleon Fireplaces GD70PT-S - page 17

    17 W415-0434 / C / 03.24.05 A C B L38 LOUVRE INST ALLA TION FIGURE 43 a-c HOOD Attach the hood by pressing the top flange into the clips along the top of the louvre opening. Secure using a screw through the centre slot. LOWER LOUVRES Insert the hinge clips into the slots located at the bottom left and right corners of the unit. T o remove the louvr ...

  • Napoleon Fireplaces GD70PT-S - page 18

    18 W415-0434 / C / 03.24.05 Glowing embers (not supplied) maybe used to enhance the flame's appearance. 4. Place log #4, with the charred branch pointed inward. Locate the pins into the holes in log#1 and log#2, this will hold the rear log in position. 5. Place the end of log #5 on the right end of log #1. The fork in the log should straddle t ...

  • Napoleon Fireplaces GD70PT-S - page 19

    19 W415-0434 / C / 03.24.05 The FIRE LOG ACCENT LIGHT is provided with a manual "in- line" switch to turn the light on and off. There are alternate meth- ods of operating the light. An example of one method would be to "hard-wire" a wall switch. The switch could be installed in desired location to operate the FIRE LOG ACCENT LIG ...

  • Napoleon Fireplaces GD70PT-S - page 20

    20 W415-0434 / C / 03.24.05 BL OWER INST ALLA TION FIGURE 51 The Napoleon ST ARfire comes equipped with a blower , a heat sensor , variable on/off speed control and a power cord. The blower is thermally activated, so when it is turned on, it will automatically start approximately 15 minutes after light- ing the fireplace and will run for approximat ...

  • Napoleon Fireplaces GD70PT-S - page 21

    21 W415-0434 / C / 03.24.05 A. This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly . B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor . C. Use only your hand to turn the gas control knob. Ne ...

  • Napoleon Fireplaces GD70PT-S - page 22

    22 W415-0434 / C / 03.24.05 Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be estab- lished. AIR SHUTTER ADJUST ...

  • Napoleon Fireplaces GD70PT-S - page 23

    23 W415-0434 / C / 03.24.05 # P A RT NO . DESCRIPTION 1 W135-0205 # 1 - R EA R L OG 2 W135-0206 # 2 - M I DDLE LOG 3 W135-0207 # 3 - RIG HT LO G 4 W135-0208 # 4 - LEF T L OG 5 W135-0218 # 5 - C RO SS OV ER L OG 6 GL- 644 LOG SET ASSEMBL Y 7* W090-0095 L CH AR CO AL S TR IP 8* W090-0096 R CH AR CO AL S TR IP 9* W390-0002 DOO R L A TCH ( EA ) 1 0 W72 ...

  • Napoleon Fireplaces GD70PT-S - page 24

    24 W415-0434 / C / 03.24.05 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf S teel Ltd. ...

  • Napoleon Fireplaces GD70PT-S - page 25

    25 W415-0434 / C / 03.24.05 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a gas fireplace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned of f regularly , the glass may become permanently marked. Carbon is being deposited on glass, logs ...

  • Napoleon Fireplaces GD70PT-S - page 26

    26 W415-0434 / C / 03.24.05 Remote wall switch is in "OFF" position; main burner comes on when gas knob is turned to "ON" po- sition. Wall switch is mounted up- side down - reverse. Faulty valve. - replace. - replace. Remote wall switch is grounding. - check for ground (short); repair ground or replace wire. Remote wall switch w ...

  • Napoleon Fireplaces GD70PT-S - page 27

    27 W415-0434 / C / 03.24.05 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer Name ...

  • Napoleon Fireplaces GD70PT-S - page 28

    28 W415-0434 / C / 03.24.05 NO TES ...

Fabricant Napoleon Fireplaces Catégorie Electric Heater

Les documents que nous recevons du fabricant de l'appareilNapoleon Fireplaces GD70PT-S peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Napoleon Fireplaces
- manuels d’utilisations GD70PT-S
- fiches produit Napoleon Fireplaces
- dépliants
- ou étiquettes-énergie Napoleon Fireplaces GD70PT-S
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Napoleon Fireplaces GD70PT-S.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Napoleon Fireplaces GD70PT-S, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Napoleon Fireplaces GD70PT-S. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Napoleon Fireplaces GD70PT-S.

Manuel d’utilisation complet de l’appareil Napoleon Fireplaces GD70PT-S, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Napoleon Fireplaces GD70PT-S par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Napoleon Fireplaces GD70PT-S.

Le manuel d’utilisation complet Napoleon Fireplaces, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Napoleon Fireplaces GD70PT-S - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Napoleon Fireplaces GD70PT-S, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lNapoleon Fireplaces GD70PT-S qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Napoleon Fireplaces GD70PT-S - qui devraient nous aider dans les premières étapes lors de l'utilisation Napoleon Fireplaces GD70PT-S
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Napoleon Fireplaces GD70PT-S
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Napoleon Fireplaces GD70PT-S dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Napoleon Fireplaces GD70PT-S?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Napoleon Fireplaces GD70PT-S, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Napoleon Fireplaces GD70PT-S il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)