    FMA 3200/3200ST/ 3400/3400ST Series Thermal Mass Flo w Controllers ...

  • Omega 3200 - page 2

    ...

  • Omega 3200 - page 3

    M-4271/0707 , pg. 3 of 26 READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSO R. FAILURE TO DO SO MAY RESULT I N INJURY TO YOU OR DAMAGE TO THE FLO W CONTROLL ER. TABLE OF CONT ENTS A. I ntr o du ct io n ...................... ............... ............... ............... ............... ........... 4 1. U np a cki ...

  • Omega 3200 - page 4

    M-4271/0707 , pg. 4 of 26 A. Introduction 1. Un pa cking All units ar e suitably p a ck a g ed to prev ent damage d urin g s hipping. I f e xterna l da m ag e is no ted u pon rece ipt of the packag e, pl ease c ontact Omega Engineering immediatel y. Open the p a ck age from t he top, t aking care not to cut too d eeply into t h e package. Remo ve a ...

  • Omega 3200 - page 5

    M-4271/0707 , pg. 5 of 26 sensor d e si gn. T his proven d esign minimizes z e ro dr ift w h il e maintai n in g fast r espons e and li near o utputs with v irtu a ll y no mainte nanc e . The FMA 3 200/3400 Series u tilize s therma l flow sensing technology. A portio n o f the gas flowi n g t hrough the unit is redirect ed in t o a sm all sensor tu ...

  • Omega 3200 - page 6

    M-4271/0707 , pg. 6 of 26 un it ma y be da mage d or fa il pr ema t u rel y. Such dama ge w ill no t be repaired un der warranty. Un i ts sh ou ld be in st a lle d in a c lea n, d r y en vi ron me n t w it h a n a mb ie nt te mp er at ure t h at i s as st ab le as p os si ble. Av oi d ar e as wit h s tro ng mag ne ti c fi el ds , st ro ng air f lo ...

  • Omega 3200 - page 7

    M-4271/0707 , pg. 7 of 26 2. Mounting the Fl ow Controller. The F MA 320 0/34 00 Series control lers hav e no p articul ar ori entati on o r in stal latio n re quire ments s o may be moun ted in any c onve nien t posi tion. It i s re commen ded tha t un its be fixed to a su itable subs trate usin g the two 4-40 mounting holes provided. Mountin g Vi ...

  • Omega 3200 - page 8

    M-4271/0707 , pg. 8 of 26 4. El e ct ri cal C on ne ction s Cauti o n: I ncorr e ct wir ing may caus e seve re dam a g e to t he unit . Applying an AC vo ltage (11 5VAC or 23 0VAC) directly to the un it will cau se dama ge. Re ad the follow ing instru cti ons care fu lly before m akin g any connections. a) Overview The FMA 3200/34 0 0 Series provid ...

  • Omega 3200 - page 9

    M-4271/0707 , pg. 9 of 26 b) Conne c ting The 6 P i n Mini D in Conne ctor Using a s u itabl e mating co nnector the pins of t he i n tegrat e d connect or sho u ld b e wir ed as foll ows: Connecti ng To The Inte grate d 6 Pi n Connecto r Pin 2 should be connect ed to the Positive of th e power sourc e . Pin 6 should be connected to the Negative (G ...

  • Omega 3200 - page 10

    M-4271/07 07, pg. 10 o f 26 c) Connecting The 6 Pin M ini Din Connector & FMA 3000C Cable Th e two m at in g co nne cto rs sho uld be p ush ed to get her and th e pi gta il leads wired as foll ows: Connecting To The Integrated 6 Pi n C onnector Using A FMA 3000C Ca b le The RED wire should be conn ected to th e Posi tive of the power s ource . ...

  • Omega 3200 - page 11

    M-4271/07 07, pg. 11 o f 26 d) Conne ctions F or The 9 P in D Sub C onnect o r Using a s u itabl e mating co nnector the pins of t he i n tegrat e d connect or sho u ld b e wir ed as foll ows: Connecti ng To The Inte grate d 9 Pi n Connecto r PIN 3 sh ould be connec te d to the Po sitive of the powe r sou rce. PIN 4 sh oul d be connec te d to the N ...

  • Omega 3200 - page 12

    M-4271/07 07, pg. 12 o f 26 e) Conne ctio ns For T he 15 D Sub Conne ctor Using a s u itabl e mating co nnector the pins of t he i n tegrat e d connect or sho u ld b e wir ed as foll ows: Connecti ng To The Integr ated 15 Pin Connec tor PIN 7 sh ould be connec te d to the Po sitive of the powe r sou rce. PIN 5 sh oul d be connec te d to the Ne gati ...

  • Omega 3200 - page 13

    M-4271/07 07, pg. 13 o f 26 f) Usin g a 0-5V DC I nput / Output Power A d a p ter Pa c ka g e . An optional 0-5VDC I nput / Output Power Ad a pter P a ck a ge is a v a il able for use with t he FM A 3 200/3 400 S e ri es. Thi s co nsists of a po wer so urc e (115VAC o r 2 30VAC), a connection hub a n d two c able assemblies wi th pig- tail (sold er ...

  • Omega 3200 - page 14

    M-4271/07 07, pg. 14 o f 26 C. Operation 1. Warm U p Before ap plying power to the un it che ck a ll t ubing a nd electric a l connections. On ce corr e ct inst a llat ion is verifi e d switch o n t he pow e r. T he unit sho uld then b e allowe d to warm up for 5 min utes be fore gas pr essur e is appli ed. 2. Ve ri fi c a t i on o f Ze r o Flow th ...

  • Omega 3200 - page 15

    M-4271/07 07, pg. 15 o f 26 Q 1 / Q 2 = K 1 / K 2 Q 1 is the flow rate of the new g as Q 2 is th e flow ra te of the orig ina l calibra tion gas K 1 is the K factor of th e new g a s K 2 is the K factor of t he original c alibra t ion gas Q 1 = (K 1 / K 2 ) Q 2 If K 2 is larger than K 1 t hen li ne ar r es ult s wi l l onl y b e a chi ev ed i f th ...

  • Omega 3200 - page 16

    M-4271/07 07, pg. 16 o f 26 If a ga s o the r tha n th e ca l ib ra t ion g a s is u se d the n the a dj us te d m axi mu m (full scal e ) f low f or t he unit sho uld be c a lcul ated using t he K F a ctor for that gas (s ee s e ctio n C3 abov e). A zero or negative set- po int voltage wil l cause t he solenoi d valve to c lose fully. Whilst cl os ...

  • Omega 3200 - page 17

    M-4271/07 07, pg. 17 o f 26 7. Zer o Adjustm ents The zero should be checked as d etailed in section C part 2 . If an adjustm ent is needed the Z e ro Pot entiomet er should be carefull y tur ned until the output (VDC) b e com es zero . Cauti o n: Do NOT ad just the Gain P otenti omete r when adjus ting th e zero or the unit w ill n eed to be re ca ...

  • Omega 3200 - page 18

    M-4271/07 07, pg. 18 o f 26 FMA 3400/3400ST Series Dip Switches Dip swit ch 4 is allo ca t ed to the pri m ary c a lib ration gas. Dip swit ch 5 is alloc a te d to the second c a libr ation gas (i f a p plic able). Dip switch 6 is a llo ca t ed to the t hird calibration g a s (i f app lica bl e). To select th e gas, the dip s witch should b e turn ...

  • Omega 3200 - page 19

    M-4271/07 07, pg. 19 o f 26 E. Specific ations Series FMA 3200 FMA 3400 FMA 3200ST FMA 3400ST Ac cur a cy (including linearity) ±1.5% of Full Scal e* ±1. 5% o f Full Sc ale* Second and third gases ±3. 0% F .S. * ±1.5 % o f Full Sc ale* ±1.5 % of Full Sc ale* Second and thi rd ga ses ±3.0 % F. S .* Repeatability ±0.25% Full Scale* Pressure Ra ...

  • Omega 3200 - page 20

    M-4271/07 07, pg. 20 o f 26 F. Dimensions ALL DIMEN SIONS IN INCHE S (MIL LIMETERS IN BRAC KETS) FMA 3200/3200ST Series - 1/4 ” Stainl ess Fittings Shown ...

  • Omega 3200 - page 21

    M-4271/07 07, pg. 21 o f 26 FMA 3400/3400ST Series - 1/4 ” Stainl ess Fittings Shown ...

  • Omega 3200 - page 22

    M-4271/07 07, pg. 22 o f 26 G. Gas K Facto rs Gas Chemical Symbo l K Fa ct or Ace tylene C 2 H 2 0.58 9 Air - 1.00 0 Argon Ar 1.438 Butane C 4 H 10 0.2 60 Ca rbon D io xide CO 2 0.73 9 Deu teriu m D 2 1.00 0 Ethyl ene C 2 H 4 0.59 8 Freon 11 CCL 3 F 0.3 30 Freon 12 CCL 2 F 2 0.3 54 Freon 13 CCLF 3 0.38 5 Freon 14 CF 4 0.42 0 Freon 22 CHCLF 2 0.46 0 ...

  • Omega 3200 - page 23

    M-4271/07 07, pg. 23 o f 26 H. Troubleshooting Guide Symptom Poss ible Cau s e Method of Correction Clicking no ise from controlle r Unit i n error mode C heck there is suff icien t pres s ure and that th e f low path i s not restric ted or blocke d Unit wired incorrectly Check wiring is accordin g to Section B5 Loo se co nnectio n Check all c onne ...

  • Omega 3200 - page 24

    M-4271/07 07, pg. 24 o f 26 Symptom Poss ible Cau s e Method of Correction Insuf ficient or vary ing power Check the power supply ou tp ut a nd inc reas e i f necessary Insuf ficient pr essure En sur e the pres sure (an diffe r en tial pressu re) is high enou gh o op erat e the uni t. Varyin g pr essure Check the s tabi lity of the pressure regulat ...

  • Omega 3200 - page 25

    M-4271/07 07, pg. 25 o f 26 . ...

  • Omega 3200 - page 26

    M-4271/07 07, pg. 26 o f 26 ...

Fabricant Omega Catégorie Binding Machine

Les documents que nous recevons du fabricant de l'appareilOmega 3200 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Omega
- manuels d’utilisations 3200
- fiches produit Omega
- dépliants
- ou étiquettes-énergie Omega 3200
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Omega 3200.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Omega 3200, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Omega 3200. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Omega 3200.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Omega 3200, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Omega 3200 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Omega 3200.

Le manuel d’utilisation complet Omega, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Omega 3200 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Omega 3200, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lOmega 3200 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Omega 3200 - qui devraient nous aider dans les premières étapes lors de l'utilisation Omega 3200
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Omega 3200
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Omega 3200 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Omega 3200?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Omega 3200, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Omega 3200 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)