Omega 3200の取扱説明書

26ページ 0.81 mb
ダウンロード

ページに移動 of 26

Summary
  • Omega 3200 - page 1

    FMA 3200/3200ST/ 3400/3400ST Series Thermal Mass Flo w Controllers ...

  • Omega 3200 - page 2

    ...

  • Omega 3200 - page 3

    M-4271/0707 , pg. 3 of 26 READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSO R. FAILURE TO DO SO MAY RESULT I N INJURY TO YOU OR DAMAGE TO THE FLO W CONTROLL ER. TABLE OF CONT ENTS A. I ntr o du ct io n ...................... ............... ............... ............... ............... ........... 4 1. U np a cki ...

  • Omega 3200 - page 4

    M-4271/0707 , pg. 4 of 26 A. Introduction 1. Un pa cking All units ar e suitably p a ck a g ed to prev ent damage d urin g s hipping. I f e xterna l da m ag e is no ted u pon rece ipt of the packag e, pl ease c ontact Omega Engineering immediatel y. Open the p a ck age from t he top, t aking care not to cut too d eeply into t h e package. Remo ve a ...

  • Omega 3200 - page 5

    M-4271/0707 , pg. 5 of 26 sensor d e si gn. T his proven d esign minimizes z e ro dr ift w h il e maintai n in g fast r espons e and li near o utputs with v irtu a ll y no mainte nanc e . The FMA 3 200/3400 Series u tilize s therma l flow sensing technology. A portio n o f the gas flowi n g t hrough the unit is redirect ed in t o a sm all sensor tu ...

  • Omega 3200 - page 6

    M-4271/0707 , pg. 6 of 26 un it ma y be da mage d or fa il pr ema t u rel y. Such dama ge w ill no t be repaired un der warranty. Un i ts sh ou ld be in st a lle d in a c lea n, d r y en vi ron me n t w it h a n a mb ie nt te mp er at ure t h at i s as st ab le as p os si ble. Av oi d ar e as wit h s tro ng mag ne ti c fi el ds , st ro ng air f lo ...

  • Omega 3200 - page 7

    M-4271/0707 , pg. 7 of 26 2. Mounting the Fl ow Controller. The F MA 320 0/34 00 Series control lers hav e no p articul ar ori entati on o r in stal latio n re quire ments s o may be moun ted in any c onve nien t posi tion. It i s re commen ded tha t un its be fixed to a su itable subs trate usin g the two 4-40 mounting holes provided. Mountin g Vi ...

  • Omega 3200 - page 8

    M-4271/0707 , pg. 8 of 26 4. El e ct ri cal C on ne ction s Cauti o n: I ncorr e ct wir ing may caus e seve re dam a g e to t he unit . Applying an AC vo ltage (11 5VAC or 23 0VAC) directly to the un it will cau se dama ge. Re ad the follow ing instru cti ons care fu lly before m akin g any connections. a) Overview The FMA 3200/34 0 0 Series provid ...

  • Omega 3200 - page 9

    M-4271/0707 , pg. 9 of 26 b) Conne c ting The 6 P i n Mini D in Conne ctor Using a s u itabl e mating co nnector the pins of t he i n tegrat e d connect or sho u ld b e wir ed as foll ows: Connecti ng To The Inte grate d 6 Pi n Connecto r Pin 2 should be connect ed to the Positive of th e power sourc e . Pin 6 should be connected to the Negative (G ...

  • Omega 3200 - page 10

    M-4271/07 07, pg. 10 o f 26 c) Connecting The 6 Pin M ini Din Connector & FMA 3000C Cable Th e two m at in g co nne cto rs sho uld be p ush ed to get her and th e pi gta il leads wired as foll ows: Connecting To The Integrated 6 Pi n C onnector Using A FMA 3000C Ca b le The RED wire should be conn ected to th e Posi tive of the power s ource . ...

  • Omega 3200 - page 11

    M-4271/07 07, pg. 11 o f 26 d) Conne ctions F or The 9 P in D Sub C onnect o r Using a s u itabl e mating co nnector the pins of t he i n tegrat e d connect or sho u ld b e wir ed as foll ows: Connecti ng To The Inte grate d 9 Pi n Connecto r PIN 3 sh ould be connec te d to the Po sitive of the powe r sou rce. PIN 4 sh oul d be connec te d to the N ...

  • Omega 3200 - page 12

    M-4271/07 07, pg. 12 o f 26 e) Conne ctio ns For T he 15 D Sub Conne ctor Using a s u itabl e mating co nnector the pins of t he i n tegrat e d connect or sho u ld b e wir ed as foll ows: Connecti ng To The Integr ated 15 Pin Connec tor PIN 7 sh ould be connec te d to the Po sitive of the powe r sou rce. PIN 5 sh oul d be connec te d to the Ne gati ...

  • Omega 3200 - page 13

    M-4271/07 07, pg. 13 o f 26 f) Usin g a 0-5V DC I nput / Output Power A d a p ter Pa c ka g e . An optional 0-5VDC I nput / Output Power Ad a pter P a ck a ge is a v a il able for use with t he FM A 3 200/3 400 S e ri es. Thi s co nsists of a po wer so urc e (115VAC o r 2 30VAC), a connection hub a n d two c able assemblies wi th pig- tail (sold er ...

  • Omega 3200 - page 14

    M-4271/07 07, pg. 14 o f 26 C. Operation 1. Warm U p Before ap plying power to the un it che ck a ll t ubing a nd electric a l connections. On ce corr e ct inst a llat ion is verifi e d switch o n t he pow e r. T he unit sho uld then b e allowe d to warm up for 5 min utes be fore gas pr essur e is appli ed. 2. Ve ri fi c a t i on o f Ze r o Flow th ...

  • Omega 3200 - page 15

    M-4271/07 07, pg. 15 o f 26 Q 1 / Q 2 = K 1 / K 2 Q 1 is the flow rate of the new g as Q 2 is th e flow ra te of the orig ina l calibra tion gas K 1 is the K factor of th e new g a s K 2 is the K factor of t he original c alibra t ion gas Q 1 = (K 1 / K 2 ) Q 2 If K 2 is larger than K 1 t hen li ne ar r es ult s wi l l onl y b e a chi ev ed i f th ...

  • Omega 3200 - page 16

    M-4271/07 07, pg. 16 o f 26 If a ga s o the r tha n th e ca l ib ra t ion g a s is u se d the n the a dj us te d m axi mu m (full scal e ) f low f or t he unit sho uld be c a lcul ated using t he K F a ctor for that gas (s ee s e ctio n C3 abov e). A zero or negative set- po int voltage wil l cause t he solenoi d valve to c lose fully. Whilst cl os ...

  • Omega 3200 - page 17

    M-4271/07 07, pg. 17 o f 26 7. Zer o Adjustm ents The zero should be checked as d etailed in section C part 2 . If an adjustm ent is needed the Z e ro Pot entiomet er should be carefull y tur ned until the output (VDC) b e com es zero . Cauti o n: Do NOT ad just the Gain P otenti omete r when adjus ting th e zero or the unit w ill n eed to be re ca ...

  • Omega 3200 - page 18

    M-4271/07 07, pg. 18 o f 26 FMA 3400/3400ST Series Dip Switches Dip swit ch 4 is allo ca t ed to the pri m ary c a lib ration gas. Dip swit ch 5 is alloc a te d to the second c a libr ation gas (i f a p plic able). Dip switch 6 is a llo ca t ed to the t hird calibration g a s (i f app lica bl e). To select th e gas, the dip s witch should b e turn ...

  • Omega 3200 - page 19

    M-4271/07 07, pg. 19 o f 26 E. Specific ations Series FMA 3200 FMA 3400 FMA 3200ST FMA 3400ST Ac cur a cy (including linearity) ±1.5% of Full Scal e* ±1. 5% o f Full Sc ale* Second and third gases ±3. 0% F .S. * ±1.5 % o f Full Sc ale* ±1.5 % of Full Sc ale* Second and thi rd ga ses ±3.0 % F. S .* Repeatability ±0.25% Full Scale* Pressure Ra ...

  • Omega 3200 - page 20

    M-4271/07 07, pg. 20 o f 26 F. Dimensions ALL DIMEN SIONS IN INCHE S (MIL LIMETERS IN BRAC KETS) FMA 3200/3200ST Series - 1/4 ” Stainl ess Fittings Shown ...

  • Omega 3200 - page 21

    M-4271/07 07, pg. 21 o f 26 FMA 3400/3400ST Series - 1/4 ” Stainl ess Fittings Shown ...

  • Omega 3200 - page 22

    M-4271/07 07, pg. 22 o f 26 G. Gas K Facto rs Gas Chemical Symbo l K Fa ct or Ace tylene C 2 H 2 0.58 9 Air - 1.00 0 Argon Ar 1.438 Butane C 4 H 10 0.2 60 Ca rbon D io xide CO 2 0.73 9 Deu teriu m D 2 1.00 0 Ethyl ene C 2 H 4 0.59 8 Freon 11 CCL 3 F 0.3 30 Freon 12 CCL 2 F 2 0.3 54 Freon 13 CCLF 3 0.38 5 Freon 14 CF 4 0.42 0 Freon 22 CHCLF 2 0.46 0 ...

  • Omega 3200 - page 23

    M-4271/07 07, pg. 23 o f 26 H. Troubleshooting Guide Symptom Poss ible Cau s e Method of Correction Clicking no ise from controlle r Unit i n error mode C heck there is suff icien t pres s ure and that th e f low path i s not restric ted or blocke d Unit wired incorrectly Check wiring is accordin g to Section B5 Loo se co nnectio n Check all c onne ...

  • Omega 3200 - page 24

    M-4271/07 07, pg. 24 o f 26 Symptom Poss ible Cau s e Method of Correction Insuf ficient or vary ing power Check the power supply ou tp ut a nd inc reas e i f necessary Insuf ficient pr essure En sur e the pres sure (an diffe r en tial pressu re) is high enou gh o op erat e the uni t. Varyin g pr essure Check the s tabi lity of the pressure regulat ...

  • Omega 3200 - page 25

    M-4271/07 07, pg. 25 o f 26 . ...

  • Omega 3200 - page 26

    M-4271/07 07, pg. 26 o f 26 ...

メーカー Omega カテゴリー Binding Machine

Omega 3200のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 3200の取扱説明書
- Omegaの製品カード
- パンフレット
- またはOmega 3200の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega 3200の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega 3200の取り付け説明書、サービスマニュアル、簡易説明書、またはOmega 3200のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega 3200の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega 3200デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega 3200を使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega 3200ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omegaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega 3200の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega 3200の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega 3200に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega 3200デバイスの基本機能を使うにあたってのヒント。 Omega 3200のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega 3200に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega 3200のメーカー/サービスへの連絡先に関する情報。

Omega 3200についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega 3200の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega 3200で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)