Manuel d’utilisation Harman Stove Company R6

13 pages 0.44 mb
Télécharger

Aller à la page of 13

Summary
  • Harman Stove Company R6 - page 1

    1 R6 INVINCIBLE "RS" OWNERS MANUAL ...

  • Harman Stove Company R6 - page 2

    2 Contents Manufactur ed by Harman Stove Company 352 Mountain House Road Halifax Pa. 17032 (717) 362-9080 Packing List 3 Installation & Assembly 3 V enting 5 Operation 9 ESP Control 1 2 Maintenance 1 3 W iring Diagram 1 6 Feeder Parts 1 7 T r ouble Shooting 18 Specifications 1 9 W arnings 2 0 ...

  • Harman Stove Company R6 - page 3

    3 Packing List Assembly and Installation Final Assembly Remove parts from ash pan. Install W ooden Door Handle with 1/4 x 20 x 2 1/2 bolt. Install Brass Hopper Knob with 10-32 x 1/2 bolt. Install the two Firebricks on the angle iron behind the burn pot as shown in fig. 1. Remove tape from Flame Guide and make sure it is resting on the burn pot as s ...

  • Harman Stove Company R6 - page 4

    4 Installing Place the stove on a noncombustible floor pro- tector and away from combustible walls at least as far as shown in figure 2 and 3. Note that the clear- ances shown are minimum for safety but do not leave much room for access when cleaning or servicing. Please take this into account when placing the stove. Place the Room Sensing Probe in ...

  • Harman Stove Company R6 - page 5

    5 V enting A combustion blower is used to extract the com- bustion gases from the firebox. This causes a nega- tive pressure in the firebox and a positive pressure in the venting system as shown in fig. 4. The longer the vent pipe and more elbows used in the system, the greater the flow resistance. Because of these facts we recommend using as few e ...

  • Harman Stove Company R6 - page 6

    6 #2 Preferr ed method This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall. The vertical portion of the vent should be three to five feet high and at least three inches from a combustible wall. This vertical section will provide natural draft in the event of a power fail- ure ...

  • Harman Stove Company R6 - page 7

    7 #4 Installing into an existing chimney ( US only ) This method provides excellent venting for nor- mal operation. This method also provides natural draft in the event of a power failure. If the chimney condition is questionable you may want to install a liner as in method #7. #5 Installing into an existing fireplace chimney ( US only ) This metho ...

  • Harman Stove Company R6 - page 8

    8 #6 Installing into an existing fireplace chimney ( US and Canada ) This method provides excellent venting for nor- mal operation. This method also provides natural draft in the event of a power failure. In Canada and some places in the US it is re- quired that the vent pipe extend all the way to the top of the chimney . In this method a cap shoul ...

  • Harman Stove Company R6 - page 9

    9 DO NOT INST ALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT . DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SER VING ANOTHER APPLIANCE. INST ALL VENT A T CLEARANCES SPECIFIED BY THE MANUF ACTURER Mobile home installation should be done in accordance with the Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24. DO NOT INST ALL ...

  • Harman Stove Company R6 - page 10

    10 Operation Starting First Fir e Be sure the power cord is plugged into a 120 volt receptacle. This can be verified by the red power light on the control panel. Fill the hopper with pellets, fig. 12. Fill the burn pot with pellets to a level just short of overflowing, fig. 8. Adjust feed rate . If this is your first fire or you are trying differen ...

  • Harman Stove Company R6 - page 11

    11 Starting a fir e after pr oper Feed Rate is known. Clean burn pot with scraper (supplied). Fill the hopper with pellets. Fill the burn pot with pellets to a level just short of overflowing. Adjust feed rate to proper setting. After you know what feed rate works well, then use that setting. (For example a setting of "5" produces 1" ...

  • Harman Stove Company R6 - page 12

    12 When to use "Stove T emp Mode" In "Stove T emp Mode" the Stove T emp Dial determines the temperature of the stove. Heat output and fuel consumption will remain con- stant. This makes it possible to tell how long a hopper full of pellets will last. The distribution blower speed will vary according to the position of the mode s ...

  • Harman Stove Company R6 - page 13

    13 ESP CONTROL Feed adjuster Sets the maximum feed rate T est Runs all motors at full speed for two minutes to check operation. After two minutes the stove will go to minimum burn and the blowers will alternate fr om high to low every two minutes to remind you that you are still in "T est Mode". Distribution Blower speed adjustment range. ...

Fabricant Harman Stove Company Catégorie Cooktop

Les documents que nous recevons du fabricant de l'appareilHarman Stove Company R6 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Harman Stove Company
- manuels d’utilisations R6
- fiches produit Harman Stove Company
- dépliants
- ou étiquettes-énergie Harman Stove Company R6
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Harman Stove Company R6.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Harman Stove Company R6, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Harman Stove Company R6. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Harman Stove Company R6.

Manuel d’utilisation complet de l’appareil Harman Stove Company R6, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Harman Stove Company R6 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Harman Stove Company R6.

Le manuel d’utilisation complet Harman Stove Company, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Harman Stove Company R6 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Harman Stove Company R6, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lHarman Stove Company R6 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Harman Stove Company R6 - qui devraient nous aider dans les premières étapes lors de l'utilisation Harman Stove Company R6
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Harman Stove Company R6
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Harman Stove Company R6 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Harman Stove Company R6?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Harman Stove Company R6, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Harman Stove Company R6 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)