Manuel d’utilisation Vulcan-Hart EF5 ML-114944

12 pages 0.24 mb
Télécharger

Aller à la page of 12

Summary
  • Vulcan-Hart EF5 ML-114944 - page 1

    INST ALLA TION & OPERA TION MANU AL VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791 FORM 31052 (1-98) MODELS EF3, EF4, & EF5 ECONOFR Y GAS FR YERS MODELS EF3 ML-52099 EF4 ML-114943 EF5 ML-114944 Model EF3 ...

  • Vulcan-Hart EF5 ML-114944 - page 2

    — 2 — IMPOR T ANT FOR Y OUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE ...

  • Vulcan-Hart EF5 ML-114944 - page 3

    — 3 — Installation, Operation and Care of MODELS EF3, EF4 & EF5 ECONOFR Y GAS FR YERS KEEP THESE INSTR UCTIONS FOR FUTURE USE GENERAL Your Vulcan-Hart Gas Fryer is produced with quality workmanship and material. Proper installation, usage and maintenance will result in many years of satisfactory performance. It is suggested that you thoroug ...

  • Vulcan-Hart EF5 ML-114944 - page 4

    — 4 — LOCATION The equipment area must be kept free and clear of combustible substances. Minimum clearance from combustible construction is 6" (152.4mm) from the sides and 6" (152.4mm) from the back of the fryer; minimum clearance from non-combustible construction is 0" from the sides and back of the fryer. There must be at least ...

  • Vulcan-Hart EF5 ML-114944 - page 5

    — 5 — Fig. 1 GAS CONNECTIONS All gas supply connections and any pipe joint compound must be resistant to the action of liquefied petroleum gases. The gas inlet is located at the lower left rear. Codes require that a gas shutoff valve be installed in the gas line ahead of the fryer. The gas supply line must be at least the equivalent of 1 / 2 &q ...

  • Vulcan-Hart EF5 ML-114944 - page 6

    — 6 — LEVELING THE FRYER Once gas connections have been made, place a spirit level on top of the fryer. Adjust the legs to ensure that the fryer is level front-to-back and side-to-side in the final installed position. FLUE CONNECTIONS Adequate ventilation must be provided and must comply with NFPA Standard #96 (latest edition), and with local c ...

  • Vulcan-Hart EF5 ML-114944 - page 7

    — 7 — OPERA TION WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT OIL CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER WITHOUT DRAINING ALL OIL FROM THE TANK. Tank warranty may be voided by improper operation. Turn gas valve off when draining or filling. FILL FRY TANK WITH LIQ ...

  • Vulcan-Hart EF5 ML-114944 - page 8

    — 8 — PL-40677-1 Drain V alve Gas Control V alve Knob Thermostat Knob LIGHTING THE PILOT 1. Turn thermostat OFF. Thermostat is located behind the door (Fig. 3). MODEL EF3 Fig. 3 2. Push gas control valve knob and turn to OFF (Fig. 4). Wait 5 minutes for unburned gas to vent. 3. Push and turn gas control valve to the "I" in PILOT (Fig. ...

  • Vulcan-Hart EF5 ML-114944 - page 9

    — 9 — TURNING THE FRYER OFF 1. Turn the thermostat OFF. 2. Turn the gas control valve knob so the "I" in PILOT is opposite the INDEX. In this position, the pilot remains lit. 3. To shut off all gas to the system, including the pilot, turn the gas control valve knob to OFF. EXTENDED SHUTDOWN 1. Turn the manual gas shutoff valve OFF. 2. ...

  • Vulcan-Hart EF5 ML-114944 - page 10

    — 10 — SHORTENING LIFE Shortening life may be extended by following these guidelines: • Do not salt foods over the fryer. • Use good quality shortening. • Filter shortening at least daily. • Replace shortening if it becomes poorly flavored. • Keep equipment and surroundings clean. • Set thermostats correctly. • Remove excess moist ...

  • Vulcan-Hart EF5 ML-114944 - page 11

    — 11 — 7. With a small amount of warm shortening, flush out scraps and sediment in the fry tank. Drain the tank thoroughly and wipe clean. 8. If it is necessary to clean the tank more thoroughly follow the procedure shown in CLEANING — WEEKLY OR AS REQUIRED. 9. Close the drain valve. 10. Pour the strained shortening back into the vat. 11. Add ...

  • Vulcan-Hart EF5 ML-114944 - page 12

    — 12 — MAINTENANCE WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT OIL CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER WITHOUT DRAINING ALL OIL FROM THE TANK. VENT Annually, when fryer is cool, check the flue and clear any obstructions. SERVICE AND PARTS INFORMATION To obtai ...

Fabricant Vulcan-Hart Catégorie Fryer

Les documents que nous recevons du fabricant de l'appareilVulcan-Hart EF5 ML-114944 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Vulcan-Hart
- manuels d’utilisations EF5 ML-114944
- fiches produit Vulcan-Hart
- dépliants
- ou étiquettes-énergie Vulcan-Hart EF5 ML-114944
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Vulcan-Hart EF5 ML-114944.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Vulcan-Hart EF5 ML-114944, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Vulcan-Hart EF5 ML-114944. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Vulcan-Hart EF5 ML-114944.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Vulcan-Hart EF5 ML-114944, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Vulcan-Hart EF5 ML-114944 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Vulcan-Hart EF5 ML-114944.

Le manuel d’utilisation complet Vulcan-Hart, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Vulcan-Hart EF5 ML-114944 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Vulcan-Hart EF5 ML-114944, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lVulcan-Hart EF5 ML-114944 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Vulcan-Hart EF5 ML-114944 - qui devraient nous aider dans les premières étapes lors de l'utilisation Vulcan-Hart EF5 ML-114944
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Vulcan-Hart EF5 ML-114944
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Vulcan-Hart EF5 ML-114944 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Vulcan-Hart EF5 ML-114944?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Vulcan-Hart EF5 ML-114944, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Vulcan-Hart EF5 ML-114944 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)