Manuel d’utilisation Connect Tech CTIM-00043

25 pages 0.88 mb
Télécharger

Aller à la page of 25

Summary
  • Connect Tech CTIM-00043 - page 1

    USER MANUAL CANpr o/104 CTIM-00043 (0.02) - January 15, 2010 ...

  • Connect Tech CTIM-00043 - page 2

    CANpro/104 User Manual CTIM-00043 (0.01) 1/15/2010 www.connecttech.com 2 800 -426-8979 | 519 -836-1291 Table of Conten ts Copyright Notice ................................................................................................................................................ 4 Trademark Ackno wledgement ..................................... ...

  • Connect Tech CTIM-00043 - page 3

    CANpro/104 User Manual 3 www.connecttech.com CTIM-00043 (0.01) 1/15/2010 800 -426-8979 | 519 -836-1291 J3A .......................................................................................................................................................... 16 J3B ................................................................................. ...

  • Connect Tech CTIM-00043 - page 4

    CANpro/104 User Manual CTIM-00043 (0.01) 1/15/2010 www.connecttech.com 4 800 -426-8979 | 519 -836-1291 Copyright Not ice The information contained in this document is subj ect to change without notice. Connect T ech Inc. shall not be liable for err ors contained herein or for incide ntal consequential da mages in connection with the furnishin g, pe ...

  • Connect Tech CTIM-00043 - page 5

    CANpro/104 User Manual CTIM-00043 (0.01) 1/15/2010 www.connecttech.com 5 800 -426-8979 | 519 -836-1291 Introduction CANpro/104 combines the power of two independent NXP SJA100 0 CAN controllers with the compact size and rugged stability of PC/10 4. CANpro/104 is ideal for industrial control ap plications exposed to harsh conditions or enviro nments ...

  • Connect Tech CTIM-00043 - page 6

    CANpro/104 User Manual CTIM-00043 (0.01) 1/15/2010 www.connecttech.com 6 800 -426-8979 | 519 -836-1291 Hardware Inst allation – Rev C & Later The Connect Tech CA Npro/10 4 board pr ovides two (2) industry standard SJA1000 C AN Bus controllers i n a PC/104 boar d format which supports bo th I/O and Memory mapping configurability. All the confi ...

  • Connect Tech CTIM-00043 - page 7

    CANpro/104 User Manual 7 www.connecttech.com CTIM-00043 (0.01) 1/15/2010 800 -426-8979 | 519 -836-1291 I/O Space This region is supported by all PC/104 CPU System board vendors, and co mmonly consists of I/O Addresses fro m 0x000 to 0x3FF, although so me Syste m boards support I /O addresses b eyond 0x3FF. (Note: So me I/O mappe d P C/104 expansion ...

  • Connect Tech CTIM-00043 - page 8

    CANpro/104 User Manual CTIM-00043 (0.01) 1/15/2010 www.connecttech.com 8 800 -426-8979 | 519 -836-1291 Secondly, the Me mory Spac e ca n be enabled by Applicatio n o r Driver soft ware, after the Operating system has started. This ca n be acco mplished b y writing a data value to an I/O Space Address which is d ecoded by the follo wing J 3B Jumper ...

  • Connect Tech CTIM-00043 - page 9

    CANpro/104 User Manual 9 www.connecttech.com CTIM-00043 (0.01) 1/15/2010 800 -426-8979 | 519 -836-1291 1. X = Address bit is ignored (and the correspo nding Jumper is Not Used ). 2. When Memory Space is selec ted, P C/104 Address bits 20 and 2 1 are alway s decoded as logical “0” . To determine which Ju mpers to install and which to remove, the ...

  • Connect Tech CTIM-00043 - page 10

    CANpro/104 User Manual CTIM-00043 (0.01) 1/15/2010 www.connecttech.com 10 800 -426-8979 | 519 -836-1291 PeliCAN vs BasicCAN Addressing Modes The SJA1000 can operate in 2 different modes, t he PeliCAN mode which has extended features and additional registers and which consume 128 bytes of address spac e per device (there are 2 devices on this board) ...

  • Connect Tech CTIM-00043 - page 11

    CANpro/104 User Manual 11 www .co nnecttech.com CTIM-00043 (0.01) 1/15/2010 800 -426-8979 | 519 -836-1291 Example #2: Memory Address 0x0C800 0 (this address is belo w the 1-Me g boundary) 0x0C8000 = 0000.1 100.100 X.XXXX.CJJJ .JJJJ (binary) Address Bit Bit Value J3A or J3B Position Installed or Removed 23 0 J3A-2 Removed 22 0 J3A-3 Removed 21 0 Add ...

  • Connect Tech CTIM-00043 - page 12

    CANpro/104 User Manual CTIM-00043 (0.01) 1/15/2010 www.connecttech.com 12 800 -426-8979 | 519 -836-1291 CAN Controller Addressing Table Once the Base Memor y or I/O Address is setup, t he 2 SJA1000 CAN controllers are accessed at the following address offsets. Accessed Resource Offset from Base Address Memory Space I/O Space BasicCAN m o de PeliCAN ...

  • Connect Tech CTIM-00043 - page 13

    CANpro/104 User Manual 13 www .co nnecttech.com CTIM-00043 (0.01) 1/15/2010 800 -426-8979 | 519 -836-1291 Common Memory Space Address Selections Most System boards allo w the PC/104 Bus stack to be allocated a po rtion of the memory addr ess located in the 256K r egion of memory just belo w the 1 -Meg ad dress boundary (Addresses 0x0C0000 to 0x0FFF ...

  • Connect Tech CTIM-00043 - page 14

    CANpro/104 User Manual CTIM-00043 (0.01) 1/15/2010 www.connecttech.com 14 800 -426-8979 | 519 -836-1291 Performance E nhancement PC/104 Memory and I/O Bus cycles are typicall y about 700 nS long in total, but the access spee d of the SJA1000 is considerab ly faster. The P C/104 Bus allows Memory and I/O Bus cycles to b e shortened b y the assertion ...

  • Connect Tech CTIM-00043 - page 15

    CANpro/104 User Manual 15 www .co nnecttech.com CTIM-00043 (0.01) 1/15/2010 800 -426-8979 | 519 -836-1291 Single Interrupt Mode This mode routes the interrupt signal from both SJ A1000 CAN co ntrollers to one PC/10 4 Bus Interrupt signal. This mod e is set up by installing Ju mper J1/J2 Position “S” (either the CAN-0 or the CAN- 1 “S” posit ...

  • Connect Tech CTIM-00043 - page 16

    CANpro/104 User Manual CTIM-00043 (0.01) 1/15/2010 www.connecttech.com 16 800 -426-8979 | 519 -836-1291 Security ID Feature Some users may wis h to assoc iate the operation of their software with a particular hard ware installation. To supp ort this ability, an ID mechani sm is availab le which uses a si mple, somewhat unusual (but predictable) Wri ...

  • Connect Tech CTIM-00043 - page 17

    CANpro/104 User Manual 17 www .co nnecttech.com CTIM-00043 (0.01) 1/15/2010 800 -426-8979 | 519 -836-1291 J3B Position Function Jumper Installed Jumper Removed 1 Mem Addr[16] or I/O Addr[9] = 1 Mem Addr[16] or I/O Addr[9] = 0 2 Mem Addr[15] or I/O Addr[8] = 1 Mem Addr[15] or I/O Addr[8] = 0 3 Mem Addr[14 ] = 1 or I/O Addr[7] = 1 (BasicCAN mode only ...

  • Connect Tech CTIM-00043 - page 18

    CANpro/104 User Manual CTIM-00043 (0.01) 1/15/2010 www.connecttech.com 18 800 -426-8979 | 519 -836-1291 Hardware Insta llation – Rev A & B Before you begin, take a minute to ensure that your package includes the req uired components that s hould have shipped with your CANpro/104. ● One CANpro/104 CAN controller bo ard ● One CD containing ...

  • Connect Tech CTIM-00043 - page 19

    CANpro/104 User Manual 19 www .co nnecttech.com CTIM-00043 (0.01) 1/15/2010 800 -426-8979 | 519 -836-1291 Interrupts and Memory I/O R ange Selecti on CANpro/104’s interrupt lines and I/O ranges are jumper assignable. Interrupt Selection J1 and J2 ar e used for interrupt selection. Interrupt selection for the first CAN co ntroller is achieved via ...

  • Connect Tech CTIM-00043 - page 20

    CANpro/104 User Manual CTIM-00043 (0.01) 1/15/2010 www.connecttech.com 20 800 -426-8979 | 519 -836-1291 Address Mode and Range Selection The first five jumper locatio ns of ju mper block J3 are used for b oard address selection. T he first jumper location (Addr Mo de) selects the number of addr ess bits to use for the d ecoding of the board address ...

  • Connect Tech CTIM-00043 - page 21

    CANpro/104 User Manual 21 www .co nnecttech.com CTIM-00043 (0.01) 1/15/2010 800 -426-8979 | 519 -836-1291 Interrupt Sharing Jumper block J3 also plays a part in the interrupt shari ng. PC/104 suppor ts the sharing of an interrupt between multiple car ds. For example, two separate C ANpro/104 cards are able to share the same interrupt across all fou ...

  • Connect Tech CTIM-00043 - page 22

    CANpro/104 User Manual CTIM-00043 (0.01) 1/15/2010 www.connecttech.com 22 800 -426-8979 | 519 -836-1291 Other On-b oard Jumper Selec tion Near each I/O connector a 2 x2 jumper block (either J4 or J5) will allow the config uration of both bus termination and slew r ate limiting for the tra nsceiver. J4 configures options for CAN controller 0, while ...

  • Connect Tech CTIM-00043 - page 23

    CANpro/104 User Manual CTIM-00043 (0.01) 1/15/2010 www.connecttech.com 23 800 -426-8979 | 519 -836-1291 Connector Pin outs Table 25 : DB-9 Cable Connector Pinouts Pin No. Signal 1 +5V 2 CAN-L 3 CAN GND (isolated or non) 4 N/C 5 N/C 6 CAN GND (isolated or non) 7 CAN-H 8 N/C 9 +5V Male D B-9 Co nnector 1 5 6 9 For boards po pulated with right a ngled ...

  • Connect Tech CTIM-00043 - page 24

    CANpro/104 User Manual CTIM-00043 (0.01) 1/15/2010 www.connecttech.com 24 800 -426-8979 | 519 -836-1291 Specification s Operating Environment Storage temperature: - 40 C to 125 C Operating temperature: - 40 C to 85 C Humidity: 95%, non-condensi ng Power Requirements +5 VDC @ 500 mA (maximum) 380 mA (minimu m) NOTE: Power output on CAN co nnectors m ...

  • Connect Tech CTIM-00043 - page 25

    CANpro/104 User Manual 25 www .co nnecttech.com CTIM-00043 (0.01) 1/15/2010 800 -426-8979 | 519 -836-1291 Limited Lifetim e Warranty Connect Tech Inc. p rovides a Lifetime Warrant y for all Connect Tech Inc. pr oducts. Should this prod uct, in Connect Tech Inc.'s op inion, fail to b e in good working order during the warranty period, Connect T ...

Fabricant Connect Tech Catégorie Computer Accessories

Les documents que nous recevons du fabricant de l'appareilConnect Tech CTIM-00043 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Connect Tech
- manuels d’utilisations CTIM-00043
- fiches produit Connect Tech
- dépliants
- ou étiquettes-énergie Connect Tech CTIM-00043
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Connect Tech CTIM-00043.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Connect Tech CTIM-00043, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Connect Tech CTIM-00043. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Connect Tech CTIM-00043.

Manuel d’utilisation complet de l’appareil Connect Tech CTIM-00043, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Connect Tech CTIM-00043 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Connect Tech CTIM-00043.

Le manuel d’utilisation complet Connect Tech, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Connect Tech CTIM-00043 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Connect Tech CTIM-00043, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lConnect Tech CTIM-00043 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Connect Tech CTIM-00043 - qui devraient nous aider dans les premières étapes lors de l'utilisation Connect Tech CTIM-00043
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Connect Tech CTIM-00043
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Connect Tech CTIM-00043 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Connect Tech CTIM-00043?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Connect Tech CTIM-00043, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Connect Tech CTIM-00043 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)