Manuel d’utilisation Verona VEFSGE 304 SC..

24 pages 5.44 mb
Télécharger

Aller à la page of 24

Summary
  • Verona VEFSGE 304 SC.. - page 1

    GAS/ELECTRIC RANGE for residential use only THIS RANGE IS FOR RESIDENTIAL USE ONL Y FOR INST ALLER ONL Y Some models are supplied with a protective lm on steel and aluminium parts. This lm must be removed before installing/using the appliance. Models: VEFSGE 304 SC.. INST ALLA TION INSTRUCTIONS IMPORT ANT - PLEASE READ AND FOLLOW • Befor ...

  • Verona VEFSGE 304 SC.. - page 2

    2 WARNING ! T o reduce the risk of tipping the appliance, the appliance must be secured by properly installed anti-tip device packed with the appliance. • ALL RANGES CAN TIP • INJUR Y T O PERSONS COULD RESUL T • INST ALL ANTI-TIP DEVICE P ACKED WITH RANGE • SEE INST ALLA TION INSTRUCTIONS  – Do not store or use gasoline or other amm ...

  • Verona VEFSGE 304 SC.. - page 3

    3 This appliance isdesigned and manufactured solely forthe cooking of domestic (household) food and in not suitable for any none domestic application and therefore should not be used in a com- mercialenvironmement. Theappliance warrantywill b ...

  • Verona VEFSGE 304 SC.. - page 4

    4 INST ALLA TION INSTRUCTIONS W ARNING! THIS APPLIANCE MUST BE INST ALLED BY A QUALIFIED INST ALLER. Improper installation, adjustment, alteration, services, or maintenance can cause injury or property damage. Consult a quali - ed installer , service agent, or the gas supplier . Screwdriver 2 - Wrench T-handle wrench Tape measure Pencil Adjustab ...

  • Verona VEFSGE 304 SC.. - page 5

    5 GENERAL INFORMA TION 1. Installation must conform with local codes or , in the absen- ce of local codes, with the National Fuel Gas Code , ANSI Z223.1/NFP A 54  - Latest Edition, CAN/CGA-B149.1 or CAN/ CGA-B149.2. 2. Installation in manufactured (mobile) hom ...

  • Verona VEFSGE 304 SC.. - page 6

    6 PROXIMITY T O SIDE CABINETS 1. This range may be installed directly adjacent to existing 36” (914 mm) highbasecabinets.   Rangedimensions: • width:29”7/8(759mm) • depth:24”13/64(614.9mm) • height (without backguard): MIN 35” 21/32? ...

  • Verona VEFSGE 304 SC.. - page 7

    7 A A B ASSEMBLING THE BACKGUARD It is mandatory to install the backguard. Assemblethebackguardasshowningure1.3: • Screwthe2screws“ A ”interposingthespacers. • Screwthecentralscrew“ B ”. 1 Fig. 1.3 GAS AND ELECTRIC CONNECTION Fig. 1.2 Dottedlineshowingtheposition ...

  • Verona VEFSGE 304 SC.. - page 8

    8 B G E D C F A A B C E D F G A A PROXIMITY T O SIDE CABINETS ST ANDARD INST ALLA TION Fig. 1.4b Fig. 1.4a OVEN VENT Ref. inch mm A 0” 0 B 36” 914 C 1 1”13/16 300 D 30”minimum 762minimum E 18”minimum 457minimum F 13”maximum 330maximum G 20”minimum 500minimum OVEN VENT 1 ...

  • Verona VEFSGE 304 SC.. - page 9

    9 PROXIMITY T O SIDE CABINETS ISLAND INST ALLA TION A A B G E D F C H A A B G E D F C H Fig. 1.5b Fig. 1.5a OVEN VENT Ref. inch mm A 0” 0 B 36” 914 C 1 1”13/16 300 D 30”minimum 762minimum E 18”minimum 457minimum F 13”maximum 330maximum G 20”minimum 500minimum H 12”minimum 305minimum OVEN VENT 1 ...

  • Verona VEFSGE 304 SC.. - page 10

    10 1 LEVELLING THE RANGE Therange isequipped with4 LEVELLINGFEETand maybe levelledby screwingor unscrewingthefeet(gs.1.6-1.7). Itisimportanttoobservethedirectionsofgures1.6,1.8a,1.8b. Fig. 1.8b Fig. 1.8a Fig. 1.7 Fig. 1.6 Suppliedwiththera ...

  • Verona VEFSGE 304 SC.. - page 11

    11 1 INST ALLING THE COOKTOP FRONT GUARD T o increasethe clearance between the front edgeof the cooktop and the burnersit is possible to install thecooktop front guard supplied withtheappliance. IMPORT ANT : T o install/remove the guard it is necessary to remove the cookt ...

  • Verona VEFSGE 304 SC.. - page 12

    12 gas connection 2 2. Pressure Regulator: a. Allheavyduty ,commercialtypecookingequipmentmusthaveapressureregulator onthe incomingservice linefor safeand efcientoperation, sinceservice pressure mayuctuatewithlocaldemand.   Before installing ...

  • Verona VEFSGE 304 SC.. - page 13

    13 2 LOCK Arrow PRESSURE REGULA TOR INST ALLA TION STEP 1 Mountthe1/2”NPT (conical)maleconnectortothepressureregulatorand tightenbyusingawrench. Donotovertightentheconnector . Overtighteningmaycrackregulator . STEP 2 Assemblethe1/2”NPTconnector+pressure ...

  • Verona VEFSGE 304 SC.. - page 14

    14 2 Fig. 2.4 GAS CONNECTION SPEFICICA TION Range manifold Manifold male pipe tting 1/2”Gcylindrical (ISO228-1)male 1/2”Gcylindrical (ISO228-1)female Gasket Extension pipe female pipe tting T orange 1/2”Gcylindrical (ISO228-1)female Extension pipe 1/2”Gcylindrical (ISO228-1)male Exten ...

  • Verona VEFSGE 304 SC.. - page 15

    15 2 b. Any conversion required must beperformed by yourdealer or aqualied licen- sed technician or gas service company . Please providethe service person with this manual before work is started on the range. (Gas conversions are the ...

  • Verona VEFSGE 304 SC.. - page 16

    16 2 Pressur e regulator 1 2 NATURAL GAS REGULATION LP/PROPANE REGULATION A REGULA TOR COVER CONVERSION TO LP/PROP ANE GAS (OR CONVERSION BACK TO THE ORIGINAL GAS - NA TURAL GAS) Everyrangeisprovidedwithasetofinjectorsforthevarioustypesofgas. Selecttheinjectorstobereplacedaccordingto ...

  • Verona VEFSGE 304 SC.. - page 17

    17 2 OPERA TIONS TO BE PERFORMED WHEN SUBSTITUTING THE INJECTORS • Removethepansupports,theburnercapsandtheamespreaders. • Dualburner only(g. 2.9):Unscrew theno.3 xingscrews “ A ”and removethe inner crown ame spreader “ B ”; then ...

  • Verona VEFSGE 304 SC.. - page 18

    18 Fig. 2.10 R 1  Regulationscrew(Semirapidburner) R 2  Regulationscrew(Innercrownofdualburner) R 3  Regulationscrew(Outercrownofdualburner) R 1 R 3 R 2 SETTING THE BURNER MINIMUM Whenswitchingfrom onetypeof gastoanother ,theminimumow ratemustalso ...

  • Verona VEFSGE 304 SC.. - page 19

    19 electrical connection 3 W ARNING TO A VOID ELECTRICAL SHOCK HA- ZARD, BEFORE INST ALLING THE APPLIANCE, SWITCH POWER OFF A T THE SERVICE P ANEL AND LOCK THE P ANEL TO PREVENT THE PO- WER FROM BEING SWITCHED ON ACCIDENT ALL Y . ELECTRICAL REQUIREMENTS • Thisappliance must beproperly installed and groundedby a qu ...

  • Verona VEFSGE 304 SC.. - page 20

    20 3 3-Wire Power Cord Installation (SeeFigure3.2) 1. Remove the T erminal Block Access Plate on the back of the rangebyunscrewingthe4xing Screws (Figure3.1). 2. Check the correct positioning of the Power Cord Bracket  as pergure3.2. 3. Assemble ...

  • Verona VEFSGE 304 SC.. - page 21

    21 3 3-Wire Conduit Installation (SeeFigure3.5) 1. Remove the T erminal Block Access Plate on the back of the rangebyunscrewingthe4xing Screws (Figure3.4). 2. Check the correct positioning of the Conduit Bracket  as per gure3.5. 3. Feed 1/2” ( ...

  • Verona VEFSGE 304 SC.. - page 22

    22 3 WIRING DIAGRAM ELECTRIC DIAGRAM KEY IC  IGNITIONCOIL ISG  IGNITIONSWITCHESGROUP OL  OVENLAMP E61  RELA Y CE  CIRCULARELEMENT GE  BROIL ELEMENT TE  TOP ELEMENT BE-INT  BOTTOMELEMENT INT . BE-EXT  BOTTOMELEMENT EXT . TPL  THERMOST A TPILOT LAMP DSPL  DOORSAFETYPILOT ? ...

  • Verona VEFSGE 304 SC.. - page 23

    23 ...

  • Verona VEFSGE 304 SC.. - page 24

    Themanufacturer cannot beheld responsiblefor possibleinaccuracies due toprin- tingortranscriptionerrorsinthepresentbooklet. The manufacturer reservesthe right to make all modications to its products dee- med necessaryfor manufacture orcommerc ...

Fabricant Verona Catégorie Range

Les documents que nous recevons du fabricant de l'appareilVerona VEFSGE 304 SC.. peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Verona
- manuels d’utilisations VEFSGE 304 SC..
- fiches produit Verona
- dépliants
- ou étiquettes-énergie Verona VEFSGE 304 SC..
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Verona VEFSGE 304 SC...

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Verona VEFSGE 304 SC.., manuels d’entretien, brefs manuels ou manuels de l’utilisateur Verona VEFSGE 304 SC... Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Verona VEFSGE 304 SC...

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Verona VEFSGE 304 SC.., quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Verona VEFSGE 304 SC.. par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Verona VEFSGE 304 SC...

Le manuel d’utilisation complet Verona, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Verona VEFSGE 304 SC.. - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Verona VEFSGE 304 SC.., FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lVerona VEFSGE 304 SC.. qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Verona VEFSGE 304 SC.. - qui devraient nous aider dans les premières étapes lors de l'utilisation Verona VEFSGE 304 SC..
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Verona VEFSGE 304 SC..
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Verona VEFSGE 304 SC.. dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Verona VEFSGE 304 SC..?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Verona VEFSGE 304 SC.., avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Verona VEFSGE 304 SC.. il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)