    GAS/ELECTRIC RANGE for residential use only THIS RANGE IS FOR RESIDENTIAL USE ONL Y FOR INST ALLER ONL Y Some models are supplied with a protective lm on steel and aluminium parts. This lm must be removed before installing/using the appliance. Models: VEFSGE 304 SC.. INST ALLA TION INSTRUCTIONS IMPORT ANT - PLEASE READ AND FOLLOW • Befor ...

  • Verona VEFSGE 304 SC.. - page 2

    2 WARNING ! T o reduce the risk of tipping the appliance, the appliance must be secured by properly installed anti-tip device packed with the appliance. • ALL RANGES CAN TIP • INJUR Y T O PERSONS COULD RESUL T • INST ALL ANTI-TIP DEVICE P ACKED WITH RANGE • SEE INST ALLA TION INSTRUCTIONS  – Do not store or use gasoline or other amm ...

  • Verona VEFSGE 304 SC.. - page 3

    3 This appliance isdesigned and manufactured solely forthe cooking of domestic (household) food and in not suitable for any none domestic application and therefore should not be used in a com- mercialenvironmement. Theappliance warrantywill b ...

  • Verona VEFSGE 304 SC.. - page 4

    4 INST ALLA TION INSTRUCTIONS W ARNING! THIS APPLIANCE MUST BE INST ALLED BY A QUALIFIED INST ALLER. Improper installation, adjustment, alteration, services, or maintenance can cause injury or property damage. Consult a quali - ed installer , service agent, or the gas supplier . Screwdriver 2 - Wrench T-handle wrench Tape measure Pencil Adjustab ...

  • Verona VEFSGE 304 SC.. - page 5

    5 GENERAL INFORMA TION 1. Installation must conform with local codes or , in the absen- ce of local codes, with the National Fuel Gas Code , ANSI Z223.1/NFP A 54  - Latest Edition, CAN/CGA-B149.1 or CAN/ CGA-B149.2. 2. Installation in manufactured (mobile) hom ...

  • Verona VEFSGE 304 SC.. - page 6

    6 PROXIMITY T O SIDE CABINETS 1. This range may be installed directly adjacent to existing 36” (914 mm) highbasecabinets.   Rangedimensions: • width:29”7/8(759mm) • depth:24”13/64(614.9mm) • height (without backguard): MIN 35” 21/32? ...

  • Verona VEFSGE 304 SC.. - page 7

    7 A A B ASSEMBLING THE BACKGUARD It is mandatory to install the backguard. Assemblethebackguardasshowningure1.3: • Screwthe2screws“ A ”interposingthespacers. • Screwthecentralscrew“ B ”. 1 Fig. 1.3 GAS AND ELECTRIC CONNECTION Fig. 1.2 Dottedlineshowingtheposition ...

  • Verona VEFSGE 304 SC.. - page 8

    8 B G E D C F A A B C E D F G A A PROXIMITY T O SIDE CABINETS ST ANDARD INST ALLA TION Fig. 1.4b Fig. 1.4a OVEN VENT Ref. inch mm A 0” 0 B 36” 914 C 1 1”13/16 300 D 30”minimum 762minimum E 18”minimum 457minimum F 13”maximum 330maximum G 20”minimum 500minimum OVEN VENT 1 ...

  • Verona VEFSGE 304 SC.. - page 9

    9 PROXIMITY T O SIDE CABINETS ISLAND INST ALLA TION A A B G E D F C H A A B G E D F C H Fig. 1.5b Fig. 1.5a OVEN VENT Ref. inch mm A 0” 0 B 36” 914 C 1 1”13/16 300 D 30”minimum 762minimum E 18”minimum 457minimum F 13”maximum 330maximum G 20”minimum 500minimum H 12”minimum 305minimum OVEN VENT 1 ...

  • Verona VEFSGE 304 SC.. - page 10

    10 1 LEVELLING THE RANGE Therange isequipped with4 LEVELLINGFEETand maybe levelledby screwingor unscrewingthefeet(gs.1.6-1.7). Itisimportanttoobservethedirectionsofgures1.6,1.8a,1.8b. Fig. 1.8b Fig. 1.8a Fig. 1.7 Fig. 1.6 Suppliedwiththera ...

  • Verona VEFSGE 304 SC.. - page 11

    11 1 INST ALLING THE COOKTOP FRONT GUARD T o increasethe clearance between the front edgeof the cooktop and the burnersit is possible to install thecooktop front guard supplied withtheappliance. IMPORT ANT : T o install/remove the guard it is necessary to remove the cookt ...

  • Verona VEFSGE 304 SC.. - page 12

    12 gas connection 2 2. Pressure Regulator: a. Allheavyduty ,commercialtypecookingequipmentmusthaveapressureregulator onthe incomingservice linefor safeand efcientoperation, sinceservice pressure mayuctuatewithlocaldemand.   Before installing ...

  • Verona VEFSGE 304 SC.. - page 13

    13 2 LOCK Arrow PRESSURE REGULA TOR INST ALLA TION STEP 1 Mountthe1/2”NPT (conical)maleconnectortothepressureregulatorand tightenbyusingawrench. Donotovertightentheconnector . Overtighteningmaycrackregulator . STEP 2 Assemblethe1/2”NPTconnector+pressure ...

  • Verona VEFSGE 304 SC.. - page 14

    14 2 Fig. 2.4 GAS CONNECTION SPEFICICA TION Range manifold Manifold male pipe tting 1/2”Gcylindrical (ISO228-1)male 1/2”Gcylindrical (ISO228-1)female Gasket Extension pipe female pipe tting T orange 1/2”Gcylindrical (ISO228-1)female Extension pipe 1/2”Gcylindrical (ISO228-1)male Exten ...

  • Verona VEFSGE 304 SC.. - page 15

    15 2 b. Any conversion required must beperformed by yourdealer or aqualied licen- sed technician or gas service company . Please providethe service person with this manual before work is started on the range. (Gas conversions are the ...

  • Verona VEFSGE 304 SC.. - page 16

    16 2 Pressur e regulator 1 2 NATURAL GAS REGULATION LP/PROPANE REGULATION A REGULA TOR COVER CONVERSION TO LP/PROP ANE GAS (OR CONVERSION BACK TO THE ORIGINAL GAS - NA TURAL GAS) Everyrangeisprovidedwithasetofinjectorsforthevarioustypesofgas. Selecttheinjectorstobereplacedaccordingto ...

  • Verona VEFSGE 304 SC.. - page 17

    17 2 OPERA TIONS TO BE PERFORMED WHEN SUBSTITUTING THE INJECTORS • Removethepansupports,theburnercapsandtheamespreaders. • Dualburner only(g. 2.9):Unscrew theno.3 xingscrews “ A ”and removethe inner crown ame spreader “ B ”; then ...

  • Verona VEFSGE 304 SC.. - page 18

    18 Fig. 2.10 R 1  Regulationscrew(Semirapidburner) R 2  Regulationscrew(Innercrownofdualburner) R 3  Regulationscrew(Outercrownofdualburner) R 1 R 3 R 2 SETTING THE BURNER MINIMUM Whenswitchingfrom onetypeof gastoanother ,theminimumow ratemustalso ...

  • Verona VEFSGE 304 SC.. - page 19

    19 electrical connection 3 W ARNING TO A VOID ELECTRICAL SHOCK HA- ZARD, BEFORE INST ALLING THE APPLIANCE, SWITCH POWER OFF A T THE SERVICE P ANEL AND LOCK THE P ANEL TO PREVENT THE PO- WER FROM BEING SWITCHED ON ACCIDENT ALL Y . ELECTRICAL REQUIREMENTS • Thisappliance must beproperly installed and groundedby a qu ...

  • Verona VEFSGE 304 SC.. - page 20

    20 3 3-Wire Power Cord Installation (SeeFigure3.2) 1. Remove the T erminal Block Access Plate on the back of the rangebyunscrewingthe4xing Screws (Figure3.1). 2. Check the correct positioning of the Power Cord Bracket  as pergure3.2. 3. Assemble ...

  • Verona VEFSGE 304 SC.. - page 21

    21 3 3-Wire Conduit Installation (SeeFigure3.5) 1. Remove the T erminal Block Access Plate on the back of the rangebyunscrewingthe4xing Screws (Figure3.4). 2. Check the correct positioning of the Conduit Bracket  as per gure3.5. 3. Feed 1/2” ( ...

  • Verona VEFSGE 304 SC.. - page 22

    22 3 WIRING DIAGRAM ELECTRIC DIAGRAM KEY IC  IGNITIONCOIL ISG  IGNITIONSWITCHESGROUP OL  OVENLAMP E61  RELA Y CE  CIRCULARELEMENT GE  BROIL ELEMENT TE  TOP ELEMENT BE-INT  BOTTOMELEMENT INT . BE-EXT  BOTTOMELEMENT EXT . TPL  THERMOST A TPILOT LAMP DSPL  DOORSAFETYPILOT ? ...

  • Verona VEFSGE 304 SC.. - page 23

    23 ...

  • Verona VEFSGE 304 SC.. - page 24

    Themanufacturer cannot beheld responsiblefor possibleinaccuracies due toprin- tingortranscriptionerrorsinthepresentbooklet. The manufacturer reservesthe right to make all modications to its products dee- med necessaryfor manufacture orcommerc ...

Fabbricante Verona Categoria Range

I documenti che otteniamo dal fabbricante del dispositivoVerona VEFSGE 304 SC.. possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Verona
- manuali per l’uso VEFSGE 304 SC..
- schede prodotto Verona
- opuscoli
- o etichette energetiche Verona VEFSGE 304 SC..
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Verona VEFSGE 304 SC...

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Verona VEFSGE 304 SC.., manuali di manutenzione, brevi manuali o manuali utente Verona VEFSGE 304 SC... A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Verona VEFSGE 304 SC...

Manuali per l’uso simili

Manuale completo del dispositivo Verona VEFSGE 304 SC.., come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Verona VEFSGE 304 SC.. dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Verona VEFSGE 304 SC...

Il manuale per l’uso completo Verona, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Verona VEFSGE 304 SC.. - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Verona VEFSGE 304 SC.., FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Verona VEFSGE 304 SC.. che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Verona VEFSGE 304 SC.. - che ci dovrebbe aiutare nei primi passi durante l'uso Verona VEFSGE 304 SC..
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Verona VEFSGE 304 SC..
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Verona VEFSGE 304 SC.. in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Verona VEFSGE 304 SC..?

Utilizza il modulo sottostante

Se non hai risolto il problema con Verona VEFSGE 304 SC.. con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Verona VEFSGE 304 SC.. è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)