Manuel d’utilisation Omega FTB600B

26 pages 0.41 mb
Télécharger

Aller à la page of 26

Summary
  • Omega FTB600B - page 1

    omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info FTB600B Series Ultra-Low Flow Sensors Shop online at U ser ’ s Guide ...

  • Omega FTB600B - page 2

    OMEGAnet ® On-Line Service Internet e-mail omega.com info@omega.com It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certi ...

  • Omega FTB600B - page 3

    TABLE OF CONTENTS FTB600B Series Ultra-Low Flow Sensors i Section Page Section 1 Introduction ...................................................................... 1 A. General Description .................................................... 1 B. Principle of Operation ................................................. 1 C. Material Characteristics ...

  • Omega FTB600B - page 4

    ii FTB600B Series Ultra-Low Flow Sensors NOTES: ...

  • Omega FTB600B - page 5

    1 1 FTB600B Series Installation IMPORTANT: READ INSTRUCTIONS THOROUGHLY BEFORE INSTALLING FLOW METER Section 1 - Introduction A. General Description The FTB600B Series is an axial paddle wheel turbine type flow meter based on the pelton wheel principle. This unique patented design makes the FTB600B Series a very accurate, repeatable, linear device. ...

  • Omega FTB600B - page 6

    2 FTB600B Series Installation 1 C. Material Characteristics of PVDF (Polyvinylidene Fluoride) 1. Material of construction Trade name - Kynar All wetted parts of the FTB600B Series are PVDF, excluding the O-ring. Wetted parts include any part of the meter that will or could come in contact with the fluid. List of wetted parts: 1. Barbed fittings 5. ...

  • Omega FTB600B - page 7

    3 2 FTB600B Series Operating Parameters Section 2. - Operating Parameters A. Temperature Since the FTB600B Series has printed circuit boards molded into the body of the meter it is strongly recommended that 180°F not be exceeded. Exceeding 180°F can cause irreparable damage to the circuit boards. B. Flow Ranges The FTB600B Series is available in ...

  • Omega FTB600B - page 8

    4 FTB600B Series Operation Parameters 2 ...

  • Omega FTB600B - page 9

    5 FTB600B Series Operating Parameters 2 C. Recommended Viscosity Range 1-5 cSt (w/o correction) The effects of changing viscosity on the FTB600B Series are the same as any other turbine flow meter. It is important to remember that a turbine meter is a viscosity dependent device, where as the viscosity increases the linearity of the flow meter will ...

  • Omega FTB600B - page 10

    6 3 FTB600B Series Silicone Treatment Section 3 - Silicone Treatment Silicone treatment is standard for all types of the FTB600B Series series electronics. ...

  • Omega FTB600B - page 11

    7 4 FTB600B Series Infrared Sensors Section 4 - Infrared Sensor A. Supply Voltage 24 Vdc. Do not exceed 24 Vdc. Doing so can cause overheating and eventual failure of all PC boards. Printed circuit boards are non- repairable. B. Frequency Output 1. Square wave pulse, unscaled (See Figure 4-1) 2. Output impedance 75 ohms 3. Directly proportional to ...

  • Omega FTB600B - page 12

    8 FTB600B Series Infrared Sensors 4 C. Frequency Ranges for (non-cartridge models) pulses/l Model Frequency (Hz) K-Factor FTB601B 60 to 1200 36,000 FTB602B 40 to 1200 8,000 FTB603B 27 to 800 3,200 FTB604B 20 to 600 1,200 FTB605B 18.75 to 562 450 FTB606B 15 to 450 225 D. Cable Requirements 1. 20 to 22 AWG (American Wire Gauge) 2. 4 conductor-shielde ...

  • Omega FTB600B - page 13

    9 FTB600B Series Infrared Sensors 4 Figure 4-1. Output Frequency Waveforms ...

  • Omega FTB600B - page 14

    10 5 FTB600B Series Installation Section 5 - Installing the FTB600B Series in the fluid line. A. Make sure the fluid is compatible with PVDF (polyvinylidene fluoride) and meets viscosity, pressure and temperature parameters of the FTB600B Series. The fluid must also meet filtration requirements as listed in 3D. B. Install the FTB600B series in the ...

  • Omega FTB600B - page 15

    11 FTB600B Series Installation 5 Figure 5-1. Supply Voltage and Signal Output Connections ...

  • Omega FTB600B - page 16

    12 FTB600B Series Installation 5 Table 5-1. Piping Table ...

  • Omega FTB600B - page 17

    13 FTB600B Series Installation 5 Table 5-1. Piping Table Con't. ...

  • Omega FTB600B - page 18

    14 6 FTB600B Series Specifications Section 6 - Specifications Accuracy: ±3% of reading Repeatability: ±0.1% of reading Linearity: ±1% of reading Viscosity Range: 1 to 15 centistokes Working Pressure: 150 PSIG at 175°F Wetted Materials: PVDF Power Supply: 5 to 18 Vdc, 6 to 33 mA Output Signal : Unscaled square wave Pressure Drop: See Section 7 ...

  • Omega FTB600B - page 19

    15 7 FTB600B Series Pressure Drop Curves Section 7 - Pressure Drop Curves Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB601 50 0.5 0 1.0 Liters/minute kP a 1.5 2.0 45 40 35 30 25 20 15 10 5 0 ...

  • Omega FTB600B - page 20

    16 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB602 250 2.0 0 4.0 Liters/minute kP a 8 .0 6.0 10.0 200 150 100 50 0 ...

  • Omega FTB600B - page 21

    17 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB603 200 51 0 1 5 0 Liters/minute kP a 160 1 8 0 140 100 8 0 60 40 20 120 0 ...

  • Omega FTB600B - page 22

    18 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB604 200 10 20 30 0 Liters/minute kP a 160 1 8 0 140 100 8 0 60 40 20 120 0 ...

  • Omega FTB600B - page 23

    19 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB605A 160 140 120 100 8 0 60 40 20 10 20 30 40 50 60 0 Liters/minute kP a 0 ...

  • Omega FTB600B - page 24

    20 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB606A 1 8 0 160 140 120 100 8 0 60 40 20 10 20 30 40 50 60 70 8 09 0 0 Liters/minute kP a 0 ...

  • Omega FTB600B - page 25

    FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repa ...

  • Omega FTB600B - page 26

    TEMPERATURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ Wire: Thermocouple, RTD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 ⻬ Recorders, Controllers & Process Monitors 䡺 ⻬ Infrared Pyrometers PRESSURE, STRAIN AND FORCE 䡺 ⻬ Transducers & Strain Gages 䡺 ⻬ ...

Fabricant Omega Catégorie Stud Sensor

Les documents que nous recevons du fabricant de l'appareilOmega FTB600B peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Omega
- manuels d’utilisations FTB600B
- fiches produit Omega
- dépliants
- ou étiquettes-énergie Omega FTB600B
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Omega FTB600B.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Omega FTB600B, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Omega FTB600B. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Omega FTB600B.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Omega FTB600B, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Omega FTB600B par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Omega FTB600B.

Le manuel d’utilisation complet Omega, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Omega FTB600B - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Omega FTB600B, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lOmega FTB600B qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Omega FTB600B - qui devraient nous aider dans les premières étapes lors de l'utilisation Omega FTB600B
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Omega FTB600B
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Omega FTB600B dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Omega FTB600B?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Omega FTB600B, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Omega FTB600B il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)