Manual Omega FTB600B

26 pages 0.41 mb
Download

Go to site of 26

Summary
  • Omega FTB600B - page 1

    omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info FTB600B Series Ultra-Low Flow Sensors Shop online at U ser ’ s Guide ...

  • Omega FTB600B - page 2

    OMEGAnet ® On-Line Service Internet e-mail omega.com info@omega.com It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certi ...

  • Omega FTB600B - page 3

    TABLE OF CONTENTS FTB600B Series Ultra-Low Flow Sensors i Section Page Section 1 Introduction ...................................................................... 1 A. General Description .................................................... 1 B. Principle of Operation ................................................. 1 C. Material Characteristics ...

  • Omega FTB600B - page 4

    ii FTB600B Series Ultra-Low Flow Sensors NOTES: ...

  • Omega FTB600B - page 5

    1 1 FTB600B Series Installation IMPORTANT: READ INSTRUCTIONS THOROUGHLY BEFORE INSTALLING FLOW METER Section 1 - Introduction A. General Description The FTB600B Series is an axial paddle wheel turbine type flow meter based on the pelton wheel principle. This unique patented design makes the FTB600B Series a very accurate, repeatable, linear device. ...

  • Omega FTB600B - page 6

    2 FTB600B Series Installation 1 C. Material Characteristics of PVDF (Polyvinylidene Fluoride) 1. Material of construction Trade name - Kynar All wetted parts of the FTB600B Series are PVDF, excluding the O-ring. Wetted parts include any part of the meter that will or could come in contact with the fluid. List of wetted parts: 1. Barbed fittings 5. ...

  • Omega FTB600B - page 7

    3 2 FTB600B Series Operating Parameters Section 2. - Operating Parameters A. Temperature Since the FTB600B Series has printed circuit boards molded into the body of the meter it is strongly recommended that 180°F not be exceeded. Exceeding 180°F can cause irreparable damage to the circuit boards. B. Flow Ranges The FTB600B Series is available in ...

  • Omega FTB600B - page 8

    4 FTB600B Series Operation Parameters 2 ...

  • Omega FTB600B - page 9

    5 FTB600B Series Operating Parameters 2 C. Recommended Viscosity Range 1-5 cSt (w/o correction) The effects of changing viscosity on the FTB600B Series are the same as any other turbine flow meter. It is important to remember that a turbine meter is a viscosity dependent device, where as the viscosity increases the linearity of the flow meter will ...

  • Omega FTB600B - page 10

    6 3 FTB600B Series Silicone Treatment Section 3 - Silicone Treatment Silicone treatment is standard for all types of the FTB600B Series series electronics. ...

  • Omega FTB600B - page 11

    7 4 FTB600B Series Infrared Sensors Section 4 - Infrared Sensor A. Supply Voltage 24 Vdc. Do not exceed 24 Vdc. Doing so can cause overheating and eventual failure of all PC boards. Printed circuit boards are non- repairable. B. Frequency Output 1. Square wave pulse, unscaled (See Figure 4-1) 2. Output impedance 75 ohms 3. Directly proportional to ...

  • Omega FTB600B - page 12

    8 FTB600B Series Infrared Sensors 4 C. Frequency Ranges for (non-cartridge models) pulses/l Model Frequency (Hz) K-Factor FTB601B 60 to 1200 36,000 FTB602B 40 to 1200 8,000 FTB603B 27 to 800 3,200 FTB604B 20 to 600 1,200 FTB605B 18.75 to 562 450 FTB606B 15 to 450 225 D. Cable Requirements 1. 20 to 22 AWG (American Wire Gauge) 2. 4 conductor-shielde ...

  • Omega FTB600B - page 13

    9 FTB600B Series Infrared Sensors 4 Figure 4-1. Output Frequency Waveforms ...

  • Omega FTB600B - page 14

    10 5 FTB600B Series Installation Section 5 - Installing the FTB600B Series in the fluid line. A. Make sure the fluid is compatible with PVDF (polyvinylidene fluoride) and meets viscosity, pressure and temperature parameters of the FTB600B Series. The fluid must also meet filtration requirements as listed in 3D. B. Install the FTB600B series in the ...

  • Omega FTB600B - page 15

    11 FTB600B Series Installation 5 Figure 5-1. Supply Voltage and Signal Output Connections ...

  • Omega FTB600B - page 16

    12 FTB600B Series Installation 5 Table 5-1. Piping Table ...

  • Omega FTB600B - page 17

    13 FTB600B Series Installation 5 Table 5-1. Piping Table Con't. ...

  • Omega FTB600B - page 18

    14 6 FTB600B Series Specifications Section 6 - Specifications Accuracy: ±3% of reading Repeatability: ±0.1% of reading Linearity: ±1% of reading Viscosity Range: 1 to 15 centistokes Working Pressure: 150 PSIG at 175°F Wetted Materials: PVDF Power Supply: 5 to 18 Vdc, 6 to 33 mA Output Signal : Unscaled square wave Pressure Drop: See Section 7 ...

  • Omega FTB600B - page 19

    15 7 FTB600B Series Pressure Drop Curves Section 7 - Pressure Drop Curves Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB601 50 0.5 0 1.0 Liters/minute kP a 1.5 2.0 45 40 35 30 25 20 15 10 5 0 ...

  • Omega FTB600B - page 20

    16 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB602 250 2.0 0 4.0 Liters/minute kP a 8 .0 6.0 10.0 200 150 100 50 0 ...

  • Omega FTB600B - page 21

    17 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB603 200 51 0 1 5 0 Liters/minute kP a 160 1 8 0 140 100 8 0 60 40 20 120 0 ...

  • Omega FTB600B - page 22

    18 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB604 200 10 20 30 0 Liters/minute kP a 160 1 8 0 140 100 8 0 60 40 20 120 0 ...

  • Omega FTB600B - page 23

    19 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB605A 160 140 120 100 8 0 60 40 20 10 20 30 40 50 60 0 Liters/minute kP a 0 ...

  • Omega FTB600B - page 24

    20 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB606A 1 8 0 160 140 120 100 8 0 60 40 20 10 20 30 40 50 60 70 8 09 0 0 Liters/minute kP a 0 ...

  • Omega FTB600B - page 25

    FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repa ...

  • Omega FTB600B - page 26

    TEMPERATURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ Wire: Thermocouple, RTD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 ⻬ Recorders, Controllers & Process Monitors 䡺 ⻬ Infrared Pyrometers PRESSURE, STRAIN AND FORCE 䡺 ⻬ Transducers & Strain Gages 䡺 ⻬ ...

Manufacturer Omega Category Stud Sensor

Documents that we receive from a manufacturer of a Omega FTB600B can be divided into several groups. They are, among others:
- Omega technical drawings
- FTB600B manuals
- Omega product data sheets
- information booklets
- or energy labels Omega FTB600B
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omega FTB600B.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omega FTB600B, service manual, brief instructions and user manuals Omega FTB600B. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omega FTB600B.

Similar manuals

A complete manual for the device Omega FTB600B, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omega FTB600B by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omega FTB600B.

A complete Omega manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omega FTB600B - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omega FTB600B, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omega FTB600B, that we can find in the current document
3. Tips how to use the basic functions of the device Omega FTB600B - which should help us in our first steps of using Omega FTB600B
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omega FTB600B
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omega FTB600B in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omega FTB600B?

Use the form below

If you did not solve your problem by using a manual Omega FTB600B, ask a question using the form below. If a user had a similar problem with Omega FTB600B it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)