    Thermidistat™ Control Installation, Start-Up, and Operating Instructions NOTE: Read the entire instruction manual before starting the installation. This symbol → indicates a change since the last issue. INDEX Page SAFETY CONSIDERATIONS .....................................................1 INTRODUCTION .......................................... ...

  • Carrier Access Thermidistat - page 2

    INSTALLATION Step 1—Thermidistat Control Location Thermidistat Control should be mounted: • Approximately 5 ft (1.5m) from floor. • Close to or in a frequently used room, preferably on an inside partitioning wall. • On a section of wall without pipes or duct work. Thermidistat Control should NOT be mounted: • Close to a window, on an outs ...

  • Carrier Access Thermidistat - page 3

    3. A2—for 2-speed air conditioner 4. H2—for 2-speed heat pump 5. dF—for 1-speed dual fuel 6. d2—for 2-speed dual fuel 7. HS—for 1-speed heat pump with Intelligent Heat Staging (3-stage auxiliary heat with 40FK, FK4C, or FV4A Series fan coils.) When this identifier disappears, normal operation begins. The MODE control should be set to OFF ...

  • Carrier Access Thermidistat - page 4

    3. Use up and down buttons to move between F and C on large display. 4. Press SET TIME/TEMP button again to flash upper small display for selection of another option, or press END to exit configuration mode. Option 4—Fan (G) On With W This selection determines whether fan (G) output is to be ON or OFF when any W (furnace or strip heat) output is ...

  • Carrier Access Thermidistat - page 5

    Option 10—Dual Fuel Equipment All dual fuel installations must be equipped with a high pressure switch to turn off compressor under a high indoor coil pressure condition. The high pressure switch protects compressor and indoor coil from overpressure which would occur if a failure or wiring error resulted in the heat pump and furnace operating at ...

  • Carrier Access Thermidistat - page 6

    will be supplied, resulting in additional outputs being turned on. If room overheats, specified outputs will not turn off, guaranteeing a sufficiently warm leaving air temperature during defrost. Tempera- ture overshoot during defrost can occur, but is almost never noticeable because of the short duration of the defrost cycle (4 minutes typical, 10 ...

  • Carrier Access Thermidistat - page 7

    3. Use up and down buttons to move between OF and ON on large display. Factory default is OF. 4. Press SET TIME/TEMP button again to flash upper small display for selection of another option, or press END to exit configuration mode. Option 17—Enable Non-Programmable Operation This option converts the programmable Thermidistat Control to a non-pro ...

  • Carrier Access Thermidistat - page 8

    TO TEST COOLING AND DEHUMIDIFICATION: Press MODE button until COOL icon turns on. Cooling begins within 10 sec and remains on for 4 minutes. If system is 2-speed, low speed comes on for first 2 minutes, followed by high speed for second 2 minutes. At the end of 4-minute run, cooling stops, and MODE reverts back to OFF. At any time during 4-minute r ...

  • Carrier Access Thermidistat - page 9

    4. Auto and Fan Humidify The 2 choices of AUTO and FAN can be selected together. This provides both functions simultaneously. 5. Humidify Off The humidify function can be turned off completely. This does not require changing existing set points. To Select Humidification (Between NORMAL, FAN, AUTO, FAN and AUTO, or OFF) (See Table 4.) Press HUMIDITY ...

  • Carrier Access Thermidistat - page 10

    humidity removal is desired, this should be done, if possible. Fan coils have the capability of removing this off delay, furnaces do not. On FK or FV Fan Coils, set delay tap to 0/0. On standard fan coils, a jumper can be cut to disable off delay. Refer to fan coil Installation Instructions for details. If FAN is set for continuous operation (fan O ...

  • Carrier Access Thermidistat - page 11

    Vacation Dehumidification Normal Dehumidify, Cool to Dehumidify, and Dehumidify OFF, are all available in vacation mode, and selection of 1 of these can be different from that of occupied. Vacation dehumidification selection and set points are remembered the next time vacation is used. Cool to dehumidify operates slightly differently, allowing the ...

  • Carrier Access Thermidistat - page 12

    THERMIDIST A T CONTROL CONFIGURA TION RECORD Date Owner/Operator A) Hardware Configuration Switch A ____ AC/HP Select. (OFF = AC) Switch B ____ 1 or 2-Speed Compressor . (OFF = 1-Speed) Switch C ____ Smar t Recov ery . (OFF = Enable) Switch D ____ Installer T est. (OFF = Disab le) Thermidistat Model No. B) Mode Settings ____ Hold (On or Off) ____ M ...

Fabbricante Carrier Access Categoria Thermostat

I documenti che otteniamo dal fabbricante del dispositivoCarrier Access Thermidistat possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Carrier Access
- manuali per l’uso Thermidistat
- schede prodotto Carrier Access
- opuscoli
- o etichette energetiche Carrier Access Thermidistat
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Carrier Access Thermidistat.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Carrier Access Thermidistat, manuali di manutenzione, brevi manuali o manuali utente Carrier Access Thermidistat. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Carrier Access Thermidistat.

Manuali per l’uso simili

Manuale completo del dispositivo Carrier Access Thermidistat, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Carrier Access Thermidistat dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Carrier Access Thermidistat.

Il manuale per l’uso completo Carrier Access, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Carrier Access Thermidistat - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Carrier Access Thermidistat, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Carrier Access Thermidistat che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Carrier Access Thermidistat - che ci dovrebbe aiutare nei primi passi durante l'uso Carrier Access Thermidistat
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Carrier Access Thermidistat
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Carrier Access Thermidistat in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Carrier Access Thermidistat?

Utilizza il modulo sottostante

Se non hai risolto il problema con Carrier Access Thermidistat con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Carrier Access Thermidistat è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)