    24/96 AD-DA Co nv erter Manual Model 2053 ...

  • Sound Performance Lab 2053 - page 2

    Manual 24/96 AD-DA Converter 2053 2 24/96 AD-DA Converter 2053 V ersion 1.0 – 8/2000 The information in this document has been carefully verified and is assumed to be correct. However Sound Performance Lab (SPL) reserves the right to modify the product described in this manual at any time. Changes without notice. This document is the propert y of ...

  • Sound Performance Lab 2053 - page 3

    Con t en t s 3 24/96 AD-DA Converter 2053 Security Advices ................................................................ 4 Product Description ......................................................... 4 Mounting General Information ................................................. 5 Steps 1 and 2 ................................................. ...

  • Sound Performance Lab 2053 - page 4

    Security Advices 4 24/96 AD-DA Converter 2053 • Please consider referring the installation of the unit operating the converter the safety information in the corresponding operation instruction. • Please carr y out the self-installation only as descri- bed from page 5. In case of queries please contac t an expert. The SPL conv erter module 2053 ...

  • Sound Performance Lab 2053 - page 5

    5 24/96 AD-DA Converter 2053 External synchronization: For synchronization with external sources, AES-data or W ord-Clock signals can be used as sync sources. Alternatively the A/D conv erter can be synchronized to the data adjacent to the D/A converter . For int ernal/external synchroniza- tion please refer to the chapter "Operation", fr ...

  • Sound Performance Lab 2053 - page 6

    Mounting Steps 1 and 2 6 24/96 AD-DA Converter 2053 Step 1: Please put the converter module as illust- rated on the unit top and remov e the screws of the cover from the back of the upgrade unit. Step 2: Please remove the mounting of the wiring on the back of the cover (eventually cut off the silicon). Socket Socket Connector ...

  • Sound Performance Lab 2053 - page 7

    Mounting Steps 3 and 4 7 24/96 AD-DA Converter 2053 Step 3: Connect the cable carefully , without turning, to the socket of the converter . Guideways on socket and plug exclude a wrong connection. Step 4: Put the converter , as illustrated, without lateral turning in the unit (circuit board above , connection sockets on the head) and connect it wit ...

  • Sound Performance Lab 2053 - page 8

    C onnections 8 24/96 AD-DA Converter 2053 The conv erter module provides analog, balanced XLR outputs ( 1 ), digital XLR I/Os (AES/EBU) ( 2 ) and digital S/P-DIF I/Os ( 3 ). In case of using the S/P-DIF output as a WC/AES SYNC input, the S/P-DIF output is no longer available . Important: please never use AES- and S/P- DIF digital inputs simultaneou ...

  • Sound Performance Lab 2053 - page 9

    C onnections 9 24/96 AD-DA Converter 2053 Digital I/Os AES/EBU: Inputs and outputs according to the AES/EBU specification for the connection of all digital units specified in accordance to AES/EBU. S/P-DIF: Alternatively to the digital XLR-sockets, the S/P-DIF I/Os can be used for the connection of digital units. The S/P-DIF output (=WC/AES SYNC IN ...

  • Sound Performance Lab 2053 - page 10

    Operation 10 24/96 AD-DA Converter 2053 AD MODE Switch The AD MODE switch is used to set the desired bit mode and sample rate. The follo- wing list explains the respective switch positions: 16 Bit Mode E = AES Ext. Synchronization to AES clock D = DA Synchronization zum D/A conv erter C = WC Ext. Synchronization to wor d clock B = 48 Int. Synchroni ...

  • Sound Performance Lab 2053 - page 11

    Operation 11 24/96 AD-DA Converter 2053 External Synchronization External Synchronization (Connection via W/C-AES SYNC INPUT ) is required when several signals must be brought together within a chain of digital units, e.g . when connecting several digital units at one console. Since the sample frequencies are never exactly iden- tical, not synchron ...

  • Sound Performance Lab 2053 - page 12

    Applications 12 24/96 AD-DA Converter 2053 CHANNEL ONE: Using both conv er ters Referring to the CHANNEL ONE, the separate use of both converters can be for example the con version of digital signals independent from the A/D converter and to reproduce them in best tonal quality on louds- peakers or headphones. Example: High-quality con version of a ...

  • Sound Performance Lab 2053 - page 13

    Applications 13 24/96 AD-DA Converter 2053 Monitoring in 24Bit/96kHz A high standard of monitoring is necessary for judging the recording quality . Therefor e all digital signals have to be con verted into analog signals to allow reproduction on loudspeakers or headphones. The A/D conv erter stage is equipped with high- quality components and ensur ...

  • Sound Performance Lab 2053 - page 14

    Applications 14 24/96 AD-DA Converter 2053 Example 1: Processing a sampler's signal Connect the output of the sampler via AES/EBU or S/P-DIF interface with the input of the converter . The adjustment described in the section above now allows to process the sampler's signal. If the processed signal is to be returned digitally converted to ...

  • Sound Performance Lab 2053 - page 15

    Specifications 15 24/96 AD-DA Converter 2053 A/D Con ver ter W ordwidth ................................... 24 Bit Reduced W ordwidth ................ 16 Bit Dither ............................................ triangular Internal sample rates .............. 44.1/48/88.2/96 kHz External sample rates .............. 32-96 kHz Sync sources ............ ...

  • Sound Performance Lab 2053 - page 16

    Block Diagram 16 24/96 AD-DA Converter 2053 ...

  • Sound Performance Lab 2053 - page 17

    Measurements 17 24/96 AD-DA Converter 2053 D/A: THD & N abov e input lev el D/A: THD & N @ 1 kHz FFT ...

  • Sound Performance Lab 2053 - page 18

    Measurements 18 24/96 AD-DA Converter 2053 A/D: THD & N above input le v el A/D: THD & N @ 1 kHz FFT ...

  • Sound Performance Lab 2053 - page 19

    Wa r ra nt y 19 24/96 AD-DA Converter 2053 SPL electronics GmbH (hereafter called SPL) products are warranted only in the country where purchased, through the authorized SPL distri- butor in that country, against defects in material or workmanship. The specific period of this limited warranty shall be that which is described to the original retail ...

  • Sound Performance Lab 2053 - page 20

    Sound Performance Lab Sohlweg 55 D-41372 Niederkruechten Germany T el. +49 • 2163 • 9834-0, F ax -20 info@soundperformancelab.com www .soundperformancelab.com 24/96 AD-DA Converter , Model 2053 ...

Fabbricante Sound Performance Lab Categoria Welding System

I documenti che otteniamo dal fabbricante del dispositivoSound Performance Lab 2053 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Sound Performance Lab
- manuali per l’uso 2053
- schede prodotto Sound Performance Lab
- opuscoli
- o etichette energetiche Sound Performance Lab 2053
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Sound Performance Lab 2053.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Sound Performance Lab 2053, manuali di manutenzione, brevi manuali o manuali utente Sound Performance Lab 2053. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Sound Performance Lab 2053.

Manuale completo del dispositivo Sound Performance Lab 2053, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Sound Performance Lab 2053 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Sound Performance Lab 2053.

Il manuale per l’uso completo Sound Performance Lab, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Sound Performance Lab 2053 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Sound Performance Lab 2053, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Sound Performance Lab 2053 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Sound Performance Lab 2053 - che ci dovrebbe aiutare nei primi passi durante l'uso Sound Performance Lab 2053
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Sound Performance Lab 2053
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Sound Performance Lab 2053 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Sound Performance Lab 2053?

Utilizza il modulo sottostante

Se non hai risolto il problema con Sound Performance Lab 2053 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Sound Performance Lab 2053 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)