Manuale per l’uso Invacare IRC5PO2W

32 pagine 1.77 mb
Scarica

Vai alla pagina of 32

Summary
  • Invacare IRC5PO2W - page 1

    Dealer: This manual MUST be given to the end user of this product. User: BEFORE using this product, read this manual and save for future reference. User Manual For more information regarding Invacare products, parts, and services, please visit www.invacare.com Perfecto 2 ™ Series Oxygen Concentrators without SensO 2 ®, Oxygen Concentrators with ...

  • Invacare IRC5PO2W - page 2

    WARNING Perfecto 2 ™ Series 2 Part No 114348 2  WARNING DO NOT USE THIS PRODUCT OR ANY AVAILABLE OPTIONAL EQUIPMENT WITHOUT FIRST COMPLETELY READING AND UN DERSTANDING THESE INSTRUCTIONS AND ANY ADDITIONAL INSTRUCTIONAL MATERIAL SUCH AS OWNER’S MANUALS, SERVICE MANUALS OR INSTRUCTION SHEETS SUPPLIED WITH THIS PRODUCT OR OPTIONAL EQUIPMENT. I ...

  • Invacare IRC5PO2W - page 3

    TABLE OF CONTENTS Part No 1143482 3 Perfecto 2 ™ Series Table of Contents ACCESSORIES .................................................. 2 SPECIAL NOTES ............................................... 4 LABEL LOCATION ............................................ 6 SECTION 1—GENERAL GUIDELINES .................. 7 To Reduce the Risk of Burns, El ...

  • Invacare IRC5PO2W - page 4

    SPECIAL NOTES Perfecto 2 ™ Series 4 Part No 114348 2 SPECIAL NOTES Signal  words  are  used  in  this  manual  and  apply  to  hazards  or  unsafe  practices  which  could  result  in  personal  injury  or  property  damage.  Refer  to  the  following  table  for ...

  • Invacare IRC5PO2W - page 5

    SPECIAL NOTES Part No 1143482 5 Perfecto 2 ™ Series CAUTION “Caution:  Federal  law  restricts  this  device  to  sale  or  rental  by  or  on  order  of  a  physician,  or  any  other  practitioner  licensed  by  the  law  of  the  State  in  which  he/sh ...

  • Invacare IRC5PO2W - page 6

    LABEL LOCATION Perfecto 2 ™ Series 6 Part No 114348 2 LABEL LOCATION FOR OPERA TING INSTRUCTIONS or ALARMS (See Operator’s Manual) DANGER - ELECTRIC SHOCK DANGER - RISK OF FIRE NO SMOKING - Keep ALL sources of ignition out of the room in which this product is located and away from areas where o xygen is being delivered. T extiles, oil and other ...

  • Invacare IRC5PO2W - page 7

    SECTION 1—GENERAL GUIDELINES Part No 1143482 7 Perfecto 2 ™ Series SECTION 1—GENERAL GUIDELINES In  order  to  ensure  the  safe  installation,  assembly  and  operation  of  the  Pe r f e c t o 2  concentrator  these  instructions  MUST  be  followed.  WARNING This  section  cont ...

  • Invacare IRC5PO2W - page 8

    SECTION 1—GENERAL GUIDELINES Perfecto 2 ™ Series 8 Part No 114348 2 Operating Information For  optimum  performance,  Inv acare  recommends  that  each  concentrator  be  on  and  runni ng  for  a  minimum  of  30  minutes  at  a  ti me.  Shorter  periods  of  operation  ...

  • Invacare IRC5PO2W - page 9

    SECTION 1—GENERAL GUIDELINES Part No 1143482 9 Perfecto 2 ™ Series Other  devices  may  experience  interference  from  ev en  the  low  levels  of  electromagnetic  emissions  permitted  by  the  above  standards.  To  determine  if  the  emissions  from  the  Pe r f e ...

  • Invacare IRC5PO2W - page 10

    SECTION 2—FEATURES Perfecto 2 ™ Series 10 Part No 1143482 SECTION 2—FEATURES Oxygen Outlet Flowmeter Oxygen Purity Indicator Lights / Fault an d Power Indicator Lights Power Switch Circuit Breaker Elapsed Time Meter Cabinet Filter REAR VIEW ACCESSORIES (NOT SHOWN): PreciseRX™ Pedi atric Humidifier/Flowmeter Accessory - IRCPF16 (Perfecto 2 5 ...

  • Invacare IRC5PO2W - page 11

    SECTION 3—HANDLING Part No 1143482 11 Perfecto 2 ™ Series SECTION 3—HANDLING The  concentrator  should  AL W A YS  be  kept  in  the  upright  position  to  prevent  cabinet  damage  while  being  transported.  If  the  concentrator  is  to  be  reshipped  by  common ? ...

  • Invacare IRC5PO2W - page 12

    SECTION 4—TYPICAL PRODUCT PARAMETERS Perfecto 2 ™ Series 12 Part No 1143482 SECTION 4—TYPICAL PRODUCT PARAMETERS Electrical Requirements: 120 VAC ± 10% (132 VAC/10 8 VAC), 60 Hz Rated Current Input: 3 A Sound Level: 43 ± 2 dBA Average for Perfecto 2 Models and Perfecto 2 V Model 40 ± 2 dBA Average for Perfecto 2 W Models Altitude: All Perf ...

  • Invacare IRC5PO2W - page 13

    SECTION 4—TYPICAL PRODUCT PARAMETERS Part No 1143482 13 Perfecto 2 ™ Series Change in maximum recommended flow when back pressure of 7kPa is applied: 0.7 L/min Filters: Cabinet, Outlet HEPA and Compressor Inlet Safety System: Current overload or line surge shutdown. H igh temperature compressor shutdown. High Pressure Alarm w/compressor shutdow ...

  • Invacare IRC5PO2W - page 14

    SECTION 4—TYPICAL PRODUCT PARAMETERS Perfecto 2 ™ Series 14 Part No 1143482 *NOTE:  Stated  concentration  levels  achieved  after  initial  warm ‐ up  period  (appr oximately  30  minutes). Placement: No closer than three inche s from any wall , furniture, draperies, or similar surfaces. Tubing: 7 ft cannula ...

  • Invacare IRC5PO2W - page 15

    SECTION 5—OPERATING INSTRUCTIONS Part No 1143482 15 Perfecto 2 ™ Series SECTION 5— OPERATING INSTRUCTIONS Introduction Yo u r  oxygen  concentrator  is  intended  for  individual  use  indoors.  It  is  an  electronically  operated  device  that  separates  oxygen  from  room  air . ...

  • Invacare IRC5PO2W - page 16

    SECTION 5—OPERATING INSTRUCTIONS Perfecto 2 ™ Series 16 Part No 1143482 Set Up Plug in Power Cord Plug  in  pow er  cord  to  an  electrical  outlet. Connect Humidifier (If So Prescribed)  WARNING DO  NOT  overfill  humidifier . DO  NOT  reverse  the  oxygen  input  and  output  connectio ...

  • Invacare IRC5PO2W - page 17

    SECTION 5—OPERATING INSTRUCTIONS Part No 1143482 17 Perfecto 2 ™ Series FIGURE 5.2 Humidifer Bottle Adapter 5. Attach  the  humidifier  bottle  adapter  to  the  humidifier  bottle  by  turning  the  wing  nut  on  the  humidifier  bottle  counterclockwise  until  it  is  securel ...

  • Invacare IRC5PO2W - page 18

    SECTION 5—OPERATING INSTRUCTIONS Perfecto 2 ™ Series 18 Part No 1143482 FIGURE 5.3 Humidifier Compartmen t Power Switch NOTE:  For  this  pr ocedure,  refe r  to  FIGURE  5.4. 1. Press  pow er  sw itch  to  on  position.  All  the  panel  lights  and  the  audible  alarm  will  c ...

  • Invacare IRC5PO2W - page 19

    SECTION 5—OPERATING INSTRUCTIONS Part No 1143482 19 Perfecto 2 ™ Series Flowrate NOTE:  For  this  procedure,  refe r  to  FIGURE  5.5  on  page 20. 1. T urn  the  flowrate  knob  to  the  setting  prescribed  by  you r  physician  or  therapist. CAUTION Never  set  the  fl ...

  • Invacare IRC5PO2W - page 20

    SECTION 5—OPERATING INSTRUCTIONS Perfecto 2 ™ Series 20 Part No 1143482 FIGURE 5.5 Flowrate Front Panel Indicators - Units with SensO 2 The  SensO 2  feature  monitors  the  purity  of  oxygen  generated  by  the  oxygen  concentrator .  If  purity  falls  below  factory  preset  standard ...

  • Invacare IRC5PO2W - page 21

    SECTION 5—OPERATING INSTRUCTIONS Part No 1143482 21 Perfecto 2 ™ Series Initial Startup of the Concentrator NOTE:  Concentrator  may  be  used  during  the  initial  sta rt  warm ‐ up  time  (approximately  30  min.)  while  waiting  for  the  O 2  purity  to  rea c h  maximum. ...

  • Invacare IRC5PO2W - page 22

    SECTION 5—OPERATING INSTRUCTIONS Perfecto 2 ™ Series 22 Part No 1143482 Initial Startup of the Concentrator NOTE:  Concentrator  may  be  used  during  the  initial  sta rt  warm ‐ up  time  (approximately  30  min).  O 2  purity  will  build  to  a  maximum  during  this  p ...

  • Invacare IRC5PO2W - page 23

    SECTION 6—MAINTENANCE Part No 1143482 23 Perfecto 2 ™ Series SECTION 6—MAINTENANCE  WARNING The  Invacare  concentrators  are  specifically  designed  to  minimize  routine  preventiv e  mainte nance.  Only  qualified  personnel  should  perform  preventiv e  maintenance  on  the  ...

  • Invacare IRC5PO2W - page 24

    SECTION 6—MAINTENANCE Perfecto 2 ™ Series 24 Part No 1143482 2. Clean  the  cabinet  filter  with  a  va c u u m  cleaner  or  wa s h  in  w arm  soapy  wa t e r  and  rinse  thoroughly . 3. Dry  the  filter  thoroughly  before  reinstallation. FIGURE 6.1 Cleaning the Cabinet Filter ...

  • Invacare IRC5PO2W - page 25

    SECTION 6—MAINTENANCE Part No 1143482 25 Perfecto 2 ™ Series FIGURE 6.2 Preventi ve Maintenance Record ON EACH INSPECTION MODEL NO. I R C SERIAL NO. PREVENTIVE MAINTENANCE RECORD Record Date of Service Record Elapsed Hours On Hour Meter Clean Cabinet Filter(s) Check Prescribed L/min. Flow Rate EVERY 4,380 HOURS Check Oxygen Concentration (UNITS ...

  • Invacare IRC5PO2W - page 26

    SECTION 7—TROUBLESHOOTING GUIDE Perfecto 2 ™ Series 26 Part No 1143482 SECTION 7—TROUBLESHOOTING GUIDE SYMPTOM: PROBABLE CAUSE: SOLUTION: Alarm: Short beeps, long pause Concentrator not operating, power switch On. Beep......Beep. ..... Main Power Loss: 1. Power cord not plugged in. 1. Insert plug in to outlet. 2. No power at outlet. 2 . Inspe ...

  • Invacare IRC5PO2W - page 27

    SECTION 7—TROUBLESHOOTING GUIDE Part No 1143482 27 Perfecto 2 ™ Series YELLOW or RED light Illuminated. Alarm: Continuo us On RED light only. * Only applies to IRC5PO2. 1. Low oxygen purity.* 1. Clean or Replace filters. 2. Kinked or blocked tubing, cannula or humidifier.* 2. Inspect for kinks or blockages. Correct, clean or replace item. Once ...

  • Invacare IRC5PO2W - page 28

    NOTES Perfecto 2 ™ Series 28 Part No 1143482 NOTES ...

  • Invacare IRC5PO2W - page 29

    NOTES Part No 1143482 29 Perfecto 2 ™ Series NOTES ...

  • Invacare IRC5PO2W - page 30

    NOTES Perfecto 2 ™ Series 30 Part No 1143482 NOTES ...

  • Invacare IRC5PO2W - page 31

    LIMITED WARRANTY Part No 1143482 31 Perfecto 2 ™ Series LIMITED WARRANTY NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURE D AFTER JULY 4, 197 5. This warranty is extended only to th e original purchaser who purchases this product when new and unused from Invacare Corporation or a dealer. This ...

  • Invacare IRC5PO2W - page 32

    LIMITATIONS AND EXCLUSIONS: THE FOREGOING WARRANTY SHALL NOT APPLY TO PRODUCTS SUBJECTED TO NEGLIGENCE, ACCIDENT, IMPROPER OPERATION, MAINTENANCE OR STORAGE, SOOT OR SMOKE-FILLED ENVI RONMENTS, OR OTHER THAN NORMAL APPLICATION, USE OR SERVICE, OR TO PRODUCTS MODIFIED WITHOUT INVACARE CORPORATION'S EXPRESS WRITTEN CONSENT (INCLUDIN G, BUT NOT L ...

Fabbricante Invacare Categoria Oxygen Equipment

I documenti che otteniamo dal fabbricante del dispositivoInvacare IRC5PO2W possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Invacare
- manuali per l’uso IRC5PO2W
- schede prodotto Invacare
- opuscoli
- o etichette energetiche Invacare IRC5PO2W
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Invacare IRC5PO2W.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Invacare IRC5PO2W, manuali di manutenzione, brevi manuali o manuali utente Invacare IRC5PO2W. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Invacare IRC5PO2W.

Manuali per l’uso simili

Manuale completo del dispositivo Invacare IRC5PO2W, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Invacare IRC5PO2W dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Invacare IRC5PO2W.

Il manuale per l’uso completo Invacare, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Invacare IRC5PO2W - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Invacare IRC5PO2W, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Invacare IRC5PO2W che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Invacare IRC5PO2W - che ci dovrebbe aiutare nei primi passi durante l'uso Invacare IRC5PO2W
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Invacare IRC5PO2W
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Invacare IRC5PO2W in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Invacare IRC5PO2W?

Utilizza il modulo sottostante

Se non hai risolto il problema con Invacare IRC5PO2W con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Invacare IRC5PO2W è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)