  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 1

    SE95033 Rev . 5 1333 East 179th S t., Cleveland, Ohio, U.S.A. 441 10 Phone: (216) 481-4900 Fax: (216) 481-3782 Visit our web site at www .clevelandrange.com Operators Manual Installation, Operation & Service Skillets Clev elan d ™ Enodis OPEN BASE & MODULAR GAS SKILLETS - MODELS SGL-30-TR SGM-30-TR SGL-40-TR SGM-40-TR ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 2

    FOR THE USER IMPOR T ANT Post in a prominent location, instructions to be followed in the event the user smells gas. This information shall be obtained by consulting your local gas supplier . Keep appliance area free and clear from combustibles. Do not obstruct the flow of combustion and ventilation air . All service must be performed by a qualifie ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 3

    ✘ 1 2 ✘ SER VICING IMPOR T ANT CAUTION DANGER GAS APPLIANCES For your safety K eep hands and utensils aw ay from moving parts and pinch points. W ear protective equipment when discharging hot product. Shut off power at main fuse disconnect prior to ser vicing. Inspect unit daily f or proper operation. Surf aces may be e xtremely hot! Use protec ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 4

    GENERAL Installation of the unit must be accomplished by qualified installation personnel working to all applicable local and national codes. Improper installation of unit could cause injury or damage. This equipment is built to comply with applicable standards for manufactur ers. Included among those approval agencies ar e: UL, A.G.A., NSF , ASME/ ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 5

    INST ALLA TION KEEP THE APPLIANCE AREA FREE AND CLEAR OF COMBUSTIBLE MA TERIALS. 1. Carefully r emove unit from carton or crate. Remove any packing material from unit. 2. A protective material has been applied to the stainless steel panels. NO TE : This material must be removed immediately after installation, as heat will melt the material and make ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 6

    CONTROL P ANEL OPERA TING INSTRUCTIONS ITEM # DESCRIPTION FUNCTION 1. On-Off Switch Main power switch for unit. 2. Power Indicator Light (Red) Indicates power is on. 3. Heat Indicator Light (Y ellow) T urns ON when system is calling for heat and OFF when system is satisfied. 4. T emperature Dial Regulates the surface temperature of the pan. 5. Powe ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 7

    ST ART UP PROCEDURE This appliance has been factory tested and adjusted under ideal conditions but, rough handling, low gas pressur e, altitude or variations in gas characteristics may requir e fine adjustment. All units are equipped with fixed orifices and do not requir e primar y air adjustment. LIGHTING INSTRUCTIONS NO TE : This appliance is equ ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 8

    CARE AND CLEANING Cooking equipment must be cleaned regularly to maintain its fast, efficient cooking performance and to ensure its continued safe, r eliable operation. The best time to clean is shortly after each use (allow unit to cool to a safe temperature). W ARNINGS ➩ Do not use detergents or cleansers that are chloride based or contain quat ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 9

    ST AINLESS STEEL EQUIPMENT CARE AND CLEANING (Suppied courtesy of Nafem. For more information visit their web site at www .nafem.org) Contrary to popular belief, stainless steels ARE susceptible to rusting. Corrosion on metals is everywhere. It is r ecognized quickly on iron and steel as unsightly yellow/orange rust. Such metals are called “activ ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 10

    2 6 6 3 10 7 4 12 11 9 10 2 8 5 1 1 6 6 3 7 4 Hydraulic Jack Assemb ly KE000772 F or units built prior to Februar y 2005 (replaces old Jac k #s SK2381000 & SK00403) Hydraulic Jack Assemb ly KE000523 F or units built after F ebr uar y 2005 HYDRAULIC JACK ASSEMBLIES ITEM NO . P ART NO . DESCRIPTION QTY . 1 KE600526 HYDRAULIC CYLINDER . . . . . . ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 11

    HYDRAULIC JACK ASSEMBLIES - HAND TIL T ITEM NO . P ART NO . DESCRIPTION QTY . 1 2381000 HYDRAULIC JACK ASSEMBL Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 (NO LONGER A V AILABLE, USE KE000772) 5 F A95007-7 RET AINING RING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 12

    ACTUA TOR ASSEMBL Y - POWER TIL T (used prior to January , 2000) ITEM NO . P ART NO . DESCRIPTION QTY . 1. SK2346100 ACTUA TOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. SK2337499 ACTUA TOR MOUNTING BRACKET ASSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. SK23576 ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 13

    ACTUA TOR ASSEMBL Y - POWER TIL T (used after Jan uar y , 2000) 7 7 6 7 9 8 9 7 3 4 4 1 2 5 5 10 11 1 3 12 15 14 ITEM NO . P ART NO . DESCRIPTION QTY . 1. SK2346100 ACTUA TOR ASSY ., COMPLETE WITH ITEM 2 . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE003242 ACTUA TOR ASSY ., WITH MANUAL OVERRIDE, COMPLETE WITH ITEMS 2 & 3 . . .1 2. SK23 ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 14

    New (added February 2005) KE600452 (Strainer) FI00351 (Bushing) FI05318-1 (Elbow , hose barb) ITEM NO . P ART NO . DESCRIPTION QTY . 1 2379100 HYDRAULIC ADAPTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2 2379600 HYDRAULIC HOSE ASSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 15

    ITEM NO . P ART NO . DESCRIPTION QTY . 1 2474101 POWER SWITCH (240V , USED AFTER FEBRUARY 2001) . . . . . . . . . . . . . . . . . . . . . .1 2474100 POWER SWITCH (USED AFTER FEBRUARY 2001) . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2343500 POWER SWITCH (USED PRIOR TO FEBRUAR Y 2001) . . . . . . . . . . . . . . . . . . . . . . . .1 2 234 ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 16

    ITEM NO . P ART NO . DESCRIPTION QTY . 1. SE00119 T HERM OSTA T BOAR D ASSEMBLY (INCLUDES 2 - 14) 1 2. SK2142002 TEMPERA TURE SENSOR BOARD 1 3. SK2159300 INSULA TOR, THERMOST A T 1 4. SK2498399 P OTEN TIO ME T ER SHAFT ASSEMBLY (INCLUDES 5-10) 1 5. SK2167200 RET AINING RING, SP-NR #R1000-25 1 6. SK2167100 W ASHER, BOWED/SPRING 1 7. SK2167300 P ANEL ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 17

    ITEM NO . P ART NO . DESCRIPTION QTY . 1 KE53838-32 TRANSFORMER - POWER TIL T - 110-120V/60 . . . . . . . . . . . . . . . . . . . . . . . . .1 KE53838-31 TRANSFORMER - POWER TIL T - 208-240/60 . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE53838-30 TRANSFORMER - POWER TIL T - 208-240/50 . . . . . . . . . . . . . . . . . . . . . . . . . .1 K ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 18

    ITEM NO. P ART NO. DESCRIPTION QTY . 1 KE55069-7 HI-LIMIT 1 2 2353900 BULB CLAMP 1 3 2354099 BULB SHIELD ASSY 1 4 F95 NUT 1 5 2345100 RTD SENSOR 1 6 2344900 SHIELD LINER 1 7 2345000 SHIELD 1 PLA TE ASSEMBL Y (used prior to January , 2000) ITEM NO. P ART NO. DESCRIPTION QTY . 1 F A21053 LOCK NUT 1/2-13 S.S. . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 19

    SPRING ASSEMBL Y ITEM NO . P ART NO . DESCRIPTION QTY . 1 2452300 SPRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2 2381700 TURNBUCKLE BODY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 3 2374900 CONNECTING ROD R/H ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 20

    ITEM NO . P ART NO . DESCRIPTION QTY . 1 2359300 BACK TOP MOUNTING BRACKET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2 2360101 REAR COMBUSTION SEAL - 40 GAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2360100 REAR COMBUSTION SEAL - 30 GAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 21

    ITEM NO . P ART NO . DESCRIPTION QTY . 1 2373100 BURNER (NA T . GAS) . . . . . . . . . . . . . . . . . . . . . . . . . . .7 for 30 gal., 10 for 40 gal. KE02410 BURNER (LP GAS) . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 for 30 gal., 10 for 40 gal. 2 KE55277-1 ORIFICE, (NA T . GAS), 2000 FT . . . . . . . . . . . . . . . . . . .7 for 30 ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 22

    N OT E : ANY MAINTENANCE OR SERVICE INVOL VING DISSASSEMBL Y OF COMPONENTS SHOULD BE MADE BY A QUALIFIED SERVICE TECHNICIAN. ENSURE GAS, ELECTRICAL AND W A TER SUPPL Y (IF APPLICABLE) TO THE APPLIANCE ARE SHUT OFF Y ou have purchased the finest commer cial cooking equipment available anywhere. Like any other fine, precision built piece of equipment ...

Fabbricante Cleveland Categoria Fryer

I documenti che otteniamo dal fabbricante del dispositivoCleveland Open Base & Modular Gas Skillet SGL-30-TR possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Cleveland
- manuali per l’uso Open Base & Modular Gas Skillet SGL-30-TR
- schede prodotto Cleveland
- opuscoli
- o etichette energetiche Cleveland Open Base & Modular Gas Skillet SGL-30-TR
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Cleveland Open Base & Modular Gas Skillet SGL-30-TR.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Cleveland Open Base & Modular Gas Skillet SGL-30-TR, manuali di manutenzione, brevi manuali o manuali utente Cleveland Open Base & Modular Gas Skillet SGL-30-TR. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Cleveland Open Base & Modular Gas Skillet SGL-30-TR.

Manuale completo del dispositivo Cleveland Open Base & Modular Gas Skillet SGL-30-TR, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Cleveland Open Base & Modular Gas Skillet SGL-30-TR dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Cleveland Open Base & Modular Gas Skillet SGL-30-TR.

Il manuale per l’uso completo Cleveland, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Cleveland Open Base & Modular Gas Skillet SGL-30-TR - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Cleveland Open Base & Modular Gas Skillet SGL-30-TR, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Cleveland Open Base & Modular Gas Skillet SGL-30-TR che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Cleveland Open Base & Modular Gas Skillet SGL-30-TR - che ci dovrebbe aiutare nei primi passi durante l'uso Cleveland Open Base & Modular Gas Skillet SGL-30-TR
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Cleveland Open Base & Modular Gas Skillet SGL-30-TR
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Cleveland Open Base & Modular Gas Skillet SGL-30-TR in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Cleveland Open Base & Modular Gas Skillet SGL-30-TR?

Utilizza il modulo sottostante

Se non hai risolto il problema con Cleveland Open Base & Modular Gas Skillet SGL-30-TR con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Cleveland Open Base & Modular Gas Skillet SGL-30-TR è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)