    SE95033 Rev . 5 1333 East 179th S t., Cleveland, Ohio, U.S.A. 441 10 Phone: (216) 481-4900 Fax: (216) 481-3782 Visit our web site at www .clevelandrange.com Operators Manual Installation, Operation & Service Skillets Clev elan d ™ Enodis OPEN BASE & MODULAR GAS SKILLETS - MODELS SGL-30-TR SGM-30-TR SGL-40-TR SGM-40-TR ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 2

    FOR THE USER IMPOR T ANT Post in a prominent location, instructions to be followed in the event the user smells gas. This information shall be obtained by consulting your local gas supplier . Keep appliance area free and clear from combustibles. Do not obstruct the flow of combustion and ventilation air . All service must be performed by a qualifie ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 3

    ✘ 1 2 ✘ SER VICING IMPOR T ANT CAUTION DANGER GAS APPLIANCES For your safety K eep hands and utensils aw ay from moving parts and pinch points. W ear protective equipment when discharging hot product. Shut off power at main fuse disconnect prior to ser vicing. Inspect unit daily f or proper operation. Surf aces may be e xtremely hot! Use protec ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 4

    GENERAL Installation of the unit must be accomplished by qualified installation personnel working to all applicable local and national codes. Improper installation of unit could cause injury or damage. This equipment is built to comply with applicable standards for manufactur ers. Included among those approval agencies ar e: UL, A.G.A., NSF , ASME/ ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 5

    INST ALLA TION KEEP THE APPLIANCE AREA FREE AND CLEAR OF COMBUSTIBLE MA TERIALS. 1. Carefully r emove unit from carton or crate. Remove any packing material from unit. 2. A protective material has been applied to the stainless steel panels. NO TE : This material must be removed immediately after installation, as heat will melt the material and make ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 6

    CONTROL P ANEL OPERA TING INSTRUCTIONS ITEM # DESCRIPTION FUNCTION 1. On-Off Switch Main power switch for unit. 2. Power Indicator Light (Red) Indicates power is on. 3. Heat Indicator Light (Y ellow) T urns ON when system is calling for heat and OFF when system is satisfied. 4. T emperature Dial Regulates the surface temperature of the pan. 5. Powe ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 7

    ST ART UP PROCEDURE This appliance has been factory tested and adjusted under ideal conditions but, rough handling, low gas pressur e, altitude or variations in gas characteristics may requir e fine adjustment. All units are equipped with fixed orifices and do not requir e primar y air adjustment. LIGHTING INSTRUCTIONS NO TE : This appliance is equ ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 8

    CARE AND CLEANING Cooking equipment must be cleaned regularly to maintain its fast, efficient cooking performance and to ensure its continued safe, r eliable operation. The best time to clean is shortly after each use (allow unit to cool to a safe temperature). W ARNINGS ➩ Do not use detergents or cleansers that are chloride based or contain quat ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 9

    ST AINLESS STEEL EQUIPMENT CARE AND CLEANING (Suppied courtesy of Nafem. For more information visit their web site at www .nafem.org) Contrary to popular belief, stainless steels ARE susceptible to rusting. Corrosion on metals is everywhere. It is r ecognized quickly on iron and steel as unsightly yellow/orange rust. Such metals are called “activ ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 10

    2 6 6 3 10 7 4 12 11 9 10 2 8 5 1 1 6 6 3 7 4 Hydraulic Jack Assemb ly KE000772 F or units built prior to Februar y 2005 (replaces old Jac k #s SK2381000 & SK00403) Hydraulic Jack Assemb ly KE000523 F or units built after F ebr uar y 2005 HYDRAULIC JACK ASSEMBLIES ITEM NO . P ART NO . DESCRIPTION QTY . 1 KE600526 HYDRAULIC CYLINDER . . . . . . ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 11

    HYDRAULIC JACK ASSEMBLIES - HAND TIL T ITEM NO . P ART NO . DESCRIPTION QTY . 1 2381000 HYDRAULIC JACK ASSEMBL Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 (NO LONGER A V AILABLE, USE KE000772) 5 F A95007-7 RET AINING RING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 12

    ACTUA TOR ASSEMBL Y - POWER TIL T (used prior to January , 2000) ITEM NO . P ART NO . DESCRIPTION QTY . 1. SK2346100 ACTUA TOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. SK2337499 ACTUA TOR MOUNTING BRACKET ASSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. SK23576 ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 13

    ACTUA TOR ASSEMBL Y - POWER TIL T (used after Jan uar y , 2000) 7 7 6 7 9 8 9 7 3 4 4 1 2 5 5 10 11 1 3 12 15 14 ITEM NO . P ART NO . DESCRIPTION QTY . 1. SK2346100 ACTUA TOR ASSY ., COMPLETE WITH ITEM 2 . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE003242 ACTUA TOR ASSY ., WITH MANUAL OVERRIDE, COMPLETE WITH ITEMS 2 & 3 . . .1 2. SK23 ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 14

    New (added February 2005) KE600452 (Strainer) FI00351 (Bushing) FI05318-1 (Elbow , hose barb) ITEM NO . P ART NO . DESCRIPTION QTY . 1 2379100 HYDRAULIC ADAPTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2 2379600 HYDRAULIC HOSE ASSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 15

    ITEM NO . P ART NO . DESCRIPTION QTY . 1 2474101 POWER SWITCH (240V , USED AFTER FEBRUARY 2001) . . . . . . . . . . . . . . . . . . . . . .1 2474100 POWER SWITCH (USED AFTER FEBRUARY 2001) . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2343500 POWER SWITCH (USED PRIOR TO FEBRUAR Y 2001) . . . . . . . . . . . . . . . . . . . . . . . .1 2 234 ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 16

    ITEM NO . P ART NO . DESCRIPTION QTY . 1. SE00119 T HERM OSTA T BOAR D ASSEMBLY (INCLUDES 2 - 14) 1 2. SK2142002 TEMPERA TURE SENSOR BOARD 1 3. SK2159300 INSULA TOR, THERMOST A T 1 4. SK2498399 P OTEN TIO ME T ER SHAFT ASSEMBLY (INCLUDES 5-10) 1 5. SK2167200 RET AINING RING, SP-NR #R1000-25 1 6. SK2167100 W ASHER, BOWED/SPRING 1 7. SK2167300 P ANEL ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 17

    ITEM NO . P ART NO . DESCRIPTION QTY . 1 KE53838-32 TRANSFORMER - POWER TIL T - 110-120V/60 . . . . . . . . . . . . . . . . . . . . . . . . .1 KE53838-31 TRANSFORMER - POWER TIL T - 208-240/60 . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE53838-30 TRANSFORMER - POWER TIL T - 208-240/50 . . . . . . . . . . . . . . . . . . . . . . . . . .1 K ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 18

    ITEM NO. P ART NO. DESCRIPTION QTY . 1 KE55069-7 HI-LIMIT 1 2 2353900 BULB CLAMP 1 3 2354099 BULB SHIELD ASSY 1 4 F95 NUT 1 5 2345100 RTD SENSOR 1 6 2344900 SHIELD LINER 1 7 2345000 SHIELD 1 PLA TE ASSEMBL Y (used prior to January , 2000) ITEM NO. P ART NO. DESCRIPTION QTY . 1 F A21053 LOCK NUT 1/2-13 S.S. . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 19

    SPRING ASSEMBL Y ITEM NO . P ART NO . DESCRIPTION QTY . 1 2452300 SPRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2 2381700 TURNBUCKLE BODY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 3 2374900 CONNECTING ROD R/H ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 20

    ITEM NO . P ART NO . DESCRIPTION QTY . 1 2359300 BACK TOP MOUNTING BRACKET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2 2360101 REAR COMBUSTION SEAL - 40 GAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2360100 REAR COMBUSTION SEAL - 30 GAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 21

    ITEM NO . P ART NO . DESCRIPTION QTY . 1 2373100 BURNER (NA T . GAS) . . . . . . . . . . . . . . . . . . . . . . . . . . .7 for 30 gal., 10 for 40 gal. KE02410 BURNER (LP GAS) . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 for 30 gal., 10 for 40 gal. 2 KE55277-1 ORIFICE, (NA T . GAS), 2000 FT . . . . . . . . . . . . . . . . . . .7 for 30 ...

  • Cleveland Open Base & Modular Gas Skillet SGL-30-TR - page 22

    N OT E : ANY MAINTENANCE OR SERVICE INVOL VING DISSASSEMBL Y OF COMPONENTS SHOULD BE MADE BY A QUALIFIED SERVICE TECHNICIAN. ENSURE GAS, ELECTRICAL AND W A TER SUPPL Y (IF APPLICABLE) TO THE APPLIANCE ARE SHUT OFF Y ou have purchased the finest commer cial cooking equipment available anywhere. Like any other fine, precision built piece of equipment ...

Производитель Cleveland Категория Fryer

Документы, которые мы получаем от производителя устройства Cleveland Open Base & Modular Gas Skillet SGL-30-TR мы можем разделить на несколько групп. Это в частности:
- технические чертежи Cleveland
- инструкции обслуживания Open Base & Modular Gas Skillet SGL-30-TR
- паспорта изделия Cleveland
- информационные брошюры
- энергетические этикетки Cleveland Open Base & Modular Gas Skillet SGL-30-TR
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Cleveland Open Base & Modular Gas Skillet SGL-30-TR.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Cleveland Open Base & Modular Gas Skillet SGL-30-TR, инструкции обслуживания, короткие инструкции или инструкции пользователя Cleveland Open Base & Modular Gas Skillet SGL-30-TR. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Cleveland Open Base & Modular Gas Skillet SGL-30-TR.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Cleveland Open Base & Modular Gas Skillet SGL-30-TR, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Cleveland Open Base & Modular Gas Skillet SGL-30-TR пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Cleveland Open Base & Modular Gas Skillet SGL-30-TR.

Полная инструкция обслуживания Cleveland, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Cleveland Open Base & Modular Gas Skillet SGL-30-TR - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Cleveland Open Base & Modular Gas Skillet SGL-30-TR, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Cleveland Open Base & Modular Gas Skillet SGL-30-TR, которое найдем в данном документе
3. Советы по использованию основных функций устройства Cleveland Open Base & Modular Gas Skillet SGL-30-TR - которые должны облегчить нам первые шаги во время использования Cleveland Open Base & Modular Gas Skillet SGL-30-TR
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Cleveland Open Base & Modular Gas Skillet SGL-30-TR
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Cleveland Open Base & Modular Gas Skillet SGL-30-TR в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Cleveland Open Base & Modular Gas Skillet SGL-30-TR?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Cleveland Open Base & Modular Gas Skillet SGL-30-TR, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Cleveland Open Base & Modular Gas Skillet SGL-30-TR со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)