  • Fluke Fluke 16 - page 1

    PN 644226 July, 1997 Rev.1, 3/99 © 1997,1999 Fluke Corporation, Al l rights reserved. Printed in U .S.A. All p r oduct names are trademarks of their respective companies. 1 ® 16 Multimeter with Temperature Calibration Information W Warning To avoid electrical shock, remove test leads and any input signals from the Meter before opening the case. C ...

  • Fluke Fluke 16 - page 2

    16 Multimeter with Temperature 2 Accuracy specifications are given as follows: ±([% of reading] + [number of least significant digits]). Table 1. Specifications (cont) Function Range Resolution Accuracy f (50 to 400 Hz) 4000 mV 1 4.000 V 40.00 V 300.0 V 400.0 V 600.0 V 1 mV 0.001 V 0.01 V 0.1 V 0.1 V 1 V ±(1.9%+3) ±(1.9%+3) ±(1.9%+3) NA ±(1.9% ...

  • Fluke Fluke 16 - page 3

    Specifications 3 Table 1. Specifications (cont) Function Overload Protection 1 Input Impedance (Nominal) Common Mode Rejection Ratio (1 k Ω Unbalanced) 2 Normal Mode Rejection 2 f 600 V dc >5 M Ω <100 pF 2 Automatic Selection and LoZ = >2 k Ω <200 pF (ac coupled) 3 >60 dB at dc 50 Hz or 60 Hz E 600 V dc >10 M Ω <100 pF ...

  • Fluke Fluke 16 - page 4

    16 Multimeter with Temperature 4 Disassembly and Reassembly Referring to Figure 1, disassemble the Meter as follows. A Phillips-head screwdriver and small flat-blade screwdriver are required. 1. Remove the test leads and set the rotary knob to OFF. 2. Remove the Phillips-head screws from the case bottom. 3. Separate the case top from the case botto ...

  • Fluke Fluke 16 - page 5

    Recommended Test Equipment 5 Case, Top Decal Switch Assembly Actuator, Switch Main PCA Shield, Bottom Foot LCD Conn. Elastomeric Conn. Elastomeric LCD to PCA Support, Switch Assembly Battery Shock Absorber Case, Bottom Screw, THD Form, PH.P.STL, 5-14 x .750 ig3f.eps Figure 1. Model 16 Disassembled Unit ...

  • Fluke Fluke 16 - page 6

    16 Multimeter with Temperature 6 1 2 3 Snap Snap Snaps ig2f.eps Figure 2. Removing and Reinserting the Printed Circuit Assembly ...

  • Fluke Fluke 16 - page 7

    Performance Test 7 Performance Test W Warning To avoid electric shock, do not execute the performance tests procedures unless the Meter is fully assembled. To ensure that the Meter is working properly and performs to specifications, use the following procedures. If the Meter fails this test, it needs calibration adjustment or repair. Multimeter Not ...

  • Fluke Fluke 16 - page 8

    16 Multimeter with Temperature 8 Table 3. Performance Tests Test No. Meter Range Input To Meter Switch Position Display Minimum Display Maximum 1 2 3 4 5 6 7 8 9 1 10 4.000 V ac 4.000 V ac, MIN MAX 4.000 V ac 4.000 V ac 4.000 V ac 4.000 V ac 40.00 V ac 40.00 V ac 400.0 V ac 600 V ac 0 V 0 V 10 mV, 50 Hz 10 mV, 400 Hz 3.5 V, 50 Hz 3.5 V, 400 Hz 35 V ...

  • Fluke Fluke 16 - page 9

    Calibration Adjustments 9 + + 5700A Ice Bath AK-80 Banana Plug Temperature Yellow Red Copper 0 ig6f.eps Figure 3. Performance Test for Temperature + _ 9V BATTERY + Clip to Base Contacts Adjust R4 for 3.997-4.003V DC Input Receptacles + ig1f.eps Figure 4. Calibration Adjustment for DC Voltage ...

  • Fluke Fluke 16 - page 10

    16 Multimeter with Temperature 10 Temperature Note Adjust DC voltage (R4) before adjusting temperature (R38). The following describes three temperature calibration procedures: • Calibrating at room temperature. Use this procedure if it is not necessary to optimize the Meter’s performance. • Calibrating in an ice bath. Use this procedure to op ...

  • Fluke Fluke 16 - page 11

    Replacement Parts 11 ! CAL ENABLE 10A 100 mA 1000V 750V MAX ALL INPUTS 1kV MAX 500mA F 250V POWER AUTO 2ND MN MX RATE dB REL LOCAL THRESH ADDR BAUD HOLD LO HI COMP A A V FREQ DUAL DISPLAY MULTIMETER 45 V REF# REF V COM FUSED 80T-150U + _ 9V BATTERY + + R38 Clip to Base Contacts V m ig4f.eps Figure 5. Calibration Adjustment for Temperature Using the ...

  • Fluke Fluke 16 - page 12

    16 Multimeter with Temperature 12 ...

Fabbricante Fluke Categoria Universal Remote

I documenti che otteniamo dal fabbricante del dispositivoFluke Fluke 16 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Fluke
- manuali per l’uso 16
- schede prodotto Fluke
- opuscoli
- o etichette energetiche Fluke Fluke 16
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Fluke Fluke 16.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Fluke Fluke 16, manuali di manutenzione, brevi manuali o manuali utente Fluke Fluke 16. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Fluke Fluke 16.

Manuali per l’uso simili

Manuale completo del dispositivo Fluke Fluke 16, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Fluke Fluke 16 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Fluke Fluke 16.

Il manuale per l’uso completo Fluke, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Fluke Fluke 16 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Fluke Fluke 16, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Fluke Fluke 16 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Fluke Fluke 16 - che ci dovrebbe aiutare nei primi passi durante l'uso Fluke Fluke 16
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Fluke Fluke 16
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Fluke Fluke 16 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Fluke Fluke 16?

Utilizza il modulo sottostante

Se non hai risolto il problema con Fluke Fluke 16 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Fluke Fluke 16 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)