    USER GUIDE AND SPECIFICA TIONS USB-9211/9211A 4-Channel, 24-Bit Thermocouple Input Devices This user guide describes how to use the National Instruments USB-9211/9211A devices and lists the specifications. Introduction The NI USB-9211/9211A data acquisition d evice pro vides a USB interface for four channels of 24-bit thermoco uple inputs with inte ...

  • National Instruments 9211 - page 2

    USB-9211/9211A User Guid e and Specifications 2 ni.com Dimensions Figure 2 shows the USB-9211/9211A devi ce dimensions. Figure 2. USB-9211/9211A Series Devices in Inches (Millimeters) Safety Guidelines Operate the USB-9211/9211A only as described in these operating instructions. Note Although the NI 9211 module may have more stringent certification ...

  • National Instruments 9211 - page 3

    © National Instruments Cor poration 3 USB-9211/9211A User Guide and Specifications Safety Guidelines for Hazardous Vo ltages If hazardous voltages are connected to the module, take the following precautions. A hazardous vo ltage is a voltage greater than 42.4 V pk or 60 VDC to earth ground. Caution Ensure that hazardous v oltage wiring is performe ...

  • National Instruments 9211 - page 4

    USB-9211/9211A User Guid e and Specifications 4 ni.com Related Documentation If your device uses NI-D A Qmx Base, refer to ni.com to do wnload the software. Installing the USB-9211/9211A Device Installing the Software Before installing the device, you must install the software you plan to use with the device. Refer to the Software section of this m ...

  • National Instruments 9211 - page 5

    © National Instruments Cor poration 5 USB-9211/9211A User Guide and Specifications 3. Align the I/O module with the carrier, as sho wn in Figure 3. Figure 3. Module Installation 4. Squeeze the latches and insert the NI 9211 module into the carrier . 5. Press firmly on the connector side of the NI 9211 module until the latches lock the module into ...

  • National Instruments 9211 - page 6

    USB-9211/9211A User Guid e and Specifications 6 ni.com Mounting the USB-9211 /9211A to a Panel Threaded inserts are located in the USB-921 1/9211A for mounting it to a panel. Refer to Figure 5 for dimensions. Figure 5. Module Dimensions Connecting the USB-9211/ 9211A to a Computer Plug one end of the USB cable into th e USB-9211/9211A and the other ...

  • National Instruments 9211 - page 7

    © National Instruments Cor poration 7 USB-9211/9211A User Guide and Specifications Wiring the USB-9211/9211A The USB-9211/9211 A has a 10-terminal, detachabl e high voltage screw terminal enclosure that provides connections for four therm ocouple input channels. Each channel has a terminal to whi ch you can connect the positive lead of the thermoc ...

  • National Instruments 9211 - page 8

    USB-9211/9211A User Guid e and Specifications 8 ni.com Refer to T able 3 for the termin al assignments for each channel. Assembling the High V oltage Screw T erminal Backshell The high voltage screw terminal back shell must be instal led when using hazardous voltages (>42.4 V pk , 60 VDC). Refer to Figure 7 while completing the following steps: ...

  • National Instruments 9211 - page 9

    © National Instruments Cor poration 9 USB-9211/9211A User Guide and Specifications Figure 7. High V oltage Screw T erminal Backsh ell USB-9211/9211A Circuitr y The USB-9211/9211A channels share a common gro und that is isolated from the chassis and the host comput er. Each channel has an impedance between the TC + and COM terminals and between the ...

  • National Instruments 9211 - page 10

    USB-9211/9211A User Guide and Specifications 10 ni.com Figure 8. Input Cir cuitry for One Channel If thermocouples are connected to the USB-921 1/9211A, the gain and of fset errors resulting from the so ur ce impedance of the thermocouples are negligible for most applications. Othe r voltage sources with a higher source impedance can introduce mo r ...

  • National Instruments 9211 - page 11

    © National Instruments Corporation 11 USB- 9211/9211A User Gu ide and Specifications Measurement Accuracy fo r the Different T ypes of Thermocouples Figures 9, 10, 11, 12, and 13 show the typical and maximum errors for the different thermocouple types when used with the USB-9211/9211A over the full temperature range. The figure s also s how the ma ...

  • National Instruments 9211 - page 12

    USB-9211/9211A User Guide and Specifications 12 ni.com Figure 10. T ype E and T Errors Figure 11. T ype J and N Errors –200 0 200 400 600 800 1000 0 2 3 4 Max ov er T emp Range with A utozero Max at Room T emp Range without A utozero T yp ov er T emp Range with Autozero Error ( ° C) Measured T emperature ( ° C) 1 –200 0 200 400 600 800 1000 1 ...

  • National Instruments 9211 - page 13

    © National Instruments Corporation 13 USB- 9211/9211A User Gu ide and Specifications Figur e 12. T ype K Errors Figure 13. T ype R and S Errors Cold-Junction T emperatur e Measurement Accuracy Heat from other nearby h eat sources can cause errors in thermocouple measurements by heating up the term inal s so that they are at a different temperature ...

  • National Instruments 9211 - page 14

    USB-9211/9211A User Guide and Specifications 14 ni.com Minimizing Thermal Gradients Thermocouple wire can be a significan t source of thermal gradients if it conducts heat or cold directly to terminal j unctions. To min imize these errors, follow these guidelines: • Use small-gauge thermocouple wire. Smaller wire transfers less heat to or from th ...

  • National Instruments 9211 - page 15

    © National Instruments Corporation 15 USB- 9211/9211A User Gu ide and Specifications Cold-junction compensation sensor accuracy 0 to 60 °C ...................... .................. 0.6 °C (1.1 °F) typ, 1.3 °C (2.3 °F) max Conversion time ...................... ... ............ 70 ms per channel; 420 ms total for all ch annels including the au ...

  • National Instruments 9211 - page 16

    USB-9211/9211A User Guide and Specifications 16 ni.com Offset error from source impedance ...... . 0.05 µ Vt y p ,0 . 0 7 µ Vm a x p e r Ω source impedance due to input current Power Requirements Current consumption from USB .............500 mA, max Suspend mode ................ ................. .2.5 mA, max Bus Interface USB specification USB ...

  • National Instruments 9211 - page 17

    © National Instruments Corporation 17 USB- 9211/9211A User Gu ide and Specifications V oltages Connect only voltages that are within these limits. Channel-to-COM .................... ............... ± 30 V max, Measurement Category I Measurement Category I is for meas urements performed on circuits not directly connected to the electrical di stri ...

  • National Instruments 9211 - page 18

    USB-9211/9211A User Guide and Specifications 18 ni.com Maximum altitude ................. ..................2,000 m (at 25 °C ambient temperature) Pollution Degree (IEC 60664) .... ............2 Electromagnetic Compatibility Emissions ...................... ................. .........EN 55011 Class A at 10 m FCC Part 15A above 1 GHz Immunity ..... ...

  • National Instruments 9211 - page 19

    National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for m ore inform ation about Natio nal Instruments trademarks. Other product and compan y names mentioned herein are t rademarks or trade names of their respective companie s. For patents coveri ng Na ...

Fabbricante National Instruments Categoria Computer Drive

I documenti che otteniamo dal fabbricante del dispositivoNational Instruments 9211 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici National Instruments
- manuali per l’uso 9211
- schede prodotto National Instruments
- opuscoli
- o etichette energetiche National Instruments 9211
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso National Instruments 9211.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione National Instruments 9211, manuali di manutenzione, brevi manuali o manuali utente National Instruments 9211. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto National Instruments 9211.

Manuale completo del dispositivo National Instruments 9211, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare National Instruments 9211 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti National Instruments 9211.

Il manuale per l’uso completo National Instruments, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale National Instruments 9211 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice National Instruments 9211, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per National Instruments 9211 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo National Instruments 9211 - che ci dovrebbe aiutare nei primi passi durante l'uso National Instruments 9211
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del National Instruments 9211
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio National Instruments 9211 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su National Instruments 9211?

Utilizza il modulo sottostante

Se non hai risolto il problema con National Instruments 9211 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con National Instruments 9211 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)