  • Directed Electronics 6000 - page 1

    This de vice complies with par t 15 of FCC rules. Operation is subject to the f ollowing two conditions: (1) This de vice ma y not cause harmful interference , and (2) This de vice m ust accept any interf erence receiv ed, including inter- f erence that ma y cause undesired operation. CA UTION: Changes or modifications not e xpressly approv ed b y ...

  • Directed Electronics 6000 - page 2

    2 © 1996 Directed Electronics, Inc. T able of C ontents System Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Y our W arranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 What Is Included . . . . . . . . . . . . . . ...

  • Directed Electronics 6000 - page 3

    3 © 1996 Directed Electronics, Inc. What is included ■ The control module ■ A pair of two-b utton transmitters ■ A Stinger ® DoubleGuard ® dual-output shock sensor ■ The Re venger ® Soft Chir p ® six-tone programmab le siren ■ The red Status LED indicator light ■ A push-button V alet ® s witch ■ Y our warranty card ■ F ailSafe ...

  • Directed Electronics 6000 - page 4

    4 © 1996 Directed Electronics, Inc. T ransmitter Channels Channel I The arm/disar m and panic functions, are usually controlled b y Button I. Channel II The Silent Mode ™ /trunk release function, is usually controlled by Button II. Silent Mode ™ and Remote V alet ® work by pressing b utton II for less than one second. T r unk release requires ...

  • Directed Electronics 6000 - page 5

    5 © 1996 Directed Electronics, Inc. Using Y our S ystem Arming Y ou can tur n on, or arm , the system b y pressing button I of y our transmitter f or one second. When the system arms, y ou will hear a short siren sound, or chirp , and see the parking lights flash once. If the v ehicle’ s power door loc ks are controlled by the system, the doors ...

  • Directed Electronics 6000 - page 6

    6 © 1996 Directed Electronics, Inc. to disar m the system with y our transmitter if you inadv er tently open the door while the system is ar med, while still pro viding instant response (e v en if the door is immediately closed). • T ur ning on the ignition ke y will tr ip the same two-stage response as opening a door . • The optional starter ...

  • Directed Electronics 6000 - page 7

    7 © 1996 Directed Electronics, Inc. to check the v ehicle visually . The tr igger will stop , but the v ehicle will remain protected. T o disar m with the transmitter during a trigger , press Button I on your tr ansmitter . The siren will stop sounding. Ne xt press Button I once more and the system will chir p four or fiv e times (repor ting the t ...

  • Directed Electronics 6000 - page 8

    8 © 1996 Directed Electronics, Inc. V alet ® Mode Y ou can prev ent your system from automatically arming and tr iggering by using V alet ® Mode. This is ver y useful when w ashing the vehicle or having it ser viced. In V alet ® Mode, the system will not arm, ev en with the transmitter , but all con venience functions (door loc ks, trunk releas ...

  • Directed Electronics 6000 - page 9

    9 © 1996 Directed Electronics, Inc. trigger the system while it is being bypassed, the 60-minute b ypass period will star t ov er . This ensures that a sensor that continuously triggers will remain bypassed. Doors are cov ered by NPC ™ diff erently: If the alarm is tr iggered b y an open door f or three full cycles (one and one half minutes), th ...

  • Directed Electronics 6000 - page 10

    10 © 1996 Directed Electronics, Inc. Diagnostics The microprocessor at the hear t of your system is constantly monitoring all of the s witches and sensors connected to it. It detects any f aulty switches and sensors and pre vents them from disab ling the entire system. The micro- processor will also record and repor t any triggers that occurred du ...

  • Directed Electronics 6000 - page 11

    11 © 1996 Directed Electronics, Inc. Table of Zones The zone number is the number of LED flashes used by the system to iden- tify that input. The standard input assignments are listed below , along with spaces to write in any optional sensors or s witches you ha ve had installed. NOTE: If the Warn A way ® response is triggered, the LED will not r ...

  • Directed Electronics 6000 - page 12

    12 © 1996 Directed Electronics, Inc. C ode Hopping ™ Explained The receiver and tr ansmitters each use a mathematical formula called an algorithm to change their code each time the transmitter is used. This tech- nology has been de v eloped to increase the security of the unit. The control unit knows what the ne xt codes should be. This helps to ...

  • Directed Electronics 6000 - page 13

    13 © 1996 Directed Electronics, Inc. NOTE: If the door is open when the ignition is turned on, the doors will not lock. • P anic mode enabled /disab led with the ignition on. (Some states hav e laws against siren capability in a moving v ehicle). • A utomatic Engine Disable (AED) on or off . The pur pose of the feature is to pro- tect the vehi ...

  • Directed Electronics 6000 - page 14

    14 © 1996 Directed Electronics, Inc. V ehicle R ecovery S ystem (V RS ® )* The optional V ehicle Recovery System feature is designed to ensure that an y unauthorized user of your v ehicle (ev en if using your ke ys and remote con- trol) will not be able to permanently separate you from y our vehicle . The VRS ® f eature cannot pre vent a carjac ...

  • Directed Electronics 6000 - page 15

    15 © 1996 Directed Electronics, Arming the VR S ® T o ar m the VRS ® , push the b utton once. This can be done before driving or while driving the vehicle. Once the system is ar med, it will go into its triggered sequence (see below) if an y door is opened and closed. If you are f orced from the v ehicle the system will trigger as the door will ...

  • Directed Electronics 6000 - page 16

    F rom this point on, when the ignition k e y is turned off, the VRS ® will immediately turn on the F ailSafe ® starter kill. This will pre- vent the v ehicle from being restar ted, thus immobilizing it at that spot. Three minutes after the constant siren output begins, the flashing parking lights and the siren will stop. The star ter kill will re ...

  • Directed Electronics 6000 - page 17

    17 © 1996 Directed Electronics, Inc. Gloss ary of T erms Control Unit The “brain” of y our system. Usually hidden under neath the dash area of the vehicle . It houses the microprocessor which monitors y our vehi- cle and controls all of the alarm's functions. FailSaf e ® Starter Kill An automatic switch controlled b y the secur ity syste ...

  • Directed Electronics 6000 - page 18

    18 © 1996 Directed Electronics, Inc. Security & C onvenience Expansions Here we ha v e listed only some of the many e xpansion options av ailable . Please consult your dealer f or a complete explanation of all the options a vail- able to y ou. Field Disturbance Sensor : An invisible dome of co verage is estab lished by the 508T “radar” sen ...

  • Directed Electronics 6000 - page 19

    19 QU ICK RE FE RE NCE OPE RA TING C ARD : Arming ▼ Y ou can turn on, or ar m, the system b y pressing Button I of your transmitter f or one second. When the system arms, you will hear a shor t chir p, and see the parking lights flash once . Arming While Driving ▼ Press Button I on y our transmitter while the v ehicle is r unning. The system wi ...

  • Directed Electronics 6000 - page 20

    S ystem Ref er ence Car d Directed Electronics, Inc. 2560 Progress Street Vista, CA 92083-8491 © Copyright 1990, 1996 Directed Electronics, Inc. - All rights reserved G437 12/96 The company behind DEI ® is Directed Electr onics, Inc. Since its inception, the company known as Directed Electronics, Inc. (DEI ® ) has had one pur pose - to br ing th ...

Fabbricante Directed Electronics Categoria Stud Sensor

I documenti che otteniamo dal fabbricante del dispositivoDirected Electronics 6000 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Directed Electronics
- manuali per l’uso 6000
- schede prodotto Directed Electronics
- opuscoli
- o etichette energetiche Directed Electronics 6000
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Directed Electronics 6000.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Directed Electronics 6000, manuali di manutenzione, brevi manuali o manuali utente Directed Electronics 6000. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Directed Electronics 6000.

Manuale completo del dispositivo Directed Electronics 6000, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Directed Electronics 6000 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Directed Electronics 6000.

Il manuale per l’uso completo Directed Electronics, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Directed Electronics 6000 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Directed Electronics 6000, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Directed Electronics 6000 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Directed Electronics 6000 - che ci dovrebbe aiutare nei primi passi durante l'uso Directed Electronics 6000
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Directed Electronics 6000
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Directed Electronics 6000 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Directed Electronics 6000?

Utilizza il modulo sottostante

Se non hai risolto il problema con Directed Electronics 6000 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Directed Electronics 6000 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)