    7000 SERIES GAS OVENS MODEL 7018A1 ML-104491 7088A1 ML-104492 7888A1 ML-104493 7086A1 ML-104494 7016A1 ML-104495 7066A1 ML-104496 7019A1 ML-104497 7099A1 ML-104498 7999A1 ML-104499 7096A1 ML-104500 7098A1 ML-104501 7988A1 ML-104502 7998A1 ML-104503 MODEL 7019A1 VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791 FORM 3 ...

  • Vulcan-Hart 7016A1 ML-104495 - page 2

    — 2 — IMPORT ANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OB ...

  • Vulcan-Hart 7016A1 ML-104495 - page 3

    — 3 — T ABLE OF CONTENTS MODEL 7000 SERIES OVEN CONFIGURATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Bake Ovens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Roast Ovens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Vulcan-Hart 7016A1 ML-104495 - page 4

    — 4 — MODEL 7000 SERIES BAKE OVEN CONFIGURATIONS 7086A1 7016A1 7066A1 7018A1 7088A1 7888A1 ...

  • Vulcan-Hart 7016A1 ML-104495 - page 5

    — 5 — MODEL 7000 SERIES ROAST OVEN CONFIGURATIONS 7019A1 7099A1 Model 7999A1 not shown. MODEL 7000 SERIES COMBINATION BAKE & ROAST OVEN CONFIGURATIONS 7096A1 7098A1 7988A1 Model 7998A1 not shown. ...

  • Vulcan-Hart 7016A1 ML-104495 - page 6

    — 6 — Installation, Operation and Care of VULCAN 7000 SERIES BAKE AND ROAST OVEN KEEP THESE INSTRUCTIONS GENERAL The manufacturer suggests that you thoroughly read this entire manual and carefully follow all of the instructions provided. Your Vulcan 7000 Series Bake and Roast Oven is produced with quality workmanship and material. Proper instal ...

  • Vulcan-Hart 7016A1 ML-104495 - page 7

    — 7 — INST ALLA TION UNPACKING Immediately after unpacking, check for possible shipping damage. If the oven is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery. There may be a large label located on the front of the oven which reads, "Remove this label before operation." To remove lab ...

  • Vulcan-Hart 7016A1 ML-104495 - page 8

    — 8 — ASSEMBLY Legs If oven is to be mounted on legs, assemble legs to the oven. Tip oven back and install two front legs with bolts through bottom of oven base frame. Tip oven forward, block up back and install rear legs. Remove shipping harnesses from the burner area. If oven is to be placed on legs, do not remove burner shipping harness unti ...

  • Vulcan-Hart 7016A1 ML-104495 - page 9

    — 9 — These ovens can be mounted interchangeably starting with the largest section on the bottom. The factory shipping tags will be marked accordingly. For the purpose of stacking positions, the suffix letter at the end of the model number is your guide: T — Top Section M — Middle Section B — Bottom Section If you do not have one of the a ...

  • Vulcan-Hart 7016A1 ML-104495 - page 10

    — 10 — GAS CONNECTIONS All gas supply connections and any pipe joint compound used must be resistant to the action of propane gases. The oven is equipped for a 3 / 4 " gas pipe connection. Pipe gas supply to the oven. Make sure the pipes are clean and free of obstructions, dirt and piping compound. When connecting the gas supply to the ove ...

  • Vulcan-Hart 7016A1 ML-104495 - page 11

    — 11 — ELECTRICAL CONNECTIONS WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES. WARNING: APPLIANCES EQUIPPED WITH A FLEXIBLE ELECTRIC SUPPLY CORD ARE PROVIDED WITH A THREE-PRONG GROUNDING PLUG. IT IS IMPERATIVE THAT THIS PLUG BE CONNECTED I ...

  • Vulcan-Hart 7016A1 ML-104495 - page 12

    — 12 — OPERA TION WARNING: THE OVEN AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING OR SERVICING THE OVEN. CONTROLS (Fig. 4) Burner Valve — when opened, allows gas to flow to the oven burner. To open valve, turn knob counterclockwise; to close valve, turn knob clockwise. Ignition Button — used to reset the oven pilot. To operate, p ...

  • Vulcan-Hart 7016A1 ML-104495 - page 13

    — 13 — LIGHTING AND SHUTTING DOWN PILOT 1. Turn on main gas supply. 2. Turn burner valve ON and purge air from line. Turn burner valve OFF. 3. Wait 5 minutes, then turn burner valve ON and depress ignition button. Using a lit taper, ignite oven pilot (Fig. 5). Continue to hold button in for approximately 30 seconds, then release. 4. If pilot go ...

  • Vulcan-Hart 7016A1 ML-104495 - page 14

    — 14 — PREHEATING Set thermostat knob to desired temperature and allow oven to preheat for approximately 15 minutes before loading. LOADING OVEN 1. When using 2- or 4-deck sections that have one control for two compartments, load both compartments simultaneously. If a quantity sufficient for only one compartment is to be baked, load only the co ...

  • Vulcan-Hart 7016A1 ML-104495 - page 15

    — 15 — CLEANING WARNING: TURN OVEN OFF AND UNPLUG THE ELECTRICAL CORD (IF APPLICABLE) BEFORE CLEANING. Clean interior and exterior of oven daily with warm water and detergent solution. Rinse thoroughly and wipe dry with a soft clean cloth. Oven Inspection Window (Optional) The oven inspection window may be cleaned with an oven cleaner compound ...

  • Vulcan-Hart 7016A1 ML-104495 - page 16

    — 16 — MAINTENANCE WARNING: THE OVEN AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING OR SERVICING THE OVEN. REPLACING OPTIONAL LAMPS WARNING: TURN OVEN OFF AND UNPLUG ELECTRICAL CORD BEFORE REPLACING LAMPS. Lamps are located in the top of the oven, centered at the back. 1. Remove (4) 10-24 sheet metal screws, remove glass, and unscrew ...

Fabbricante Vulcan-Hart Categoria Oven

I documenti che otteniamo dal fabbricante del dispositivoVulcan-Hart 7016A1 ML-104495 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Vulcan-Hart
- manuali per l’uso 7016A1 ML-104495
- schede prodotto Vulcan-Hart
- opuscoli
- o etichette energetiche Vulcan-Hart 7016A1 ML-104495
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Vulcan-Hart 7016A1 ML-104495.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Vulcan-Hart 7016A1 ML-104495, manuali di manutenzione, brevi manuali o manuali utente Vulcan-Hart 7016A1 ML-104495. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Vulcan-Hart 7016A1 ML-104495.

Manuali per l’uso simili

Manuale completo del dispositivo Vulcan-Hart 7016A1 ML-104495, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Vulcan-Hart 7016A1 ML-104495 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Vulcan-Hart 7016A1 ML-104495.

Il manuale per l’uso completo Vulcan-Hart, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Vulcan-Hart 7016A1 ML-104495 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Vulcan-Hart 7016A1 ML-104495, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Vulcan-Hart 7016A1 ML-104495 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Vulcan-Hart 7016A1 ML-104495 - che ci dovrebbe aiutare nei primi passi durante l'uso Vulcan-Hart 7016A1 ML-104495
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Vulcan-Hart 7016A1 ML-104495
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Vulcan-Hart 7016A1 ML-104495 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Vulcan-Hart 7016A1 ML-104495?

Utilizza il modulo sottostante

Se non hai risolto il problema con Vulcan-Hart 7016A1 ML-104495 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Vulcan-Hart 7016A1 ML-104495 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)